Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
2.
BMC Cardiovasc Disord ; 23(1): 8, 2023 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624380

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is recommended to treat paroxysmal and persistent atrial fibrillation (AF). This analysis aimed to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and point-by-point radiofrequency ablation (RFA). METHODS: The discrete event simulation used PVI procedure times from the FREEZE Cohort study to establish the electrophysiology (EP) lab occupancy time. 1000 EP lab days were simulated according to an illustrative German hospital, including 3 PVI cases per day using CBA at one site and RFA at the other. RESULTS: The analysis included 1560 CBA patients and 1344 RFA patients from the FREEZE Cohort. Some baseline patients' characteristics were different between groups (age, AF type, and some concomitant diseases), without being statistically associated to ablation procedure time. Mean procedure time was 122.2 ± 39.4 min for CBA and 160.3 ± 53.5 min for RFA (p < 0.0001). RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the simulated period (1285 h with RFA and 253 h with CBA). 70.7% of RFA lab days included overtime versus 25.7% for CBA. CBA was associated with more days with an additional hour at the end of the EP lab shift compared to RFA (47.8% vs 11.5% days with one hour left, respectively). CONCLUSION: CBA is faster and more predictable than point-by-point RFA, and enables improvements in EP lab efficiency, including: fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage. Clinical trial registration NCT01360008 (first registration 25/05/2011).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Estudos de Coortes , Criocirurgia/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Eletrofisiologia , Resultado do Tratamento , Recidiva
3.
Clin Res Cardiol ; 111(5): 522-529, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34106323

RESUMO

AIM: To compare patient characteristics, safety and efficacy of catheter ablation of supraventricular tachycardia (SVT) in patients with and without structural heart disease (SHD) enrolled in the German ablation registry. METHODS AND RESULTS: From January 2007 until January 2010, a total of 12,536 patients (37.2% with known SHD) were enrolled and followed for at least one year. Patients with SHD more often underwent ablation for atrial flutter (45.8% vs. 20.9%, p < 0.001), whereas patients without SHD more often underwent ablation for atrioventricular nodal reentrant tachycardia (30.2% vs. 11.8%, p < 0.001) or atrioventricular reentrant tachycardia (9.1% vs. 1.6%, p < 0.001). Atrial fibrillation catheter ablation procedures were performed in a similar proportion of patients with and without SHD (38.1% vs. 36.9%, p = 0.21). Overall, periprocedural success rate was high in both groups. Death, myocardial infarction or stroke occurred in 0.2% and 0.1% of patients with and without SHD (p = 0.066). Major non-fatal complications prior to discharge were rare and did not differ significantly between patients with and without SHD (0.5% vs. 0.4%, p = 0.34). Kaplan-Meier mortality estimate at 1 year demonstrated a significant mortality increase in patients with SHD (2.6% versus 0.7%; p < 0.001). CONCLUSION: Patients with and without SHD undergoing SVT ablation exhibit similar success rates and low major complication rates, despite disadvantageous baseline characteristics in SHD patients. These data highlight the safety and efficacy of SVT ablation in patients with and without SHD. Nevertheless Kaplan-Meier mortality estimates at 1 year demonstrate a significant mortality increase in patients with SHD, highlighting the importance of treating the underlying condition and reliable anticoagulation if indicated.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Paroxística , Taquicardia Supraventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cardiopatias/cirurgia , Humanos , Sistema de Registros , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Paroxística/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
4.
Clin Microbiol Infect ; 26(12): 1663-1669, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32822883

RESUMO

OBJECTIVES: In Germany the coronavirus disease 2019 (COVID-19) pandemic situation is unique among large European countries in that incidence and case fatality rate are distinctly lower. We describe the clinical course and examine factors associated with outcomes among patients hospitalized with COVID-19 in Germany. METHODS: In this retrospective cohort study we included patients with COVID-19 admitted to a national network of German hospitals between February 12 and June 12, 2020. We examined demographic characteristics, comorbidities and clinical outcomes. RESULTS: We included 1904 patients with a median age of 73 years, 48.5% (924/1904) of whom were female. The mortality rate was 17% (317/1835; 95% confidence interval (95%CI) 16-19), the rate of admission to the intensive care unit (ICU) was 21% (399/1860; 95%CI 20-23), and the rate of invasive mechanical ventilation was 14% (250/1850: 95%CI 12-15). The most prominent risk factors for death were male sex (hazard ratio (HR) 1.45; 95%CI 1.15-1.83), pre-existing lung disease (HR 1.61; 95%CI 1.20-2.16), and increased patient age (HR 4.11 (95%CI 2.57-6.58) for age >79 years versus <60 years). Among patients admitted to the ICU, the mortality rate was 29% (109/374; 95%CI 25-34) and higher in ventilated (33% [77/235; 95%CI 27-39]) than in non-ventilated ICU patients (23%, 32/139; 95%CI 16-30; p < 0.05). CONCLUSIONS: In this nationwide series of patients hospitalized with COVID-19 in Germany, in-hospital and ICU mortality rates were substantial. The most prominent risk factors for death were male sex, pre-existing lung disease, and greater patient age.


Assuntos
COVID-19/mortalidade , Hospitalização/estatística & dados numéricos , Pandemias/estatística & dados numéricos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , COVID-19/fisiopatologia , Comorbidade , Cuidados Críticos , Feminino , Alemanha/epidemiologia , Mortalidade Hospitalar , Humanos , Incidência , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Respiração Artificial/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais
5.
Clin Res Cardiol ; 108(7): 815-823, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30788620

RESUMO

BACKGROUND: Heart failure (HF) and atrial fibrillation (AF) often coexist, but data on the prognostic value of differing ablation strategies according to left ventricular ejection fraction (LVEF) are rare. METHODS AND RESULTS: From January 2007 until January 2010, 728 patients with HF were enrolled in the multi-center German ablation registry prior to AF catheter ablation. Patients were divided into three groups according to LVEF: HF with preserved LVEF (≥ 50%, HFpEF, n = 333), mid-range LVEF (40-49%, HFmrEF, n = 207), and reduced LVEF (< 40%, HFrEF, n = 188). Ablation strategies differed significantly between the three groups with the majority of patients with HFpEF (83.4%) and HFmrEF (78.4%) undergoing circumferential pulmonary vein isolation vs. 48.9% of patients with HFrEF. The latter underwent ablation of the atrioventricular (AV) node in 47.3%. Major complications did not differ between the groups. Kaplan-Meier survival analysis demonstrated a significant mortality increase in patients with HFrEF (6.1% in HFrEF vs. 1.5% in HFmrEF vs. 1.9% in HFpEF, p = 0.009) that was limited to patients undergoing ablation of the AV node. CONCLUSIONS: Catheter ablation strategies differ significantly in patients with HFpEF, HFmrEF, and HFrEF. In almost 50% of patients with HFrEF AV-node ablation was performed, going along with a significant increase in mortality rate. These results should raise efforts to further evaluate the prognostic effect of ablation strategies in HF patients.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/normas , Insuficiência Cardíaca/cirurgia , Guias de Prática Clínica como Assunto , Sistema de Registros , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Nó Atrioventricular/fisiopatologia , Feminino , Seguimentos , Alemanha/epidemiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento
6.
Europace ; 18(3): 368-75, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26504108

RESUMO

AIMS: First-line ablation prior to antiarrhythmic drug (AAD) therapy is an option for symptomatic paroxysmal atrial fibrillation (PAF); however, the optimal ablation technique, radiofrequency (RF), or cryoballoon (CB) has to be determined. METHODS AND RESULTS: The FREEZE Cohort Study compares RF and CB ablation. Treatment-naïve patients were documented in the FREEZEplus Registry. Periprocedural data and outcome were analysed. From 2011 to 2014, a total of 373/4184 (8.9%) patients with PAF naïve to AAD were identified. Pulmonary vein isolation (PVI) was performed with RF (n = 180) or CB (n = 193). In the RF group, patients were older (65 vs. 61 years, P < 0.01) compared with the CB group. The procedure time was significantly shorter and radiation exposure higher in the CB group. Major adverse events occurred in 1.6% (CB) and 3.7% (RF) of patients (P = 0.22). AF/atrial tachycardia (AT) recurrence until discharge was 4.5% (RF) and 8.5% (CB, P = 0.2). Follow-up (FU) ≥12 months was available in 99 (RF) and 107 (CB) patients. After 1.4 years of FU, freedom from AF/atrial tachycardia (AT) was 61% (RF) and 71% (CB, P = 0.11). In the RF group, more patients underwent cardioversion, and a trend for more repeat ablations was observed. Persistent phrenic nerve palsy was observed in one patient treated by CB. CONCLUSION: First-line ablation for PAF is safe and effective with either RF or CB. The procedure was faster with the CB, but the radiation exposure was higher. Although there was a trend for more recurrences and complications in the RF group, a more favourable risk profile in patients undergoing CB ablation might have biased the results. CLINICALTRIALSGOV IDENTIFIER: NCT01360008.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Frequência Cardíaca , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Doses de Radiação , Exposição à Radiação , Recidiva , Sistema de Registros , Reoperação , Fatores de Risco , África do Sul , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
7.
Europace ; 16(10): 1434-42, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24994074

RESUMO

AIMS: Cryoballoon (CB) ablation with the second-generation cryoballoon (CBG2) seems to be more effective than its predecessor [first-generation cryoballoon (CBG1)], but phrenic nerve palsies were observed more frequently. The aim of this study was to compare the safety and efficacy of CBG1 and CBG2 in a substudy of the prospective multicentre, multinational FREEZE Cohort Study. METHODS AND RESULTS: Periprocedural data were analysed, and a total of 532 patients with paroxysmal atrial fibrillation (AF) were examined (n = 224 for CBG1 and n = 308 for CBG2). Procedure time decreased significantly from 149 to 130 min when comparing CBG1 with CBG2 (P < 0.0001), and pulmonary vein isolation (PVI) was achieved in 97.8 and 97.6% of PVs with CBG1 and CBG2 (P = 0.77), respectively. The need for dual-balloon usage within a procedure dropped (20.1 vs. 9.0%, P < 0.001), and the fluoroscopy time was reduced when operating the CBG2. Atrial fibrillation recurrence rates until discharge were similar (5.0 vs. 5.8%, P = 0.69). Comparable low rates of major complications were observed with both CBs, and there was a non-significant trend for more phrenic nerve palsies. CONCLUSION: Second-generation cryoballoon demonstrated a high rate of acute PVI in a significant faster procedure, which also utilized less radiation exposure and less dual-balloon usage during an average procedure. The safety profile remains favourable with a non-significant trend for more phrenic nerve palsies. If the enhancements lead to a higher clinical benefit has to be determined. The 1-year outcome data from the ongoing FREEZE Cohort Study comparing radiofrequency and CB ablation will shed some light on that issue. CLINICAL TRIALS GOV IDENTIFIER: NCT01360008.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/instrumentação , Idoso , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Segurança do Paciente , Complicações Pós-Operatórias , Estudos Prospectivos , Veias Pulmonares/cirurgia , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 26(10): 1937-43, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14516332

RESUMO

Monitoring of atrial rhythm in patients implanted with ICDs may improve accuracy in identifying supraventricular arrhythmias and, therefore, prevent inappropriate therapies. Since difficulties were found in dual chamber ICDs with separate leads, a new designed single lead dual chamber ICD system was tested. Twenty-five patients implanted with a Deikos A+ (single coil defibrillation lead with two atrial sensing rings combined with a dual chamber ICD with a high amplifying atrial channel) were tested. Atrial and ventricular signals were analyzed during sinus rhythm (SR) and sinus tachycardias (STs), atrial flutter and AF, and VT or VF. Follow-ups were performed after 1, 3, 6, 9, and 12 months after implantation. Analysis of EGM amplitudes of stored episodes revealed that atrial signals during atrial flutter (2.1 +/- 0.51 mV) were comparable to those of ST (2.2 +/- 0.5 mV). Atrial amplitudes during AF were significantly lower (0.81 +/- 0.5 mV, P<0.01). During VF atrial "sinus" signals (2 +/- 0.8 mV) were stable. Ventricular parameters did not differ from a standard ICD lead; defibrillation threshold was 11.4 +/- 4.5 J (16 patients). During intraoperative and prehospital discharge measurements, 97.1% of SR-P waves and 99.2% of atrial flutter waves were detected correctly. In AF 91.11% of atrial signals were detected. Analysis of 505 stored episodes showed that 96.8% of ST and 100% of atrial flutter and 100% of AF episodes have been classified correctly and no underdetection of VT/VF was found. The first experiences with the new VDD-ICD system show an increase of the specificity to detect ventricular tachycardias to a level comparable to dual chamber ICDs with two leads. The reliability of this system has to be proven in a prospective randomized study.


Assuntos
Desfibriladores Implantáveis , Cardiopatias/terapia , Eletrocardiografia , Eletrodos , Desenho de Equipamento , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
9.
Eur J Cardiothorac Surg ; 21(5): 853-7, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12062274

RESUMO

BACKGROUND: While morphologic integration of transplanted fetal cardiomyocytes into the ventricular myocardium is a well-known fact, no studies have yet shown transplanted cells to coherently contribute to contraction and electrical excitation of the host myocardium. The aim of this study was to prove the hypothesis that by transplanting cardiomyocytes with a higher intrinsic rhythmic rate into the myocardium of the left ventricle, these cells could act as an ectopic pacemaker by functional coupling with host cardiomyocytes. METHODS AND RESULTS: Dissociated fetal canine atrial cardiomyocytes including sinus nodal cells were delivered into the free wall of the left ventricle of adult canine X-linked muscular dystrophy dogs (n=2). These dogs fail to express Dystrophin in both cardiac and skeletal muscle. In the control group (n=2) fetal skin fibroblasts were used for grafting. A total of 3-4 weeks after transplantation the dogs underwent catheter ablation of the atrioventricular node (AV-node) and subsequent electrophysiological mapping studies. Transplanted cells were identified by Dystrophin immunoreactivity, indicating survival and morphological integration in the recipient heart. The expression of Connexin 43 between donor and recipient cells suggested formation of gap junctions between injected and host cardiomyocytes. After catheter ablation of the AV-node, a ventricular escape rhythm emerged driving the pace of the heart and originating from the labeled transplantation site. This effect could not be observed in the control group (n=2). CONCLUSIONS: The results constitute the first observation of phenomena indicating electrical and mechanical coupling between allogeneic donor cardiomyocytes and recipient myocardium in-vivo. Further experiments are necessary to evaluate the technique as a potential therapy for atrioventricular block.


Assuntos
Transplante de Tecido Fetal , Miocárdio/citologia , Função Ventricular Esquerda/fisiologia , Animais , Nó Atrioventricular/cirurgia , Transplante de Células , Cães , Distrofina/genética , Distrofina/imunologia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiologia , Contração Miocárdica , Função Ventricular Esquerda/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...