Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros










Intervalo de ano de publicação
2.
J Diabetes Sci Technol ; 17(4): 1029-1037, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35043720

RESUMO

BACKGROUND: Clinical decision support systems that incorporate information from frequent insulin measurements to enhance individualized diabetes management remain an unmet goal. The development of a disposable insulin strip for fast decentralized point-of-care detection replacing the current centralized lab-based methods used in clinical practice would be highly desirable to improve the establishment of individual insulin absorption patterns and algorithm modeling processes. METHODS: We carried out the development and optimization of a novel decentralized disposable insulin electrochemical sensor focusing on obtaining high analytical and operational performance toward achieving a true point-of-care insulin testing device for clinical on-site application. RESULTS: Our novel insulin immunosensor demonstrated an attractive performance and efficient user-friendly operation by providing high sensitivity capability to detect endogenous and analog insulin with a limit of detection of 30.2 pM (4.3 µiU/mL), rapid time-to-result, stability toward remote site application, and scalable low-cost fabrication with an estimated cost-of-goods for disposable consumables of below $5, capable of near real-time insulin detection in a microliter (≤10 µL) sample droplet of undiluted serum within 30 minutes. CONCLUSIONS: The results obtained in the optimization and characterization of our novel insulin sensor illustrate its suitability for its potential application in remote clinical environments for frequent insulin monitoring. Future work will test the insulin sensor in a clinical research setting to assess its efficacy in individuals with type 1 diabetes.


Assuntos
Técnicas Biossensoriais , Insulina , Humanos , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Insulina Regular Humana , Tomada de Decisão Clínica
3.
J Diabetes Sci Technol ; 17(4): 1038-1048, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35118893

RESUMO

BACKGROUND: The estimation of available active insulin remains a limitation of automated insulin delivery systems. Currently, insulin pumps calculate active insulin using mathematical decay curves, while quantitative measurements of insulin would explicitly provide person-specific PK insulin dynamics to assess remaining active insulin more accurately, permitting more effective glucose control. METHODS: We performed the first clinical evaluation of an insulin immunosensor chip, providing near real-time measurements of insulin levels. In this study, we sought to determine the accuracy of the novel insulin sensor and assess its therapeutic risk and benefit by presenting a new tool developed to indicate the potential therapeutic consequences arising from inaccurate insulin measurements. RESULTS: Nine adult participants with type-1 diabetes completed the study. The change from baseline in immunosensor-measured insulin levels was compared with values obtained by standard enzyme-linked immunosorbant assay (ELISA) after preprandial injection of insulin. The point-of-care quantification of insulin levels revealed similar temporal trends as those from the laboratory insulin ELISA. The results showed that 70% of the paired immunosensor-reference values were concordant, which suggests that the patient could take action safely based on insulin concentration obtained by the novel sensor. CONCLUSIONS: This proposed technology and preliminary feasibility evaluation show encouraging results for near real-time evaluation of insulin levels, with the potential to improve diabetes management. Real-time measurements of insulin provide person-specific insulin dynamics that could be used to make more informed decisions regarding insulin dosing, thus helping to prevent hypoglycemia and improve diabetes outcomes.


Assuntos
Técnicas Biossensoriais , Diabetes Mellitus Tipo 1 , Adulto , Humanos , Insulina , Glicemia/análise , Automonitorização da Glicemia/métodos , Imunoensaio , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina Regular Humana/uso terapêutico
4.
Nat Rev Neurol ; 18(8): 497-507, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35681103

RESUMO

Although levodopa remains the most efficacious symptomatic therapy for Parkinson disease (PD), management of levodopa treatment during the advanced stages of the disease is extremely challenging. This difficulty is a result of levodopa's short half-life, a progressive narrowing of the therapeutic window, and major inter-patient and intra-patient variations in the dose-response relationship. Therefore, a suitable alternative to repeated oral administration of levodopa is being sought. Recent research efforts have focused on the development of novel levodopa delivery strategies and wearable physical sensors that track symptoms and disease progression. However, the need for methods to monitor the levels of levodopa present in the body in real time has been overlooked. Advances in chemical sensor technology mean that the development of wearable and mobile biosensors for continuous or frequent levodopa measurements is now possible. Such levodopa monitoring could help to deliver personalized and timely medication dosing to alleviate treatment-related fluctuations in the symptoms of PD. Therefore, with the aim of optimizing therapeutic management of PD and improving the quality of life of patients, we share our vision of a future closed-loop autonomous wearable 'sense-and-act' system. This system consists of a network of physical and chemical sensors coupled with a levodopa delivery device and is guided by effective big data fusion algorithms and machine learning methods.


Assuntos
Levodopa , Doença de Parkinson , Antiparkinsonianos/uso terapêutico , Progressão da Doença , Humanos , Levodopa/uso terapêutico , Doença de Parkinson/diagnóstico , Doença de Parkinson/tratamento farmacológico , Qualidade de Vida
5.
Anal Chem ; 94(23): 8335-8345, 2022 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-35653647

RESUMO

The ability to continuously monitor the concentration of specific molecules in the body is a long-sought goal of biomedical research. For this purpose, interstitial fluid (ISF) was proposed as the ideal target biofluid because its composition can rapidly equilibrate with that of systemic blood, allowing the assessment of molecular concentrations that reflect full-body physiology. In the past, continuous monitoring in ISF was enabled by microneedle sensor arrays. Yet, benchmark microneedle sensors can only detect molecules that undergo redox reactions, which limits the ability to sense metabolites, biomarkers, and therapeutics that are not redox-active. To overcome this barrier, here, we expand the scope of these devices by demonstrating the first use of microneedle-supported electrochemical, aptamer-based (E-AB) sensors. This platform achieves molecular recognition based on affinity interactions, vastly expanding the scope of molecules that can be sensed. We report the fabrication of microneedle E-AB sensor arrays and a method to regenerate them for multiple uses. In addition, we demonstrate continuous molecular measurements using these sensors in flow systems in vitro using single and multiplexed microneedle array configurations. Translation of the platform to in vivo measurements is possible as we demonstrate with a first E-AB measurement in the ISF of a rodent. The encouraging results reported in this work should serve as the basis for future translation of microneedle E-AB sensor arrays to biomedical research in preclinical animal models.


Assuntos
Monitoramento de Medicamentos , Agulhas , Animais , Biomarcadores/análise , Monitoramento de Medicamentos/métodos , Líquido Extracelular/química , Oligonucleotídeos/análise
6.
Nat Biomed Eng ; 6(11): 1214-1224, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35534575

RESUMO

Implementations of wearable microneedle-based arrays of sensors for the monitoring of multiple biomarkers in interstitial fluid have lacked system integration and evidence of robust analytical performance. Here we report the development and testing of a fully integrated wearable array of microneedles for the wireless and continuous real-time sensing of two metabolites (lactate and glucose, or alcohol and glucose) in the interstitial fluid of volunteers performing common daily activities. The device works with a custom smartphone app for data capture and visualization, comprises reusable electronics and a disposable microneedle array, and is optimized for system integration, cost-effective fabrication via advanced micromachining, easier assembly, biocompatibility, pain-free skin penetration and enhanced sensitivity. Single-analyte and dual-analyte measurements correlated well with the corresponding gold-standard measurements in blood or breath. Further validation of the technology in large populations with concurrent validation of sensor readouts through centralized laboratory tests should determine the robustness and utility of real-time simultaneous monitoring of several biomarkers in interstitial fluid.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Humanos , Líquido Extracelular , Glucose , Biomarcadores
7.
J Am Chem Soc ; 143(31): 12194-12201, 2021 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-34291944

RESUMO

The coronavirus SARS-CoV-2 can survive in wastewater for several days with a potential risk of waterborne human transmission, hence posing challenges in containing the virus and reducing its spread. Herein, we report on an active biohybrid microrobot system that offers highly efficient capture and removal of target virus from various aquatic media. The algae-based microrobot is fabricated by using click chemistry to functionalize microalgae with angiotensin-converting enzyme 2 (ACE2) receptor against the SARS-CoV-2 spike protein. The resulting ACE2-algae-robot displays fast (>100 µm/s) and long-lasting (>24 h) self-propulsion in diverse aquatic media including drinking water and river water, obviating the need for external fuels. Such movement of the ACE2-algae-robot offers effective "on-the-fly" removal of SARS-CoV-2 spike proteins and SARS-CoV-2 pseudovirus. Specifically, the active biohybrid microrobot results in 95% removal of viral spike protein and 89% removal of pseudovirus, significantly exceeding the control groups such as static ACE2-algae and bare algae. These results suggest considerable promise of biologically functionalized algae toward the removal of viruses and other environmental threats from wastewater.


Assuntos
Enzima de Conversão de Angiotensina 2/química , Biotecnologia/métodos , Microalgas/química , SARS-CoV-2/isolamento & purificação , Águas Residuárias/virologia , Purificação da Água/métodos , Enzima de Conversão de Angiotensina 2/metabolismo , Biotecnologia/instrumentação , Linhagem Celular , Química Click , Humanos , Receptores Virais/química , Receptores Virais/metabolismo , SARS-CoV-2/metabolismo , Purificação da Água/instrumentação
8.
Bioeng Transl Med ; 6(2): e10201, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34027090

RESUMO

As wearable healthcare monitoring systems advance, there is immense potential for biological sensing to enhance the management of type 1 diabetes (T1D). The aim of this work is to describe the ongoing development of biomarker analytes in the context of T1D. Technological advances in transdermal biosensing offer remarkable opportunities to move from research laboratories to clinical point-of-care applications. In this review, a range of analytes, including glucose, insulin, glucagon, cortisol, lactate, epinephrine, and alcohol, as well as ketones such as beta-hydroxybutyrate, will be evaluated to determine the current status and research direction of those analytes specifically relevant to T1D management, using both in-vitro and on-body detection. Understanding state-of-the-art developments in biosensing technologies will aid in bridging the gap from bench-to-clinic T1D analyte measurement advancement.

9.
Nat Commun ; 12(1): 1542, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33750816

RESUMO

Despite the fast development of various energy harvesting and storage devices, their judicious integration into efficient, autonomous, and sustainable wearable systems has not been widely explored. Here, we introduce the concept and design principles of e-textile microgrids by demonstrating a multi-module bioenergy microgrid system. Unlike earlier hybrid wearable systems, the presented e-textile microgrid relies solely on human activity to work synergistically, harvesting biochemical and biomechanical energy using sweat-based biofuel cells and triboelectric generators, and regulating the harvested energy via supercapacitors for high-power output. Through energy budgeting, the e-textile system can efficiently power liquid crystal displays continuously or a sweat sensor-electrochromic display system in pulsed sessions, with half the booting time and triple the runtime in a 10-min exercise session. Implementing "compatible form factors, commensurate performance, and complementary functionality" design principles, the flexible, textile-based bioenergy microgrid offers attractive prospects for the design and operation of efficient, sustainable, and autonomous wearable systems.


Assuntos
Bioengenharia/instrumentação , Engenharia Biomédica/instrumentação , Têxteis , Dispositivos Eletrônicos Vestíveis , Fontes de Energia Bioelétrica , Fenômenos Biomecânicos , Técnicas Biossensoriais/instrumentação , Humanos , Suor
10.
Adv Healthc Mater ; 10(17): e2002255, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33646612

RESUMO

While the current smartwatches and cellphones can readily track mobility and vital signs, a new generation of wearable devices is rapidly developing to enable users to monitor their health parameters at the molecular level. Within this emerging class of wearables, microneedle-based transdermal sensors are in a prime position to play a key role in synergizing the significant advantages of dermal interstitial fluid (ISF) as a rich source of clinical indicators and painless skin pricking to allow the collection of real-time diagnostic information. While initial efforts of microneedle sensing focused on ISF extraction coupled with either on-chip analysis or off-chip instrumentation, the latest trend has been oriented toward assembling electrochemical biosensors on the tip of microneedles to allow direct continuous chemical measurements. In this context, significant advances have recently been made in exploiting microneedle-based devices for real-time monitoring of various metabolites, electrolytes, and therapeutics and toward the simultaneous multiplexed detection of key chemical markers; yet, there are several grand challenges that still exist. In this review, we outline current progress, recent trends, and new capabilities of microneedle-empowered sensors, along with the current unmet challenges and a future roadmap toward transforming the latest innovations in the field to commercial products.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Administração Cutânea , Agulhas , Pele
11.
Biosens Bioelectron ; 167: 112512, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32877776

RESUMO

Here we describe the development of a dual electrochemical immunosensor microchip for simultaneous detection of insulin (I) and cortisol (C) biomarkers that can enhance the ability to improve glucose regulation using automated insulin delivery. The successful realization of the simultaneous I and C measurements has been realized by integrating different enzymatically-tagged competitive and sandwich immunoassay formats on a single chip platform. The insulin detection is based on a peroxidase (HRP)-labeled sandwich assay whereas the cortisol detection relies on an alkaline phosphatase (ALP)-labeled competitive immunoassay. The attractive analytical performance of the dual marker immunosensor, with no apparent cross-talk, was achieved through systematic optimization of the incubation and amperometric detection of the different captured enzyme tags. Evaluation of dual biosensor chip in untreated serum samples indicated favorable simultaneous detection of picomolar (pM) insulin and nanomolar (nM) cortisol concentrations in a single microliter sample droplet within less than 25min. The new dual immunosensor chip offers considerable promise for frequent decentralized testing of I and C towards a tighter glycemic control and improved management of diabetes.


Assuntos
Técnicas Biossensoriais , Eletrodos , Hidrocortisona , Imunoensaio , Insulina
12.
J Am Chem Soc ; 142(13): 5991-5995, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32202103

RESUMO

There are urgent needs for sensing devices capable of distinguishing between episodes of opioid overdose and nerve agent poisoning. This work presents a wearable microneedle sensor array for minimally invasive continuous electrochemical detection of opioid (OPi) and organophosphate (OP) nerve agents on a single patch platform. The new multimodal microneedle sensor array relies on unmodified and organophosphorus hydrolase (OPH) enzyme-modified carbon paste (CP) microneedle electrodes for square wave voltammetric (SWV) detection of the fentanyl and nerve agent targets, respectively. Such real-time simultaneous sensing provides distinct unique information, along with attractive analytical performance, including high sensitivity, selectivity, and stability, for real-time on-body OPi-OP analysis. The patch represents the first sensing device capable of continuously monitoring fentanyl down to the nanomolar level through a nanomaterial-based multilayered surface architecture. Applicability of the sensor array toward opioids screening is demonstrated for morphine and norfentanyl. Successful OPi-OP detection conducted in a skin-mimicking phantom gel demonstrates the suitability of the device for rapid on-body sensing. Such progress toward continuous minimally invasive transdermal analysis of drugs of abuse and nerve agents holds promise for rapid countermeasures for protecting soldiers, civilians, and healthcare personnel.


Assuntos
Analgésicos Opioides/análise , Técnicas Biossensoriais/instrumentação , Fentanila/análise , Agentes Neurotóxicos/análise , Organofosfatos/análise , Desenho de Equipamento , Humanos , Agulhas , Dispositivos Eletrônicos Vestíveis
13.
Iran J Microbiol ; 12(5): 404-410, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33603994

RESUMO

BACKGROUND AND OBJECTIVES: The aim of this study was to determine the prevalence of Salmonella at broiler breeder farms of Iran and investigate the factors underlying salmonellosis in these farms. This is a cross-sectional investigation conducted in 23 provinces of Iran. MATERIALS AND METHODS: Fecal samples were collected from 139 broiler breeder farms in the country and standard bacteriological tests were carried out on the samples for the isolation of Salmonella. The serological tests were then applied for the samples that were positive in the bacteriological test. The information on the sampled farms extracted from the Iran GIS-VET Monitoring and Surveillance System was used for the analysis of the risk factors. RESULTS: A total of 11 farms out of the 139 sampled farms were infected with Salmonella with the largest number of infected cases related to Tehran and Fars Provinces. CONCLUSION: The statistical analysis results showed that flocks with older ages and farms with larger number of houses are at greater risk of Salmonella infection.

14.
Anal Chem ; 92(2): 2291-2300, 2020 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-31874029

RESUMO

Diabetic ketoacidosis (DKA), a severe complication of diabetes mellitus with potentially fatal consequences, is characterized by hyperglycemia and metabolic acidosis due to the accumulation of ketone bodies, which requires people with diabetes to monitor both glucose and ketone bodies. However, despite major advances in diabetes management mainly since the emergence of new-generation continuous glucose monitoring (CGM) devices capable of in vivo monitoring of glucose directly in the interstitial fluid (ISF), the continuous monitoring of ketone bodies is yet to be addressed. Here, we present the first use of a real-time continuous ketone bodies monitoring (CKM) microneedle platform. The system is based on the electrochemical monitoring of ß-hydroxybutyrate (HB) as the dominant biomarker of ketone formation. Such real-time HB detection has been realized using the ß-hydroxybutyrate dehydrogenase (HBD) enzymatic reaction and by addressing the major challenges associated with the stable confinement of the enzyme/cofactor couple (HBD/NAD+) and with a stable and selective low-potential fouling-free anodic detection of NADH. The resulting CKM microneedle device displays an attractive analytical performance, with high sensitivity (with low detection limit, 50 µM), high selectivity in the presence of potential interferences, along with good stability during prolonged operation in artificial ISF. The potential applicability of this microneedle sensor toward minimally invasive monitoring of ketone bodies has been demonstrated in a phantom gel skin-mimicking model. The ability to detect HB along with glucose and lactate on a single microneedle array has been demonstrated. These findings pave the way for CKM and for the simultaneous microneedle-based monitoring of multiple diabetes-related biomarkers toward a tight glycemic control.


Assuntos
Cetoacidose Diabética/diagnóstico , Líquido Extracelular/química , Glucose/análise , Corpos Cetônicos/análise , Cetose/diagnóstico , Ácido Láctico/análise , Técnicas Biossensoriais , Automonitorização da Glicemia , Técnicas Eletroquímicas , Humanos , Agulhas , Fatores de Tempo
15.
Angew Chem Int Ed Engl ; 59(9): 3480-3485, 2020 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-31863710

RESUMO

A multifunctional motile microtrap is developed that is capable of autonomously attracting, trapping, and destroying pathogens by controlled chemoattractant and therapeutic agent release. The onion-inspired multi-layer structure contains a magnesium engine core and inner chemoattractant and therapeutic layers. Upon chemical propulsion, the magnesium core is depleted, resulting in a hollow structure that exposes the inner layers and serves as structural trap. The sequential dissolution and autonomous release of the chemoattractant and killing agents result in long-range chemotactic attraction, trapping, and destruction of motile pathogens. The dissolved chemoattractant (l-serine) significantly increases the accumulation and capture of motile pathogens (E. coli) within the microtrap structure, while the internal release of silver ions (Ag+ ) leads to lysis of the pathogen accumulated within the microtrap cavity.


Assuntos
Fatores Quimiotáticos/química , Serina/química , Fatores Quimiotáticos/farmacologia , Portadores de Fármacos/química , Escherichia coli/efeitos dos fármacos , Escherichia coli/fisiologia , Fluoresceína-5-Isotiocianato/química , Íons/química , Magnésio/química , Imagem Óptica , Polímeros/química , Rodaminas/química , Prata/química , Xilenos/química
16.
ACS Nano ; 13(11): 13325-13332, 2019 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-31661258

RESUMO

Alzheimer's disease is a devastating condition characterized by a progressive and slow brain decay in elders. Here, we developed a paper-based lateral flow immunoassay for simultaneous and fast determination of Alzheimer's blood biomarkers, fetuin B and clusterin. Selective antibodies to targeted biomarkers were immobilized on gold nanoparticles (AuNPs) and deposited on paper pads. After adding the sample on the paper-based device, the biofluid laterally flows toward the selective antibody, permitting AuNP-Ab accumulation on the test zone, which causes a color change from white to pink. Image analysis was performed using a customized algorithm for the automatic recognition of the area of analysis and color clustering. Colorimetric detection was compared to electrochemical methods for the precise quantification of biomarkers. The best performance was found for the color parameter "L*". Good linearity (R2 = 0.988 and 0.998) and reproducibility (%RSD = 2.79% and 1.82%, N = 3) were demonstrated for the quantification of fetuin B and clusterin, respectively. Furthermore, the specificity of the immunosensor was tested on mixtures of proteins, showing negligible cross-reactivity and good performance in complex environments. We believe that our biosensor has a potential for early-stage diagnosis of Alzheimer's disease and toward a better understanding of Alzheimer's developing mechanisms.


Assuntos
Doença de Alzheimer/diagnóstico , Clusterina/análise , Colorimetria , Fetuína-B/análise , Imunoensaio , Papel , Técnicas Biossensoriais , Ouro/química , Humanos , Nanopartículas Metálicas/química
17.
Angew Chem Int Ed Engl ; 58(19): 6376-6379, 2019 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-30868724

RESUMO

Performing bioassay formats based on enzyme and antibody recognition reactions with a single detection chip remains an unmet challenge owing to the different requirements of such bioassays. Herein, we describe a dual-marker biosensor chip, integrating enzyme and antibody-based assays for simultaneous electrochemical measurements of insulin (I) and glucose (G). Simultaneous G/I sensing has been realized by addressing key fabrication and operational challenges associated with the different assay requirements and surface chemistry. The I immunosensor relies on a peroxidase-labeled sandwich immunoassay, while G is monitored through reaction with glucose oxidase. The dual diabetes biomarker chip offers selective and reproducible detection of picomolar I and millimolar G concentrations in a single microliter sample droplet within less than 30 min, including direct measurements in whole blood and saliva samples. The resulting integrated enzymatic-immunoassay biosensor chip opens a new realm in point-of-care multiplexed biomarker detection.


Assuntos
Biomarcadores/análise , Glucose/análise , Imunoensaio/métodos , Insulina/análise , Biomarcadores/sangue , Técnicas Eletroquímicas/métodos , Eletrodos , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Glucose Oxidase/química , Glucose Oxidase/metabolismo , Humanos , Insulina/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Saliva/metabolismo
18.
Trop Anim Health Prod ; 51(3): 689-695, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30377950

RESUMO

In this study, the prevalence and spatial distribution of Newcastle disease, infectious bronchitis, and avian influenza have been evaluated in commercial broiler farms in 31 provinces in Iran. In this survey, a total of 233 affected broiler chicken farms were sampled. The infectious bronchitis virus (alone) was detected with highest frequency in 60 farms, and separately or combined with other agents, in 110 farms; Newcastle disease virus, separately, was detected in 28 farms, and in 63 farms separately or combined with other infectious agents; and avian influenza H9N2 was detected in 22 farms separately and in 51 farms separately or concomitant with other infectious agents. The sample tested negative for all H5 serotypes. The results of the present study show that the most prevalent avian viral infectious disease contributing to respiratory syndromes in broiler farms in Iran was infectious bronchitis due to infectious bronchitis virus serotypes variant 2 and 793/B. On the other hand, combined with the alternation of dominant viruses and circulating strains, flocks are exposed to unremitting anamorphic viral infections. Thus, the permanent monitoring of cases that have occurred and the review of vaccination plans of affected flocks every year are some of the necessary measures needed for strategic control of respiratory syndrome in broilers. It is noteworthy that execution of epidemiologic examinations on the cogent factors of prevalence of this syndrome and defeat of vaccination strategy in the flocks is urgent and has to be fulfilled on the definite causes of time.


Assuntos
Galinhas , Infecções por Coronavirus/veterinária , Influenza Aviária/epidemiologia , Doença de Newcastle/epidemiologia , Doenças das Aves Domésticas/virologia , Animais , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/virologia , Fazendas , Vírus da Bronquite Infecciosa , Vírus da Influenza A Subtipo H9N2 , Irã (Geográfico)/epidemiologia , Doenças das Aves Domésticas/epidemiologia , Prevalência
19.
Foods ; 7(9)2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30200448

RESUMO

Rapid and precise analytical tools are essential for monitoring food safety and screening of any undesirable contaminants, allergens, or pathogens, which may cause significant health risks upon consumption. Substantial developments in analytical techniques have empowered the analyses and quantitation of these contaminants. However, conventional techniques are limited by delayed analysis times, expensive and laborious sample preparation, and the necessity for highly-trained workers. Therefore, prompt advances in electrochemical biosensors have supported significant gains in quantitative detection and screening of food contaminants and showed incredible potential as a means of defying such limitations. Apart from indicating high specificity towards the target analytes, these biosensors have also addressed the challenge of food industry by providing high analytical accuracy within complex food matrices. Here, we discuss some of the recent advances in this area and analyze the role and contributions made by electrochemical biosensors in the food industry. This article also reviews the key challenges we believe biosensors need to overcome to become the industry standard.

20.
Iran J Microbiol ; 10(1): 65-71, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29922421

RESUMO

BACKGROUND AND OBJECTIVES: Different epidemiological studies have found that backyard chickens are a reservoir for poultry diseases. Most backyard chicken flocks have a poor level of biosecurity, which increases the risk of spread of diseases. In recent years, the number of backyard chickens has been on the rise in Iran. However, the health status of backyard flocks is still poorly documented. Thus, this study aimed at examining the seroprevalence of antibodies against infectious bronchitis virus (IBV) and molecular surveillance and genotyping of IBV among backyard chickens (without vaccination history) in Mazandaran province, North of Iran, 2014. MATERIALS AND METHODS: A total of 460 blood samples of unvaccinated backyard chickens in the mentioned area were tested for antibodies against IBV using commercial ELISA. Also, cecal tonsils were collected from 75 chickens in the same area. Real time RT-PCR (for detection) and RT-PCR and sequencing spike gene were performed. RESULTS: The seropositivity rate was 54.5%. In addition, we detected 793/B, Variant 2, and QX in the backyard flocks and performed phylogenetic studies on them. The phylogenetic study revealed that the detected genotypes had high homology with IBV strains that were infected broilers, pullets, and layers in Iran. CONCLUSION: There is a need for continuous monitoring of IBV among avian species to complete the epidemiological map and work on the pathogenesis of Iranian IBV strains in Iranian backyard chickens.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...