Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Interact Cardiovasc Thorac Surg ; 27(6): 850-855, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29917088

RESUMO

OBJECTIVES: To assess the feasibility and results of 'valve-in-valve' implantation using the 23-mm CoreValve for the treatment of degenerated 19-mm and 21-mm Mitroflow bioprostheses. METHODS: We retrospectively analysed all consecutive patients who underwent transcatheter aortic valve implantation for 19-mm and 21-mm Mitroflow bioprostheses. The height of implantation with respect to the ring of the Mitroflow prosthesis was targeted at -6 mm for the first 3 cases. In the following cases, the target was higher to promote free supra-annular movement of the leaflets. RESULTS: The procedure was successful in 17 of 18 patients (94%). For implantations above the limit of -6 mm, the mean gradient was 10.4 ± 2.6 mmHg compared with 28.1 ± 11.6 mmHg for implantations below the limit of -6 mm (P < 0.01). For patients with severe stenosis as main mechanism of failure of the bioprosthesis, the mean post-procedural gradient was 31.2 ± 11.8 mmHg compared with 12.7 ± 6 mmHg in the absence of severe stenosis (P < 0.01). Patient-prosthesis mismatch (indexed effective orifice area ≤ 0.85 cm2/m2) and severe mismatch (indexed effective orifice area ≤ 0.65 cm2/m2) were present in 83% (15 of 18) and 27% (5 of 18) of patients, respectively. We did not notice any complications following the procedures. Six months after the procedure, functional status was improved in all patients. CONCLUSIONS: Our short series demonstrates the ability to perform transcatheter 'valve-in-valve' implantation in 19-mm and 21-mm Mitroflow prostheses with satisfactory results, but high post-procedural gradients and patient-prosthesis mismatch remain a relatively frequent problem mostly when severe stenosis is the main mechanism of failure. Implantation in a high position is critical to decrease the rate of high postimplantation gradients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
2.
Ann Thorac Surg ; 94(3): 990-1, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22580172

RESUMO

A wrapping procedure for acute type A aortic dissection was performed on six elderly patients at high risk for conventional surgery. Aortic valve insufficiency was mild, with no malperfusion syndrome. A Teflon plaque or Dacron vascular prosthesis was passed around the aorta and tightened from the coronary ostia to the innominate artery. No severe neurologic complications or deaths occurred in the postoperative period. Computed tomography and magnetic resonance imaging imaging during follow-up showed aortic diameters had stabilized in all patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular , Doença Aguda , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Ponte Cardiopulmonar , Ecocardiografia Doppler/métodos , Feminino , Seguimentos , Idoso Fragilizado , Humanos , Tempo de Internação , Imageamento por Ressonância Magnética/métodos , Masculino , Polietilenotereftalatos , Medição de Risco , Estudos de Amostragem , Esternotomia/métodos , Taxa de Sobrevida , Técnicas de Sutura , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...