1.
Healthc Technol Lett ; 3(4): 269-272, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28008362

RESUMO

The purpose of this Letter was to investigate the influence of real-time verbal feedback to optimise push arc during over ground manual wheelchair propulsion. Ten healthy non-wheelchair users pushed a manual wheelchair for a distance of 25 m on level paving, initially with no feedback and then with real-time verbal feedback aimed at controlling push arc within a range of 85°-100°. The real-time feedback was provided by a physiotherapist walking behind the wheelchair, viewing real-time data on a tablet personal computer received from the Sensewheel, a lightweight instrumented wheelchair wheel. The real-time verbal feedback enabled the participants to significantly increase their push arc. This increase in push arc resulted in a non-significant reduction in push rate and a significant increase in peak force application. The intervention enabled participants to complete the task at a higher mean velocity using significantly fewer pushes. This was achieved via a significant increase in the power generated during the push phase. This Letter identifies that a lightweight instrumented wheelchair wheel such as the Sensewheel is a useful adjunct to wheelchair skills training. Targeting the optimisation of push arc resulted in beneficial changes in propulsion technique.

2.
J Orthop Res ; 30(6): 998-1003, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22095751

RESUMO

Loosening of glenoid components in TSA is a main cause of failure. In reverse anatomy TSA designs used for unstable joints, fixation is particularly demanding. Strains developed around the glenoid rim of biomechanical sawbone scapulae implanted with (a) the original fixed-fulcrum Bayley-Walker glenoid prosthesis in current clinical use, and (b) a revised version with conical cross-section, were compared. The conical shape of the revised design was hypothesized to produce greater strains in the glenoid rim than the original tapered screw design. The 2D strain field at three accessible locations around the rim of each scapula was measured with three-element rosette strain gauges for two types of simulated cancellous bone fill under applied physiologically relevant loads. The average strain energy densities around the rim for the conical design were greater than for the original design by a factor of 1.55-2.25 for all loading conditions. Results indicate that a significantly greater proportion of load was directed toward cortical bone in the conical design, thus promoting cortical bone loading.


Assuntos
Artroplastia de Substituição/instrumentação , Cavidade Glenoide/cirurgia , Articulação do Ombro/cirurgia , Artroplastia de Substituição/métodos , Análise de Falha de Equipamento , Cavidade Glenoide/fisiopatologia , Humanos , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Prótese Articular , Falha de Prótese , Articulação do Ombro/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...