1.
Radiat Prot Dosimetry ; 150(1): 1-21, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21890528

RESUMO

A passive neutron-bubble dosemeter (BD), developed by Bubble Technology Industries, has been used for space applications. Both the bubble detector-personal neutron dosemeter and bubble detector spectrometer have been studied at ground-based facilities in order to characterise their response due to neutrons, heavy ion particles and protons. This technology was first used during the Canadian-Russian collaboration aboard the Russian satellite BION-9, and subsequently on other space missions, including later BION satellites, the space transportation system, Russian MIR space station and International Space Station. This paper provides an overview of the experiments that have been performed for both ground-based and space studies in an effort to characterise the response of these detectors to various particle types in low earth orbit and presents results from the various space investigations.


Assuntos
Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Astronave/instrumentação , Radiação Cósmica , Desenho de Equipamento , Análise de Falha de Equipamento , Microbolhas , Nêutrons , Doses de Radiação
2.
Adv Space Res ; 22(4): 501-10, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-11542778

RESUMO

The Mir station has been in a 51.65 degrees inclination orbit since March 1986. In March 1995, the first US astronaut flew on the Mir-18 mission and returned on the Space Shuttle in July 1995. Since then three additional US astronauts have stayed on orbit for up to 6 months. Since the return of the first US astronaut, both the Spektr and Priroda modules have docked with Mir station, altering the mass shielding distribution. Radiation measurements, including the direct comparison of US and Russian absorbed dose rates in the Base Block of the Mir station, were made during the Mir-18 and -19 missions. There is a significant variation of dose rates across the core module; the six locations sampled showed a variation of a factor of nearly two. A tissue equivalent proportional counter (TEPC) measured a total absorbed dose rate of 300 microGy/day, roughly equally divided between the rate due to trapped protons from the South Atlantic Anomaly (SAA) and galactic cosmic radiation (GCR). This dose rate is about a factor of two lower than the rate measured by the thinly shielded (0.5 g cm-2 of Al) operational ion chamber (R-16), and about 3/2 of the rate of the more heavily shielded (3.5 g cm-2 of Al) ion chamber. This is due to the differences in the mass shielding properties at the location of these detectors. A comparison of integral linear energy transfer (LET) spectra measured by TEPC and plastic nuclear track detectors (PNTDs) deployed side by side are in remarkable agreement in the LET region of 15-1000 keV/micrometer, where the PNTDs are fully efficient. The average quality factor, using the ICRP-26 definition, was 2.6, which is higher than normally used. There is excellent agreement between the measured GCR dose rate and model calculations, but this is not true for trapped protons. The measured Mir-18 crew skin dose equivalent rate was 1133 microSv/day. Using the skin dose rate and anatomical models, we have estimated the blood-forming organ (BFO) dose rate and the maximum stay time in orbit for International Space Station crew members.


Assuntos
Radiação Cósmica , Prótons , Monitoramento de Radiação/instrumentação , Atividade Solar , Voo Espacial/instrumentação , Oceano Atlântico , Sistema Hematopoético/efeitos da radiação , Humanos , Transferência Linear de Energia , Doses de Radiação , Proteção Radiológica , Radiometria/instrumentação , Federação Russa , Pele/efeitos da radiação , América do Sul , Astronave/instrumentação , Estados Unidos , United States National Aeronautics and Space Administration , Ausência de Peso
3.
Radiat Meas ; 26(6): 901-16, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11540523

RESUMO

A joint NASA Russia study of the radiation environment inside the Space Shuttle was performed on STS-63. This was the second flight under the Shuttle-Mir Science Program (Phase 1). The Shuttle was launched on 2 February 1995, in a 51.65 degrees inclination orbit and landed at Kennedy Space Center on 11 February 1995, for a total flight duration of 8.27 days. The Shuttle carried a complement of both passive and active detectors distributed throughout the Shuttle volume. The crew exposure varied from 1962 to 2790 microGy with an average of 2265.8 microGy or 273.98 microGy/day. Crew exposures varied by a factor of 1.4, which is higher than usual for STS mission. The flight altitude varied from 314 to 395 km and provided a unique opportunity to obtain dose variation with altitude. Measurements of the average east-west dose variation were made using two active solid state detectors. The dose rate in the Spacehab locker, measured using a tissue equivalent proportional counter (TEPC), was 413.3 microGy/day, consistent with measurements made using thermoluminescent detectors (TLDs) in the same locker. The average quality factor was 2.33, and although it was higher than model calculations, it was consistent with values derived from high temperature peaks in TLDs. The dose rate due to galactic cosmic radiation was 110.6 microGy/day and agreed with model calculations. The dose rate from trapped particles was 302.7 microGy/day, nearly a factor of 2 lower than the prediction of the AP8 model. The neutrons in the intermediate energy range of 1-20 MeV contributed 13 microGy/day and 156 microSv/day, respectively. Analysis of data from the charged particle spectrometer has not yet been completed.


Assuntos
Radiação Cósmica , Prótons , Monitoramento de Radiação/instrumentação , Voo Espacial , Oceano Atlântico , Transferência Linear de Energia , Modelos Teóricos , Doses de Radiação , Proteção Radiológica , Radiometria , Federação Russa , América do Sul , Astronave , Dosimetria Termoluminescente , Estados Unidos , United States National Aeronautics and Space Administration
4.
Radiat Meas ; 26(2): 147-58, 1996 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11539200

RESUMO

A tissue equivalent proportional counter designed to measure the linear energy transfer spectra (LET) in the range 0.2-1250 keV/micrometer was flown in the Kvant module on the Mir orbital station during September 1994. The spacecraft was in a 51.65 degrees inclination, elliptical (390 x 402 km) orbit. This is nearly the lower limit of its flight altitude. The total absorbed dose rate measured was 411.3 +/- 4.41 microGy/day with an average quality factor of 2.44. The galactic cosmic radiation (GCR) dose rate was 133.6 microGy/day with a quality factor of 3.35. The trapped radiation belt dose rate was 277.7 microGy/day with an average quality factor of 1.94. The peak rate through the South Atlantic Anomaly was approximately 12 microGy/min and nearly constant from one pass to another. A detailed comparison of the measured LET spectra has been made with radiation transport models. The GCR results are in good agreement with model calculations; however, this is not the case for radiation belt particles and again points to the need for improving the AP8 omni-directional trapped proton models.


Assuntos
Radiação Cósmica , Transferência Linear de Energia , Modelos Teóricos , Prótons , Atividade Solar , Voo Espacial/instrumentação , Brasil , Nêutrons , Doses de Radiação , Monitoramento de Radiação/instrumentação , Radiometria/instrumentação
5.
Radiat Meas ; 26(1): 17-34, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11539199

RESUMO

A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.


Assuntos
Nêutrons , Prótons , Monitoramento de Radiação/instrumentação , Voo Espacial/instrumentação , Dosimetria Termoluminescente/instrumentação , Oceano Atlântico , Humanos , Cooperação Internacional , Transferência Linear de Energia , Doses de Radiação , Radiometria , Federação Russa , Atividade Solar , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...