Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Ophthalmic Res ; 66(1): 1006-1013, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37285822

RESUMO

INTRODUCTION/PURPOSE: The aim of this study was to compare two surgical revision techniques in failed trabeculectomies after 6 months. METHODS: Patients diagnosed with open-angle glaucoma who underwent trabeculectomy in at least one eye with uncontrolled intraocular pressure (IOP) after trabeculectomy performed at least 6 months before were enrolled in this prospective trial. All participants underwent a complete ophthalmological examination at baseline. Randomization was performed to one eye per patient to double-masked trabeculectomy revision or needling. Patients were examined on the first day, 7 days, 14 days, and then monthly until completing 1 year after surgical intervention. All follow-up visits included the following: patients reported ocular and systemic events, best-corrected visual acuity, IOP, slit-lamp examination, and optic disc evaluation for cup-to-disc ratio. Gonioscopy and stereoscopic optic disc photographs were taken at baseline and 12 months. After 1-year, the IOP and number of medications were compared between the groups. Absolute success criteria in the study were IOP <16 mm Hg, for 2 consecutive measurements without using a hypotensive medication. RESULTS: Forty patients were included in this study. Among them, 38 completed 1-year follow-up (18 in revision group and 20 in needling group). The age ranged from 21 to 86 years, with a mean of 66.82 ± 13.44. At baseline, the average IOP was 21.64 ± 5.12 mm Hg (range from 14 to 38 mm Hg) in the entire group. All patients were using at least two classes of hypotensive eye drops, and 3 patients were using oral acetazolamide. The mean use of hypotensive eye drop medications was 3.11 ± 0.67 at the baseline for the entire group. In the present study, 58% of the patients presented complete success, 18% qualified success, and 24% failed in both groups. After 1-year treatment, both techniques were similar for IOP parameters and also for number of medications (p = 0.834 and p = 0.433, respectively). Regarding intra- or postoperative complications, one patient in each group needed a new surgical intervention, one in the needling group due to shallow anterior chamber and one in the revision group due to spontaneous Seidel sign, and one patient in the needling group underwent posterior revision due to fail. CONCLUSIONS: Both techniques were safe and effective for IOP control after 1 year of follow-up in patients who underwent to trabeculectomy more than 6 months before.


Assuntos
Glaucoma de Ângulo Aberto , Trabeculectomia , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Glaucoma de Ângulo Aberto/cirurgia , Estudos Prospectivos , Pressão Intraocular , Trabeculectomia/métodos , Tonometria Ocular , Estudos Retrospectivos , Resultado do Tratamento
2.
Sci Rep ; 13(1): 5023, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36977700

RESUMO

This prospective study aimed to compare vascular parameters (endothelin-1 [ET-1] blood levels, laser Doppler imaging [LDI] of distal phalanxes, and nailfold capillaroscopy) between open-angle glaucoma patients with low- and high-tension optic disc hemorrhages (LTDH and HTDH, respectively). The 33 enrolled patients (mean age, 62.3 ± 13 years) were classified as LTDH or HTDH if they presented at the time of DH detection an intraocular pressure (IOP) < 16 mmHg or ≥ 16 mmHg, respectively. Demographic and ophthalmological data, ET-1 concentrations, LDI (before and 1, 10, and 20 min after cold stimulation), and nailfold capillaroscopy findings were evaluated. The ET-1 blood level was 65% higher in the LTDH (2.27 ± 1.46 pg/ml) than in the HTDH (1.37 ± 0.57 pg/ml; p = 0.03) group. Moreover, there was a statistically significant negative correlation between ET-1 blood concentration and IOP at the time of DH detection (r = -0.45, p = 0.02). Blood flow measurements 10 and 20 min after cold stimulation were lower in the LTDH group than in the HTDH group (p < 0.01). Patients developing DH with lower IOPs have higher ET-1 blood levels and more peripheral vascular dysfunction as estimated by LDI than those with higher IOPs. These findings suggest that distinct underlying mechanisms may be involved in patients developing DH within different IOP ranges.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Glaucoma de Baixa Tensão , Disco Óptico , Doenças do Nervo Óptico , Idoso , Humanos , Pessoa de Meia-Idade , Endotelina-1 , Pressão Intraocular , Estudos Prospectivos , Hemorragia Retiniana/diagnóstico , Campos Visuais
4.
Ophthalmic Res ; 64(3): 405-410, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32942276

RESUMO

INTRODUCTION: This study aimed to evaluate the characteristics of the filtering bleb in failed late trabeculectomy and the agreement between glaucoma specialist assessment and anterior segment-optical coherence tomography (AS-OCT) system assessment in terms of the presence of subconjunctival fluid in the filtering bleb. METHODS: Patients with a diagnosis of glaucoma who were scheduled to undergo trabeculectomy in at least one eye and with uncontrolled intraocular pressure (IOP) were enrolled. All participants underwent a complete ophthalmological examination. The presence of fluid under the filtering bleb was first evaluated by a glaucoma specialist using biomicroscopy evaluation and then using the OCT 1000 AS-OCT Version 3.0.1.8 (Carl Zeiss Meditec, Dublin, CA, USA) system. A Kappa statistical test was used to evaluate the agreement between AS-OCT and the examiner. The correlation between conjunctiva and tenon thickness and clinical parameters was also assessed. RESULTS: Forty eyes of 40 patients were evaluated in this study. The ages ranged from 21 to 86 years, with a mean of 66.55 ± 12.33. The average IOP was 21.20 ± 4.44 mm Hg (range 14-38 mm Hg) in the entire group. The mean thickness of the conjunctiva and tenon was 302.03 ± 406.76 µm (range 251-1,616 µm). There was a significant negative correlation between the mean thickness of the conjunctiva and tenon and IOP (p = 0.045; confidence interval = -0.558, 0.024). Additionally, there was a significant negative correlation between the mean thickness of the conjunctiva and tenon, and the number of medications used at baseline (p = 0.043; confidence interval = -0.538, 0.051). There was significant negative correlation between the horizontal measurement of the bleb and the use of glaucoma medications (p = 0.017; confidence interval = -0.560, 0.004). A total of 26 patients were determined to have fluid by the examiner (glaucoma expert), and the presence of fluid in AS was confirmed in 19 patients by AS-OCT. Of the 14 patients who were determined to have an absence of fluid, this was confirmed by AS-OCT in 7 patients (Kappa = 0.231; agreement of 65.00%). CONCLUSION: There is fair agreement between glaucoma specialist assessment and AS-OCT assessment in terms of the presence of fluid in trabeculectomy. Our findings highlight the importance of AS-OCT in some patients before deciding upon a new intervention.


Assuntos
Glaucoma , Trabeculectomia , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Segmento Anterior do Olho/diagnóstico por imagem , Túnica Conjuntiva/diagnóstico por imagem , Glaucoma/diagnóstico , Glaucoma/cirurgia , Pressão Intraocular , Tomografia de Coerência Óptica
5.
J Glaucoma ; 30(6): 532-536, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33149106

RESUMO

PURPOSE: To determine visual field findings in Boston type 1-KPro (BI-KPro) patients without glaucoma. Characterize normal threshold values and global indices using standard automated perimetry and characterize visual field amplitude using Goldmann's manual perimetry. METHODS: This cross-sectional prospective noninterventional study included patients (n=6 patients, 6 eyes) with BI-KPro who had normal optical coherence tomography and fundoscopic evaluation of the optic disc and retina. None had a previous history of glaucoma. Visual acuity, reliable and reproducible standard automated perimetry (24-2 and 30-2), and manual perimetry examinations were obtained from all patients. Each patient answered the National Eye Institute Visual Function Questionnaire, and the results were correlated with visual field indices. RESULTS: The mean visual acuity was 0.35±0.31 logMAR (0.84 to 0.10). All visual fields had good reliability indices. The standard automated perimetry mean deviation values were -7.25±3.63 decibels (dB) and -7.75±3.23 (24-2 and 30-2 values, respectively), whereas pattern SD values were 2.72±0.82 and 3.30±1.13 (24-2 and 30-2, respectively). The manual visual field mean values of the 4 quadrants (superior, temporal, inferior, and nasal), were 39.7±4.5, 61.8±6.2, 54.0±4.3, and 48.2±7.6 degrees, respectively. The authors found a significant correlation between the VFQ-25 indexes of general sight and close-range activities with the values of total deviation at 10 degrees. VFQ-25 peripheral vision indexes also correlated significantly with values of total deviation at 30 degrees (outermost locations in the 30-degree area). CONCLUSIONS: Patients with BI-KPro presented reliable and reproductive visual field measurements. The authors found a consistent reduction in visual field extension and a global sensitivity reduction in these patients. Despite visual field changes, our patients had a good quality of life scores. Overall, these results could be useful to improve early glaucoma diagnosis and to follow-up BI-KPro patients.


Assuntos
Doenças da Córnea , Glaucoma , Córnea , Estudos Transversais , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Estudos Prospectivos , Próteses e Implantes , Qualidade de Vida , Reprodutibilidade dos Testes , Transtornos da Visão/diagnóstico , Testes de Campo Visual , Campos Visuais
6.
J Glaucoma ; 29(5): 393-400, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32079996

RESUMO

PRECIS: Glaucoma patients presented a decreased occipital pole surface area in both hemispheres. Moreover, these parameters are independently correlated with functional and structural ocular parameters. PURPOSE: The purpose of this study was to evaluate structural brain abnormalities in glaucoma patients using 3-Tesla magnetic resonance imaging and assess their correlation with associated structural and functional ocular findings. PATIENTS AND METHODS: This cross-sectional prospective study included 30 glaucoma patients and 18 healthy volunteers. All participants underwent standard automated perimetry, spectral-domain optical coherence tomography, and 3.0-Tesla magnetic resonance imaging. RESULTS: There was a significant difference between the surface area of the occipital pole in the left hemisphere of glaucoma patients (mean: 1253.9±149.3 mm) and that of control subjects (mean: 1341.9±129.8 mm), P=0.043. There was also a significant difference between the surface area of the occipital pole in the right hemisphere of glaucoma patients (mean: 1910.5±309.4 mm) and that of control subjects (mean: 2089.1±164.2 mm), P=0.029. There was no significant difference between the lingual, calcarine, superior frontal, and inferior frontal gyri of glaucoma patients and those of the control subjects (P>0.05 for all comparisons). The surface area of the occipital pole in the left hemisphere was significantly correlated with perimetry mean deviation values, visual acuity, age, and retinal nerve fiber layer thickness (P=0.001, <0.001, 0.010, and 0.006, respectively). The surface area of the occipital pole in the right hemisphere was significantly correlated with perimetry mean deviation values, visual field indices, visual acuity, age, and retinal nerve fiber layer thickness (P<0.001, 0.007, <0.001, 0.046, and <0.001, respectively). CONCLUSION: Glaucoma patients presented a decreased occipital pole surface area in both hemispheres that independently correlated with functional and structural ocular parameters.


Assuntos
Encefalopatias/diagnóstico por imagem , Glaucoma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Lobo Occipital/diagnóstico por imagem , Adulto , Idoso , Encefalopatias/fisiopatologia , Estudos Transversais , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Lobo Occipital/fisiopatologia , Estudos Prospectivos , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Acuidade Visual/fisiologia , Testes de Campo Visual , Campos Visuais/fisiologia
7.
J Ophthalmol ; 2016: 5317371, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26955483

RESUMO

Patients with glaucoma showed to have higher daytime sleepiness measured by Epworth sleepiness scale. In addition, this symptom was associated with pupillary reflex and polysomnography parameters. These ipRGC functions might be impaired in patients with glaucoma, leading to worse quality of life.

8.
PLoS One ; 10(5): e0126362, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25969982

RESUMO

PURPOSE: To evaluate the functional magnetic resonance imaging (fMRI) response to binocular visual stimulation and the association thereof with structural ocular findings and psychophysical test results in patients with glaucoma, and controls. METHODS: Cross-sectional study. Participants underwent a complete ophthalmic examination, including Humphrey 24-2 visual field (VF) testing and optical coherence tomography. Binocular VF in each quadrant was determined using an integrated method. Patients with glaucoma were assigned to three subgroups: initial, asymmetrical and severe glaucoma. Regions of interest (ROIs) were determined anatomically. fMRI (3 T) was performed using a bilaterally presented polar angle stimulus, and the accompanying changes in blood oxygen level-dependent (BOLD) signals were obtained from the occipital poles and calcarine ROIs. We used generalized estimation equation models to compare anatomical and functional data between the groups. RESULTS: A total of 25 subjects were enrolled, of whom 17 had glaucoma and 8 were controls. Significant associations between quadrant binocular VF sensitivities and fMRI responses were found in the occipital pole ROIs (p = 0.033) and the calcarine ROIs (p = 0.045). In glaucoma severity subgroup analysis, retinal nerve fiber layer (RNFL) thickness was associated with the BOLD response of the calcarine and occipital pole ROIs (p = 0.002 and 0.026, respectively). The initial and asymmetrical glaucoma subgroups had similar binocular VF sensitivities and RNFL thicknesses, but distinct BOLD responses. CONCLUSIONS: The response of the visual cortex to binocular stimulation was associated with binocular VF sensitivity. RNFL thickness was associated with the BOLD response of the calcarine and occipital pole ROIs.


Assuntos
Glaucoma/patologia , Glaucoma/fisiopatologia , Córtex Visual/fisiopatologia , Adulto , Idoso , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Nervo Óptico/patologia , Estimulação Luminosa , Psicofísica , Tomografia de Coerência Óptica , Campos Visuais
9.
Ophthalmology ; 122(6): 1139-48, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25858174

RESUMO

PURPOSE: To use the pupillary light reflex and polysomnography to evaluate the function of intrinsically photosensitive retinal ganglion cells (ipRGCs) and to correlate this function with structural damage in glaucoma. DESIGN: Cross-sectional study. PARTICIPANTS: A study was conducted on both eyes of 45 participants (32 patients with glaucoma and 13 healthy subjects). METHODS: For the pupillary reflex evaluation, patients were tested in the dark using a Ganzfeld system (RETIport; Roland Consult, Brandenburg, Germany); pupil diameter was measured with an eye tracker system. To preferentially stimulate ipRGCs, we used a 1-second 470-nm flash with a luminance of 250 cd/m(2). To stimulate different retinal photoreceptors, we used a 1-second 640-nm flash with a luminance of 250 cd/m(2). All of the subjects underwent polysomnography. Subjects underwent standard automated perimetry and optical coherence tomography (Cirrus HD-OCT; Carl Zeiss Meditec Inc, Dublin, CA). MAIN OUTCOME MEASURES: Correlations between ipRGC activity, as measured by the pupillary light reflex, and polysomnography parameters, and correlations between retinal nerve fiber layer (RNFL) thickness and the pupillary light reflex and polysomnography parameters. RESULTS: The mean patient ages in the healthy and glaucoma groups were 56.8±7.8 years and 61.5±11.6 years, respectively (P = 0.174). Patients with glaucoma had significantly lower average total sleep time, sleep efficiency, and minimum oxyhemoglobin saturation compared with the healthy subjects (P = 0.008, P = 0.002, and P = 0.028, respectively). Patients with glaucoma had significantly higher arousal durations after falling asleep and more periodic limb movements (P = 0.002 and P = 0.045, respectively). There was an inverse correlation between the rapid eye movement latency and the peak of the pupillary response to the blue flash (P = 0.004). The total arousals were inversely correlated with the sustained blue flash response (P = 0.029). The RNFL thickness was associated with the peak and sustained responses to the blue flash (P < 0.001 for both comparisons); however, RNFL thickness was only associated with the mean oxygen desaturation index among the polysomnography parameters (P = 0.023). CONCLUSIONS: This study demonstrated that decreased ipRGC function caused by glaucoma affected pupillary response and sleep quality.


Assuntos
Glaucoma de Ângulo Aberto/fisiopatologia , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Transtornos do Sono-Vigília/fisiopatologia , Idoso , Anti-Hipertensivos/uso terapêutico , Estudos Transversais , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/tratamento farmacológico , Gonioscopia , Humanos , Pressão Intraocular , Luz , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Polissonografia , Reflexo Pupilar/fisiologia , Transtornos do Sono-Vigília/diagnóstico , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia , Testes de Campo Visual , Campos Visuais/fisiologia
10.
Invest Ophthalmol Vis Sci ; 55(12): 7997-8005, 2014 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-25406281

RESUMO

PURPOSE: To assess the integrity of intrinsically photosensitive retinal ganglion cells (ipRGCs) using the pupillary light reflex in glaucoma patients. METHODS: A cross-sectional study was conducted, including 76 eyes from 38 patients with primary open-angle glaucoma and 36 eyes from 18 control subjects. The patients were tested in the dark with light stimuli using the Ganzfeld system, and the pupil diameter was measured with the assistance of an eye tracker consisting of two infrared cameras fit to an eyeglass frame. To preferentially stimulate ipRGCs, we used a 1-second 470-nm flash with a luminance of 250 cd/m(2). To stimulate different retinal photoreceptors (cones and rods), we used a 1-second 630-nm flash with a luminance of 250 cd/m(2). Standard automated perimetry (SAP), matrix frequency-doubling technology (FDT), and high-definition optical coherence tomography (Cirrus HD-OCT) were also performed. The correlation between the ipRGC-mediated sustained response following the pupillary light reflex and the structural and functional changes in glaucoma patients was analyzed using generalized estimating equation. RESULTS: An association was observed between the average retinal nerve fiber layer (RNFL) thickness, as measured by Cirrus HD-OCT, and the sustained pupillary response to the blue flash (P = 0.024). The severity of glaucoma, based on the mean deviation of SAP (Hodapp-Anderson-Parrish system), was also associated with the sustained response to the blue flash (P = 0.006). CONCLUSIONS: This study showed a correlation between the mean RNFL thickness and the pupillary light response. A decrease in the number of ipRGCs is potentially related to the reduced RNFL thickness.


Assuntos
Glaucoma de Ângulo Aberto/fisiopatologia , Pupila/efeitos da radiação , Células Ganglionares da Retina/patologia , Idoso , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa/métodos , Estudos Prospectivos , Tomografia de Coerência Óptica , Testes de Campo Visual , Campos Visuais/fisiologia
11.
Clin Exp Ophthalmol ; 40(7): 682-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22429725

RESUMO

BACKGROUND: To investigate the association between corneal biomechanics and optic nerve head morphology in newly diagnosed primary open-angle glaucoma patients. DESIGN: Hospital based prospective study. PARTICIPANTS: Forty-two untreated newly diagnosed primary open-angle glaucoma patients. METHODS: Patients underwent corneal hysteresis measurement using the Ocular Response Analyzer and confocal scanning laser ophthalmoscopy for optic nerve head topography evaluation. One eye was selected randomly for analysis. Data collected included age, race, gender, intraocular pressure and central corneal thickness. MAIN OUTCOME MEASURES: Multiple regression analysis (controlling for baseline intraocular pressure and disc area) was used to investigate factors associated with the following optic nerve head topographic parameters: linear cup-to-disc ratio and mean cup depth. RESULTS: Mean age of participants was 66.7 ± 11.8 years. Corneal hysteresis was the only factor significantly associated with both mean cup depth (correlation coefficient [r] = -0.34, P = 0.03) and cup-to-disc ratio (r = -0.41, P = 0.01). Central corneal thickness was significantly associated with mean cup depth (r = -0.35, P = 0.02), but not with cup-to-disc ratio (r = -0.25, P = 0.13). Although a trend towards a positive association between age and cup-to-disc ratio was identified (r = 0.26, P = 0.08), age was not significantly associated with mean cup depth (r = 0.06, P = 0.72). When comparing fellow eyes of patients with bilateral glaucoma, the eye with higher corneal hysteresis had smaller cup-to-disc ratio in 75% of the cases. CONCLUSIONS: In untreated newly diagnosed primary open-angle glaucoma patients, those with thinner corneas and mainly lower corneal hysteresis values had a larger cup-to-disc ratio and deeper cup, independently of intraocular pressure values and disc size.


Assuntos
Fenômenos Biomecânicos/fisiologia , Córnea/fisiopatologia , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular/fisiologia , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Idoso , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Lasers , Masculino , Oftalmoscopia , Doenças do Nervo Óptico/fisiopatologia , Estudos Prospectivos , Tonometria Ocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...