Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Zentralbl Chir ; 148(5): 438-444, 2023 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-37846166

RESUMO

Endovascular revascularisation with paclitaxel-coated balloons for the treatment of peripheral artery disease has been shown to be an effective therapeutic option in the femoropopliteal segment. The antiproliferative effect of paclitaxel prevents restenosis. In contrast, in the infra-popliteal segment, the evidence is currently conflicting. However, there is evidence of an increased risk of amputation and mortality from the second year after angioplasty with paclitaxel-coated balloons. This may be due to a dose-dependent cytotoxic effect of paclitaxel. Sirolimus-coated balloons might therefore be an alternative because sirolimus is cytostatic rather than cytotoxic and thus has a wide therapeutic window.Three single-arm pilot studies (50, 25, and 50 patients, respectively) show that angioplasty with sirolimus-coated balloons leads to comparable results to those reported from paclitaxel-coated balloons (late lumen loss at 6 months: 0.29 mm; primary patency at 12 months: femoropopliteal 79%-82%, infra-popliteal 59%; freedom from target lesion revascularization at 12 months: femoropopliteal 83%-94%, infra-popliteal 86%). Randomised controlled trials comparing standard balloon angioplasty and paclitaxel-coated balloons for the treatment of intermittent claudication or chronic limb-threatening ischaemia are active and are expected to provide efficacy and safety results from mid 2024.This review presents the results of pilot studies on angioplasty with sirolimus-coated balloons for the treatment of peripheral artery disease and reviews currently ongoing randomised controlled trials.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Humanos , Artéria Poplítea , Sirolimo , Resultado do Tratamento , Angioplastia , Artéria Femoral/cirurgia , Doença Arterial Periférica/cirurgia , Paclitaxel , Materiais Revestidos Biocompatíveis
2.
Zentralbl Chir ; 144(5): 451-459, 2019 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-30537787

RESUMO

True visceral artery aneurysms (VAA) and visceral artery pseudoaneurysms (VAPA) are located in the celiac trunk, the superior mesenteric artery and inferior mesenteric artery. In addition to surgical treatment, endovascular embolisation therapy of visceral aneurysms and pseudoaneurysms is an alternative interventional method that has developed precipitously over the last two decades and is considered a first-choice method in many centres. The procedure is characterised by a high technical success rate with a low complication rate. This article presents the basic principles of endovascular treatment and discusses the indications and limitations of the procedure.


Assuntos
Falso Aneurisma , Aneurisma , Procedimentos Endovasculares , Aneurisma/terapia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Vísceras
3.
Ultrasound Int Open ; 4(4): E131-E135, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30374471

RESUMO

OBJECTIVES: To date, the reliability of ultrasound for the quantitative assessment of pleural effusion has been limited. In the following study, an easy and cost-effective bedside ultrasound method was developed and investigated for specific use in the intensive care unit (ICU). METHODS: 22 patients (median age: 58.5 years, range: 37-88 years, 14 men and 8 women) with a total of 31 pleural effusions were examined in the ICU. The inclusion criterion was complete visualization of the effusion on chest computed tomography (CT). The ultrasound (US) examination was performed less than 6 h after the diagnostic CT scan. The pleural effusion volume was calculated volumetrically from the CT scan data. Within 4.58 +/- 2.87 h after the CT scan, all patients were re-examined with US in the ICU. The fluid crescent's thickness was measured between each intercostal space (ICS) with the patient in a supine position and a 30° inclination of the torso. The US measurements were compared to the calculated CT volumes using regression analysis, resulting in the following formula: V=13.330 x ICS6 (V=volume of the effusion [ml]; ICS6=sonographic measurement of the thickness of the liquid crescent [mm] in the sixth ICS). RESULTS: A significant correlation between the sonographically measured and the CT-calculated volumes was best observed for the sixth ICS (R2=0.589; ICC=0.7469 with p<0.0001 and a 95% CI of 0.5364-0.8705). CONCLUSION: The sonographic assessment of pleural effusions in a supine position and a 30° inclination of the torso is feasible for the volumetric estimation of pleural effusion. This is especially true for ICU patients with severe primary diseases and orthopnea who are unable to sit upright or lie flat.

4.
Zentralbl Chir ; 142(5): 470-480, 2017 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-29078242

RESUMO

Aim Percutaneous transluminal angioplasty (PTA) is a well-accepted method to re-establish patency in stenotic and reoccluded vessels. One tool to improve results may be to use paclitaxel drug-coated balloon (DCB) catheters. This systematic review investigates whether there is a class effect among different DCBs. Methods The primary endpoint was "Freedom from Target Lesion Revascularisation" (FfTLR) after 12 months. A systematic literature search was performed in PubMed and risk of bias was assessed of the included trials. Efficacy of DCB vs. POBA (plain old balloon angioplasty) in binary outcomes was investigated with relative risks and number needed to treat (NNT). Results Ten trials including 1835 patients and investigating six different DCB were identified. A high risk of bias was found in these studies. There was a lower Late Lumen Loss at six months and a higher FfTLR and primary patency at one year after DCB-treatment. However, results varied greatly with NNTs ranging from three to thirty-three. Overall, there were no differences in ABI- and Rutherford-Outcome as well as incidence of adverse events. Conclusion Tested DCBs were able to improve PTA results at one year. There were large differences in efficacy between different DCB. A class effect cannot be confirmed yet. There is a risk of overestimating the effect of DCBs due to the high risk of bias in the included trials.


Assuntos
Angioplastia com Balão/instrumentação , Arteriopatias Oclusivas/terapia , Paclitaxel/administração & dosagem , Desenho de Equipamento , Humanos
5.
J Med Case Rep ; 8: 89, 2014 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-24597952

RESUMO

INTRODUCTION: Pneumomediastinum is known to occur during labor. Patients typically present with chest pain and symptoms may be suspicious, for example of pulmonary embolism or aortic dissection. The condition itself, however, is rather harmless and self-limiting.Takotsubo cardiomyopathy is associated with psychologically or physiologically stressful events and its symptoms mimic myocardial infarction. Yet, symptoms often improve quickly as the initially impaired cardiac function is usually restored within days or weeks.Although the initial presentation of the patient in this case report was dramatic, the clinical course was positive and the patient could be quickly dismissed in a good general condition. To the best of our knowledge, no presentation of a combined occurrence of postpartum pneumomediastinum and reverse (inverted) takotsubo cardiomyopathy exists. CASE PRESENTATION: We present the case of a 30-year-old Caucasian woman with sudden onset of thoracic back and chest pain approximately 24 hours after an otherwise unremarkable vaginal delivery. A contrast-enhanced chest computed tomography showed cervical and mediastinal emphysema without proof for pulmonary embolism or aortic dissection. She received a symptomatic analgesic treatment and was dismissed to the obstetrics department for monitoring.Within hours, slightly increased levels of troponin I were observed without corresponding electrocardiography changes. Immediate cardiac catheterization and a cardiovascular magnetic resonance imaging (performed within 24 hours) revealed basal to midventricular hypokinesia, but were otherwise unremarkable. A low-dose treatment for congestive heart failure was initiated, under which symptoms subsided within days. She was dismissed after 12 days in a good general condition. CONCLUSIONS: Although the clinical presentation of the combination of the diseases initially was dramatic, the prognosis is positive. In the context of the preceding delivery, knowledge about the postpartum pneumomediastinum lets the radiologist of the emergency department quickly make this diagnosis. The takotsubo cardiomyopathy, however, needs broader diagnostics to not miss intervention-requiring causes.

6.
J Vasc Interv Radiol ; 22(8): 1149-52, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21550821

RESUMO

PURPOSE: To evaluate the feasibility and complications of percutaneous push-through gastrostomy via a computed tomography (CT)--guided gastropexy. MATERIALS AND METHODS: From January 2005 to March 2008, 14 patients in whom an oropharyngeal passage with an endoscope was impossible received a gastrostomy using the push-through technique. To attach the stomach against the abdominal wall, a CT-guided gastropexy was performed in all patients before the gastrostomy. The initial gastric tube was replaced with a short, low-profile gastric tube 2 weeks after the gastrostomy procedure. Patients were monitored for complications and survival for 6 months. RESULTS: The CT-guided dual gastropexy and percutaneous push-through gastrostomy was successfully inserted in all patients. Six months follow-up of the patients revealed only minor complications: one gastrostomy leakage and two local wounds. CONCLUSIONS: CT-guided dual gastropexy combined with the push-type gastrostomy technique is practical and safe in patients in whom an oropharyngeal passage with an endoscope is impossible and represents an alternative method of gastric fixation for radiologically placed gastrostomy tubes.


Assuntos
Neoplasias Esofágicas/complicações , Gastropexia/métodos , Gastrostomia/métodos , Neoplasias Orofaríngeas/complicações , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X , Progressão da Doença , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Técnicas de Sutura , Resultado do Tratamento
7.
Int J Comput Assist Radiol Surg ; 6(5): 713-9, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21416136

RESUMO

PURPOSE: The goal of this study was to investigate the impact of reduced k-space sampling rates on the visualization of a moving MR-compatible puncture needle and to demonstrate the feasibility of keyhole imaging in interventional magnetic resonance imaging (MRI). MATERIAL AND METHODS: All experiments were performed in an open 1.0 Tesla MRI. MR images of a moving puncture needle were taken with different keyhole sampling rates from 15-100%, in 10% increments. The needle was submerged in a water-filled basin and was imaged in motion with a T1-weighted gradient-echo sequence with an initial acquisition rate of 1.4 s per image. An apparatus operated by a compressor unit enabled needle rotation and ensured reproducible needle movements. The median forward velocity of the needle tip was 2 cm/s. To evaluate the depiction of the needle, artifact diameter of the needle, contrast-to-noise ratio (CNR), and needle tip profiles (delineation) were measured. RESULTS: The needle position was determined with an longitudinal error of 3 mm and a transverse error of 0.8 mm with respect to the needle's orientation and the theoretically calculated trajectory. No significant correlation was found between the CNR and velocity. A reduction of k-space update rates caused neither a significant reduction of CNR nor a significant increase in artifact diameter or blurring of the needle profile. CONCLUSION: The application of keyhole imaging with update rates of greater than 15% is sufficient for the MR guidance of interventions with an signal-to-noise ratio >9 of the surrounding tissue and a target accuracy of >1 mm. Keyhole imaging can increase temporal resolution while ensuring unimpaired spatial resolution and image quality of the depicted instrument.


Assuntos
Imagem por Ressonância Magnética Intervencionista/instrumentação , Agulhas , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Aceleração , Algoritmos , Desenho de Equipamento , Humanos , Imagem por Ressonância Magnética Intervencionista/métodos , Controle de Qualidade , Intensificação de Imagem Radiográfica/instrumentação , Sensibilidade e Especificidade
8.
J Vasc Access ; 12(1): 17-20, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21140360

RESUMO

PURPOSE: A prospective, randomized-controlled trail was conducted to evaluate the effectiveness of securing tunneled hemodialysis (HD) catheters with sutureless StatLock attachment devices (Bard Access Systems) compared to traditional suture fixation. METHODS: At a university teaching hospital 72 patients with chronic renal failure received cuffed tunneled HD catheters. In the study group (n=36) the HD catheters were secured with a sutureless StatLock attachment device, whereas the control group HD catheters were fixated with sutures only. The intended intermediate use of the tunneled HD catheters was 42 ± 7 days until the arteriovenous fistula was sufficient. All catheters were placed by an interventional radiologist using ultrasound for the puncture of the internal jugular vein. We evaluated the success and complication rate of tunneled catheter implantation. RESULTS: The primary success rate for implantation of HD catheters was 100%. There was an overall complication rate of 8.3% in the study group (one hematoma in the subcutaneous catheter tract and two central venous thromboses). In the control group the overall complication rate was 13.9% (two hematomas, one central venous thrombosis and two catheter displacements). The two catheter displacements required a HD catheter exchange. In addition, four local irritations at the HD catheter entry site were seen only in the control group and were rated as minor complications. CONCLUSIONS: The sutureless placement technique is safe and effective with a low complication rate, and is superior to the traditional suture fixation of tunneled catheters.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Falência Renal Crônica/terapia , Diálise Renal , Técnicas de Sutura , Idoso , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Remoção de Dispositivo , Desenho de Equipamento , Feminino , Hematoma/etiologia , Hospitais de Ensino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Trombose Venosa Profunda de Membros Superiores/etiologia
9.
Cardiovasc Intervent Radiol ; 33(2): 417-20, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19504152

RESUMO

Long-term utilization of central venous catheters (CVCs) for parenteral nutrition has a high incidence of central venous complications including infections, occlusions, and stenosis. We report the case of a 31-year-old woman presenting with a malabsorption caused by short gut syndrome due to congenital aganglionic megacolon. The patient developed a chronic occlusion of all central neck and femoral veins due to long-term use of multiple CVCs over more than 20 years. In patients with central venous occlusion and venous transformation, the implantation of a totally implanted port system by accessing collateral veins is an option to continue long-term parenteral nutrition when required. A 0.014-in. Whisper guidewire (Terumo, Tokyo) with high flexibility and steerability was chosen to maneuver and pass through the collateral veins. We suggest this approach to avoid unfavorable translumbar or transhepatic central venous access and to conserve the anatomically limited number of percutaneous access sites.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateterismo/métodos , Síndrome do Intestino Curto/terapia , Trombose Venosa/etiologia , Trombose Venosa/terapia , Adulto , Cateterismo Venoso Central/métodos , Cateteres de Demora/efeitos adversos , Circulação Colateral/fisiologia , Nutrição Enteral/efeitos adversos , Nutrição Enteral/métodos , Falha de Equipamento , Feminino , Seguimentos , Humanos , Flebografia/métodos , Medição de Risco , Síndrome do Intestino Curto/diagnóstico , Resultado do Tratamento , Grau de Desobstrução Vascular , Trombose Venosa/diagnóstico por imagem
10.
Cardiovasc Intervent Radiol ; 32(5): 975-9, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19085032

RESUMO

The purpose of this study was to evaluate whether low-profile totally implanted central venous port systems can reduce the late complication of skin perforation. Forty patients (age, 57 +/- 13 years; 22 females, 18 males) were randomized for the implantation of a low-profile port system, and another 40 patients (age, 61 +/- 14 years; 24 females, 16 males) received a regular port system as control group. Indications for port catheter implantation were malignant disease requiring chemotherapy. All port implantations were performed in the angiography suite using sonographically guided central venous puncture and fluoroscopic guidance of the catheter placement. Procedure time, number of complications (procedure-related immediate, early, and late complications), and number of explantations were assessed. Follow-up was performed for 6 months. All port implantations were successfully completed in both study groups. There were two incidents of skin perforation observed in the control group. One skin perforation occurred 13 weeks and the other 16 weeks after port implantation (incidence, 5%) in patients with regular-profile port systems. Two infections were observed, one port infection in each study group. Both infections were characterized as catheter-related infections (infection rate: 0.15 catheter-related infections per 1000 catheter days). In conclusion, low-profile port systems can be placed as safely as traditional chest ports and reduce the risk of developing skin perforations, which occurs when the port system is too tight within the port pocket.


Assuntos
Cateterismo Venoso Central/métodos , Antineoplásicos/administração & dosagem , Cateterismo Venoso Central/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/tratamento farmacológico , Punções , Radiografia Intervencionista , Infecção da Ferida Cirúrgica/etiologia , Resultado do Tratamento , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...