1.
J Infect Dis ; 204(9): 1413-22, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21933874

RESUMO

BACKGROUND: In 2006, a mumps outbreak occurred on a university campus despite ≥ 95% coverage of students with 2 doses of measles-mumps-rubella (MMR) vaccine. Using plasma samples from a blood drive held on campus before identification of mumps cases, we compared vaccine-induced preoutbreak mumps antibody levels between individuals who developed mumps (case patients) and those who did not develop mumps (nonpatients). METHODS: Preoutbreak samples were available from 11 case patients, 22 nonpatients who reported mumps exposure but no mumps symptoms, and 103 nonpatients who reported no known exposure and no symptoms. Antibody titers were measured by plaque reduction neutralization assay using Jeryl Lynn vaccine virus and the outbreak virus Iowa-G/USA-06 and by enzyme immunoassay (EIA). RESULTS: Preoutbreak Jeryl Lynn virus neutralization titers were significantly lower among case patients than unexposed nonpatients (P = .023), and EIA results were significantly lower among case patients than exposed nonpatients (P = .007) and unexposed nonpatients (P = .009). Proportionately more case patients than exposed nonpatients had a preoutbreak anti-Jeryl Lynn titer < 31 (64% vs 27%, respectively; P = .065), an anti-Iowa-G/USA-06 titer < 8 (55% vs 14%; P = .033), and EIA index standard ratio < 1.40 (64% vs 9%; P = .002) and < 1.71 (73% vs 14%, P = .001). DISCUSSION: Case patients generally had lower preoutbreak mumps antibody levels than nonpatients. However, titers overlapped and no cutoff points separated all mumps case patients from all nonpatients.


Assuntos
Anticorpos Antivirais/sangue , Surtos de Doenças , Caxumba/epidemiologia , Caxumba/prevenção & controle , Adolescente , Anticorpos Neutralizantes/sangue , Biomarcadores , Feminino , Humanos , Técnicas Imunoenzimáticas , Iowa/epidemiologia , Masculino , Vacina contra Sarampo-Caxumba-Rubéola/administração & dosagem , Vacina contra Sarampo-Caxumba-Rubéola/imunologia , Caxumba/imunologia , Estudantes , Ensaio de Placa Viral , Adulto Jovem
2.
Transfusion ; 51(4): 692-701, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20946198

RESUMO

BACKGROUND: Blood donor screening with enzyme immunoassays (EIAs) for antibodies to human T-lymphotropic virus (HTLV)-I, and later to HTLV-I/II, has led to the unnecessary deferral of tens of thousands of individuals. The licensure of the Abbott PRISM HTLV-I/HTLV-II chemiluminescent immunoassay (ChLIA) may permit the reinstatement of historically deferred donors. STUDY DESIGN AND METHODS: The efficacy of a reentry algorithm involving a follow-up sample from EIA-deferred donors testing HTLV-I/II ChLIA nonreactive was evaluated using 386 serologic confirmed-positive samples archived since the inception of anti-HTLV donor screening. Reactivity of the 386 samples by the ChLIA, when coupled with the package insert sensitivity data, may be used to demonstrate efficacy of the reentry algorithm. Donor incidence was also examined from 2008 through 2009 to evaluate changes to the existing HTLV screening policy. RESULTS: From January 1, 1995, to April 28, 2008, a total of 64,052 donors to the American Red Cross were deferred solely because of HTLV EIA false positivity, representing more than 130,000 US donors. HTLV ChLIA identified 386 confirmed-positive donations from 386 randomly selected donors representing reactivity to both the bioMérieux and the Abbott HTLV-I/II EIAs (95% confidence interval [CI], 99.2%-100%); both EIAs have since been discontinued. This is comparable to the detection of 843 of 843 confirmed-positive samples during the ChLIA clinical trials (95% CI, 99.48%-100%). Incident HTLV infections occurred primarily among female repeat donors during 2008 throughout 2009. CONCLUSIONS: Donors testing falsely positive by historic EIAs since 1988 should be considered for reinstatement if a contemporary sample tests ChLIA nonreactive. Changes to the existing screening algorithm seem unlikely since new HTLV infections were detected among repeat donors.


Assuntos
Anticorpos Antivirais/imunologia , Doadores de Sangue , Seleção do Doador/métodos , Reações Falso-Positivas , Vírus Linfotrópico T Tipo 1 Humano/isolamento & purificação , Vírus Linfotrópico T Tipo 2 Humano/isolamento & purificação , Algoritmos , Feminino , Vírus Linfotrópico T Tipo 1 Humano/imunologia , Vírus Linfotrópico T Tipo 2 Humano/imunologia , Humanos , Técnicas Imunoenzimáticas , Masculino
3.
Transfusion ; 48(11): 2315-22, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18647367

RESUMO

BACKGROUND: Blood donor testing for antibody to hepatitis B core antigen (anti-HBc) has been used in the United States for more than 20 years as a surrogate to prevent transmission by transfusion of non-A, non-B hepatitis, as a human immunodeficiency virus surrogate, and to reduce transmission of hepatitis B virus (HBV). Nonspecific anti-HBc assays have caused deferral of hundreds of thousands of otherwise qualified donors. A more specific anti-HBc test and a sensitive HBV DNA test should permit donor reentry after false-positive anti-HBc. STUDY DESIGN AND METHODS: A total of 1324 otherwise eligible volunteer donors, deferred for anti-HBc reactivity on more than one occasion, were recruited from four collection facilities. They were tested using a licensed, more specific anti-HBc test, a licensed hepatitis B surface antigen (HBsAg) test, and a licensed HBV DNA assay with a 95 percent limit of detection of not more than 10 copies per mL. RESULTS: From 11 to 32 percent of donors contacted by participating sites entered the study. Overall, 488 (37%) of the donors were negative on the more specific anti-HBc test. The proportion of putative false-positive samples varied according to the test responsible for the original deferral. A single donor, negative for the presence of anti-HBc and HBsAg, was positive for the presence of HBV DNA in one of three replicates. Repeat testing of this donor 10 months later was negative for the presence of all markers of HBV infection, and the donor had a history of HBV vaccination with documented postimmunization anti-HBs seroconversion 10 years before her anti-HBc deferral, and was considered HBV DNA false positive. CONCLUSION: These data support reentry of donors with false-positive anti-HBc results on the relatively nonspecific assays that have been in use in the United States for more than 20 years.


Assuntos
Algoritmos , Bancos de Sangue/normas , Doadores de Sangue , DNA Viral/sangue , Anticorpos Anti-Hepatite B/sangue , Antígenos do Núcleo do Vírus da Hepatite B/imunologia , Hepatite B/prevenção & controle , Programas de Rastreamento/normas , Adulto , Erros de Diagnóstico , Reações Falso-Positivas , Feminino , Hepatite B/sangue , Hepatite B/diagnóstico , Hepatite B/imunologia , Humanos , Masculino , Guias de Prática Clínica como Assunto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos , United States Food and Drug Administration , Voluntários
4.
Clin Transplant ; 18 Suppl 12: 12-5, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15217401

RESUMO

PURPOSE: Several recent publications have increased awareness that transplanted organs can transmit infectious diseases. In light of the recent report describing the transmission of Trypanosoma cruzi infection by an organ donor in the United States (MMWR 2002: 51: 210), we have tested archived serum samples from our Organ Procurement Organization's (OPO's) deceased organ donors and live donors from 23 October 1995 through 1 March 2002. METHODS: A total of 1117 serum samples from 558 locally recovered deceased donors, 178 imported deceased donors, and 212 live donors were tested (several duplicates were included). Samples were screened for antibodies to T. cruzi, the protozoan parasite that causes Chagas' disease, with a passive particle agglutination assay (Fujirebio, Inc., Tokyo, Japan). Indeterminate samples (those agglutinating both sensitized and control particles) were absorbed with control antigen and re-tested. Inconclusive samples (those not yielding clearly negative or positive results) were re-tested using the original test format, and if persistently inconclusive, were assayed by radio-immune precipitation (RIPA). RESULTS: Of the 770 local OPO donors (deceased and live donor) and the 178 imported donors tested, 52 (5.5%) were indeterminate, but following absorption, all were negative. Forty-four samples (4.6%) were inconclusive and after re-testing 34 were negative while 10 remained inconclusive. Those 10 samples were found to be negative by RIPA. CONCLUSIONS: The risk of transmission of Chagas' disease by organ transplantation in the Midwestern United States is low because during a 6.5 year period, none of our deceased or live donors tested positive for antibodies to T. cruzi. Although the passive particle agglutination test is simple to perform, easy to interpret and rapid enough to be used in screening organ donors, because of the rate of false positive results, it should only be utilized when the donor population is at high risk for previous exposure to T. cruzi.


Assuntos
Anticorpos Antiprotozoários/isolamento & purificação , Doença de Chagas/transmissão , Doadores de Tecidos , Trypanosoma cruzi/imunologia , Testes de Aglutinação , Animais , Humanos , Meio-Oeste dos Estados Unidos , Ensaio de Radioimunoprecipitação
5.
Transfusion ; 43(3): 309-13, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12675714

RESUMO

BACKGROUND: Both CMV-seronegative blood and unscreened, filtered blood carry a low but definite risk of transmitting CMV infection. To explain this residual risk, evidence of cell-free viremia was sought in seroconverting and seroprevalent blood donors and seroconverting transfusion recipients by means of a plasma-based assay for CMV DNA. STUDY DESIGN AND METHODS: A CMV DNA PCR assay (COBAS Amplicor CMV Monitor, Roche) was used to detect CMV DNA in 384 paired plasma samples from 192 donors who seroconverted to anti-CMV, 488 anti-CMV EIA-positive samples from 60 seroprevalent donors, and 113 serial samples from 11 seroconverting recipients with posttransfusion CMV hepatitis. RESULTS: Three of 384 samples from 192 seroconverting donors had low levels of plasma CMV DNA (400-1600 copies/mL); one donor was positive before seroconversion, and the other two, after seroconversion. None of the 488 serial samples from 60 anti-CMV- positive donors contained CMV DNA in plasma. Three of 11 recipients demonstrated transient plasma viremia that temporally coincided with seroconversion. CONCLUSIONS: Plasma CMV DNA was detected in a small percentage of seroconverting blood donors and a larger percentage of recipients but was undetectable in seroprevalent donors. Plasma viremia in seroconverting donors may partially explain the low residual risk of CMV transmission by both CMV-seronegative and WBC-reduced seropositive blood.


Assuntos
Anticorpos Antivirais/sangue , Doadores de Sangue , Transfusão de Sangue , Citomegalovirus/imunologia , Viremia , Citomegalovirus/genética , Infecções por Citomegalovirus/prevenção & controle , Infecções por Citomegalovirus/transmissão , DNA Viral/sangue , Humanos , Reação em Cadeia da Polimerase , Reação Transfusional
6.
Transfusion ; 42(11): 1507-13, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12421226

RESUMO

BACKGROUND: Two HCV antibody tests (EIA 2.0 [EIA2], Abbott; and the Version 3.0 ELISA [EIA3], Ortho) are currently licensed for screening of US blood donors. Testing of donors for HCV RNA allows comparison of the sensitivities of the two antibody-screening assays. STUDY DESIGN AND METHODS: All allogeneic blood donations at 13 US test sites were screened for HCV RNA by testing plasma minipools using an investigational assay (COBAS AmpliScreen HCV test, v2.0, Roche Molecular Systems). Some sites screened for HCV antibody by EIA2 and some used EIA3. The frequency of RNA-positive and antibody-negative (RNA-pos and Ab-neg) donations among donors screened by each antibody assay was compared. Antibody appearance was assessed in a donor follow-up study. RESULTS: A total of 5.51 x 10(6) donations were screened for HCV RNA. Of these, 2.27 million were screened for antibody by EIA2, and 3.24 million by EIA3. Twenty-three donations were HCV RNA-pos and Ab-neg. The frequency of RNA-pos and Ab-neg donations was higher among donations screened by EIA2 (1 in 134,000), compared to those screened by EIA3 (1 in 540,000) (p = 0.001). Of the 17 RNA-pos and Ab-neg donations identified by test sites that used EIA2, 14 were retested by EIA3 and 10 (71%) were reactive. Most RNA-pos and Ab-neg donors appear to be in the process of seroconversion. Donors that were initially EIA2-negative and EIA3-reactive showed a more prolonged pattern of seroconversion compared to those that were initially nonreactive by both antibody assays. Four donors were EIA2-negative, EIA3-reactive, and RIBA-indeterminate (c33c) for at least 90 days, 1 for more than 317 days. CONCLUSION: EIA3 would have detected the majority of RNA-positive donations missed by EIA2. Some RNA-positive donors are EIA2-negative and EIA3-reactive for a prolonged period of time.


Assuntos
Doadores de Sangue , Ensaio de Imunoadsorção Enzimática , Hepacivirus/isolamento & purificação , Anticorpos Anti-Hepatite C/sangue , Hepatite C/sangue , Técnicas Imunoenzimáticas , Programas de Rastreamento/métodos , RNA Viral/sangue , Viremia/sangue , Adulto , Alanina Transaminase/sangue , Biomarcadores , Feminino , Seguimentos , Genótipo , Hepacivirus/genética , Hepacivirus/imunologia , Hepatite C/diagnóstico , Hepatite C/epidemiologia , Hepatite C/virologia , Humanos , Immunoblotting , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estudos Soroepidemiológicos , Fatores de Tempo , Estados Unidos/epidemiologia , Viremia/diagnóstico , Viremia/epidemiologia , Viremia/virologia
SELEÇÃO DE REFERÊNCIAS