Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 150
Filtrar
1.
EuroIntervention ; 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39302067

RESUMO

The percutaneous treatment of structural, valvular, and non-valvular heart disease (SHD) is rapidly evolving. The Core Curriculum (CC) proposed by the EAPCI describes the knowledge, skills, and attitudes that define competency levels required by newly trained SHD interventional cardiologists (IC) and provides guidance for training centres. SHD ICs are cardiologists who have received complete interventional cardiology training. They are multidisciplinary team specialists who manage adult SHD patients from diagnosis to follow-up and perform percutaneous procedures in this area. They are competent in interpreting advanced imaging techniques and master planning software. The SHD ICs are expected to be proficient in the aortic, mitral, and tricuspid areas. They may have selective skills in either the aortic area or mitral/tricuspid areas. In this case, they must still have common transversal competencies in the aortic, mitral, and tricuspid areas. Additional SHD domain competencies are optional. Completing dedicated SHD training, aiming for full aortic, mitral, and tricuspid competencies, requires at least 18 months. For full training in the aortic area, with basic competencies in mitral/tricuspid areas, the training can be reduced to 1 year. The same is true for training in the mitral/tricuspid area, with competencies in the aortic area. The SHD IC CC promotes excellence and homogeneous training across Europe and is the cornerstone of future certifications and patient protection. It may be a reference for future CC for national associations and other SHD specialities, including imaging and cardiac surgery.

2.
EuroIntervention ; 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39207816

RESUMO

The percutaneous treatment of structural, valvular, and non-valvular heart disease (SHD) is rapidly evolving. The Core Curriculum (CC) proposed by the EAPCI describes the knowledge, skills, and attitudes that define competency levels required by newly trained SHD interventional cardiologists (IC) and provides guidance for training centres. SHD ICs are cardiologists who have received complete interventional cardiology training. They are multidisciplinary team specialists who manage adult SHD patients from diagnosis to follow-up and perform percutaneous procedures in this area. They are competent in interpreting advanced imaging techniques and master planning software. The SHD ICs are expected to be proficient in the aortic, mitral, and tricuspid areas. They may have selective skills in either the aortic area or mitral/tricuspid areas. In this case, they must still have common transversal competencies in the aortic, mitral, and tricuspid areas. Additional SHD domain competencies are optional. Completing dedicated SHD training, aiming for full aortic, mitral, and tricuspid competencies, requires at least 18 months. For full training in the aortic area, with basic competencies in mitral/tricuspid areas, the training can be reduced to 1 year. The same is true for training in the mitral/tricuspid area, with competencies in the aortic area. The SHD IC CC promotes excellence and homogeneous training across Europe and is the cornerstone of future certifications and patient protection. It may be a reference for future CC for national associations and other SHD specialities, including imaging and cardiac surgery.

3.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-39068987

RESUMO

INTRODUCTION AND OBJECTIVES: Transcatheter mitral valve replacement (TMVR) is an emerging treatment alternative for mitral valve (MV) disease in patients who were ineligible for surgical intervention or edge-to-edge repair. This study aimed to assess the short- and mid-term outcomes of this procedure. METHODS: We conducted a prospective registry to include the initial experience with symptomatic, consecutive patients who underwent TMVR using the transapical Tendyne system at 7 centers in the Iberian Peninsula. Baseline clinical and imaging data, periprocedural information, and follow-up assessments were collected at 1 month and 1 year. RESULTS: A total of 40 patients (mean age 78.5 years [76-82], 47,5% males) underwent TMVR. The majority had significant surgical risk, comorbidities, and advanced functional class. All patients had significant mitral regurgitation (MR), except for 2 with severe stenosis. Previous MV intervention and off-label indication for the procedure were present in 4 (10.0%) and 8 (20.0%) patients, respectively. Technical success was recorded in 100%, device success in 95.0%, and procedural success in 85.0% at 30-day. All-cause mortality was 2.5% and 17.5% at the 1-month and 1-year follow-up, respectively. MR reduction (≤ 1) and functional class improvement (NYHA I-II) were observed at 1 year in 93.9% and 87.9% of survivors, respectively. CONCLUSIONS: Treatment with TMVR produced enduring resolution of MV disease and notable functional enhancement at 1 year of follow-up. The procedure demonstrated a satisfactory early safety profile, although 1-year mortality remained relatively high in this high-risk population.

4.
Catheter Cardiovasc Interv ; 103(7): 1159-1164, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38639138

RESUMO

Despite progressively uncommon in Western countries, rheumatic heart disease still portrays a significant global burden. In elderly or high-surgical risk patients, plurivalvular disease may require a complex percutaneous approach. Transcatheter aortic valve implantation (TAVI) in patients with previous monoleaflet mitral prosthesis is challenging due to interference between the aortic valve and the rigid mitral mechanical prosthesis "ring." Prior cases report the use of CoreValve or Edwards Sapien aortic valves in patients with adequate mitro-aortic distance. Performing a second major procedure, such as tricuspid valve-in-valve (TVIV), sequentially during a single percutaneous intervention, increases treatment complexity. An 83-year-old woman with rheumatic heart disease, with previous implantation of a Bjork-Shiley monoleaflet mitral prosthesis, and Carpentier-Edwards 29 tricuspid bioprosthesis presented with decompensated heart failure due to severe aortic stenosis and tricuspid bioprosthesis stenosis. After HeartTeam discussion, the patient was deemed as inoperable due to a prohibitive surgical risk. As an alternative, a TAVI (Navitor FlexNav) and a transcatheter TVIV replacement (Edwards Sapiens 3 Ultra) were discussed and proposed, with both techniques being performed sequentially in a single procedure. TAVI in a patient with a previous monoleaflet mitral mechanical prosthesis and TVIV may be a feasible approach in inoperable patients with plurivalvular disease.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Desenho de Prótese , Cardiopatia Reumática , Substituição da Valva Aórtica Transcateter , Valva Tricúspide , Humanos , Feminino , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Valva Tricúspide/fisiopatologia , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/fisiopatologia , Cardiopatia Reumática/cirurgia , Cardiopatia Reumática/terapia , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Recuperação de Função Fisiológica , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico por imagem
5.
Am Heart J ; 270: 86-94, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38309610

RESUMO

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Valva Aórtica/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Ponte de Artéria Coronária , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
6.
Artigo em Inglês | MEDLINE | ID: mdl-38262740

RESUMO

BACKGROUND AND AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing transcatheter aortic valve intervention (TAVI). METHODS: We followed the European Society of Cardiology (ESC) methodology for the development of QIs. Key domains were identified by constructing a conceptual framework for the delivery of TAVI care. A list of candidate QIs were developed by conducting a systematic review of the literature. A modified Delphi method was then used to select the final set of QIs. Finally, we mapped the QIs to the EuroHeart Data Standards for TAVI to ascertain the extent to which the EuroHeart TAVI registry captures information to calculate the QIs. RESULTS: We formed an international group of experts in quality improvement and TAVI, including representatives from the European Association of Percutaneous Cardiovascular Interventions, the European Association of Cardiovascular Imaging and the Association of Cardiovascular Nursing & Allied Professions. In total, 27 QIs were selected across eight domains of TAVI care, comprising 22 main (81%) and five secondary (19%) QIs. Of these, 19/27 (70%) are now being utilised in the EuroHeart TAVI registry. CONCLUSION: We present the 2023 ESC QIs for TAVI, developed using a standard methodology and in collaboration with ESC Associations. The EuroHeart TAVI registry allows calculation of the majority of the QIs, which may be used for benchmarking care and quality improvement initiatives.

7.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38180419

RESUMO

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pandemias , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Resultado do Tratamento , COVID-19/epidemiologia , Sistema de Registros , Fatores de Risco
8.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37138103

RESUMO

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Sistema de Registros , Desenho de Prótese
9.
Clin Res Cardiol ; 113(1): 86-93, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37391628

RESUMO

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic valve stenosis in elderly patients, but there is uncertainty on their long-term effectiveness. We aimed to assess the long-term outcome of patients undergoing TAVI with the Portico valve. METHODS: We retrospectively collected the data on patients in whom TAVI with Portico was attempted from 7 high-volume centres. Only patients theoretically eligible for 3 or more years of follow-up were included. Clinical outcomes, including death, stroke, myocardial infarction, reintervention for valve degeneration and hemodynamic valve performance were systematically assessed. RESULTS: A total of 803 patients were included, with 504 (62.8%) women, mean age of 82 years, median EuroSCORE II of 3.1%, and 386 (48.1%) subjects at low/moderate risk. The median follow-up was 3.0 years (3.0; 4.0). The composite of death, stroke, myocardial infarction, and reintervention for valve degeneration occurred in 37.5% (95% confidence interval: 34.1-40.9%), with all-cause death in 35.1% (31.8-38.4%), stroke in 3.4% (1.3-3.4%), myocardial infarction in 1.0% (0.3-1.5%), and reintervention for valve degeneration in 1.1% (0.6-2.1%). The mean aortic valve gradient at follow-up was 8.1 ± 4.6 mmHg, and at least moderate aortic regurgitation was present in 9.1% (6.7-12.3%). Independent predictors of major adverse events or death were: peripheral artery disease, chronic obstructive pulmonary disease, estimated glomerular filtration rate, atrial fibrillation, prior pacemaker implantation, EuroSCORE II, and reduced left ventricular ejection fraction (all p < 0.05). CONCLUSIONS: Portico use is associated with favorable long-term clinical outcomes. Clinical outcomes were largely impacted by baseline risk factors and surgical risk.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia , Acidente Vascular Cerebral/etiologia
10.
Hellenic J Cardiol ; 2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37689181

RESUMO

OBJECTIVE: Aortic stenosis and coronary artery disease (CAD) are frequently associated. The preprocedural evaluation and indications for treatment in patients undergoing transcatheter aortic valve intervention (TAVI) remain controversial. This study sought to 1) determine the prevalence and angiographic characteristics of CAD in TAVI candidates, along with revascularization patterns, and 2) to evaluate the impact of the presence and complexity of CAD, as well as angiography-guided percutaneous coronary intervention, on prognosis after TAVI. METHODS: Single-center retrospective study from a prospectively collected institutional registry that included all patients that underwent TAVI between 2009 and 2018 and pre TAVI coronary angiography (CA) in our institution in the context of pre-procedure work-up. A multivariate analysis was performed to determine the effect of CAD and PCI on 2-year mortality. RESULTS: A total of 379 patients were included: 55 patients (14.5%) presented with normal coronary arteries, 120 (31.6%) with non-obstructive CAD, and 204 (53.8%) with obstructive CAD (the mean SxS was 8.2). Ultimately, 110 patients (29%) underwent PCI. Two-year survival after TAVI was decreased in patients with complex coronary lesions (SS > 22), while it was not affected by the overall presence of non-obstructive CAD, obstructive CAD, residual SxS, or pre-TAVI PCI of angiographically significant lesions (OR 0.631, 95%CI 0.192-1.406). CONCLUSION: In our population, the overall presence and management of obstructive CAD did not appear to impact mortality at 2 years after TAVI. Survival was decreased in patients with baseline complex coronary anatomies.

11.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37668097

RESUMO

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos
12.
Front Cardiovasc Med ; 10: 1227217, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37645516

RESUMO

Background: A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume. Aims: The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe. Materials and methods: Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice. Results: Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77-194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%). Conclusion: Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.

13.
EuroIntervention ; 19(8): 634-651, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37624587

RESUMO

Valvular heart disease (VHD) is one of the most frequent causes of heart failure (HF) and is associated with poor prognosis, particularly among patients with conservative management. The development and improvement of catheter-based VHD interventions have broadened the indications for transcatheter valve interventions from inoperable/high-risk patients to younger/lower-risk patients. Cardiogenic shock (CS) associated with severe VHD is a clinical condition with a very high risk of mortality for which surgical treatment is often deemed a prohibitive risk. Transcatheter valve interventions might be a promising alternative in this setting given that they are less invasive. However, supportive scientific evidence is scarce and often limited to small case series. Current guidelines on VHD do not contain specific recommendations on how to manage patients with both VHD and CS. The purpose of this clinical consensus statement, developed by a group of international experts invited by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) Scientific Documents and Initiatives Committee, is to perform a review of the available scientific evidence on the management of CS associated with left-sided VHD and to provide a rationale and practical approach for the application of transcatheter valve interventions in this specific clinical setting.

14.
Clin Res Cardiol ; 112(9): 1322-1330, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37337010

RESUMO

BACKGROUND AND AIM: Parenteral anticoagulation is recommended for all patients presenting with ST-segment elevation myocardial infarction (STEMI) during primary percutaneous coronary intervention (PPCI). Whether upstream anticoagulation improves clinical outcomes is not well established. We conducted a systematic review and meta-analysis of contemporary evidence on parenteral anticoagulation timing for STEMI patients. METHODS: We performed a systematic search of electronic databases (PubMed, CENTRAL, and Scopus) until December 2022. Studies were eligible if they (a) compared upstream anticoagulation with administration at the catheterization laboratory and (b) enrolled patients with STEMI undergoing PPCI. Efficacy outcomes included in-hospital or 30-day mortality, in-hospital cardiogenic shock (CS), and TIMI flow grade pre- and post-PPCI. Safety outcome was defined as in-hospital or 30-day major bleeding. RESULTS: Overall, seven studies were included (all observational), with a total of 69,403 patients. Upstream anticoagulation was associated with a significant reduction in the incidence of in-hospital or 30-day all-cause mortality (OR 0.61; 95% CI 0.45-0.81; p < 0.001) and in-hospital CS (OR 0.68; 95% CI 0.58-0.81; p < 0.001) and with an increase in spontaneous reperfusion (pre-PPCI TIMI > 0: OR 1.46; 95% CI 1.35-1.57; p < 0.001). Pretreatment was not associated with an increase in major bleeding (OR 1.02; 95% CI 0.70-1.48; p = 0.930). CONCLUSIONS: Upstream anticoagulation was associated with a significantly lower risk of 30-day all-cause mortality, incidence of in-hospital CS, and improved reperfusion of the infarct-related artery (IRA). These findings were not accompanied by an increased risk of major bleeding, suggesting an overall clinical benefit of early anticoagulation in STEMI. These results require confirmation in a dedicated randomized clinical trial.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Intervenção Coronária Percutânea/métodos , Hemorragia/induzido quimicamente , Cateterismo , Anticoagulantes/uso terapêutico , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
15.
EuroIntervention ; 19(6): 502-511, 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37203860

RESUMO

BACKGROUND: Prospective data about transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) patients are limited. AIMS: We aimed to evaluate the clinical impact of the Evolut PRO and R (34 mm) self-expanding prostheses in BAV patients and explore the impact of different computed tomography (CT) sizing algorithms in a prospective registry. METHODS: A total of 149 bicuspid patients were treated in 14 countries. The primary endpoint was the intended valve performance at 30 days. Secondary endpoints were 30-day and 1-year mortality, severe patient-prosthesis mismatch (PPM) and the ellipticity index at 30 days. All study endpoints were adjudicated according to Valve Academic Research Consortium 3 criteria. RESULTS: The mean Society of Thoracic Surgeons score was 2.6% (1.7-4.2). Type I L-R BAV was observed in 72.5% of the patients. Evolut valve sizes 29 and 34 mm were utilised in 49.0% and 36.9% of the cases, respectively. The 30-day cardiac death rate was 2.6%; the 1-year cardiac death rate was 11.0%. Valve performance at 30 days was observed in 142/149 (95.3%) patients. The mean aortic valve area post-TAVI was 2.1 (1.8-2.6) cm2, and the mean aortic gradient was 7.2 (5.4-9.5) mmHg. No patient had more than moderate aortic regurgitation at 30 days. PPM was observed in 13/143 (9.1%) surviving patients and was severe in 2 patients (1.6%). Valve function was maintained at 1 year. The mean ellipticity index remained 1.3 (interquartile range 1.2-1.4). Overall, 30-day and 1-year clinical and echocardiography outcomes were similar between the two sizing strategies. CONCLUSIONS: BIVOLUTX demonstrated a favourable bioprosthetic valve performance and good clinical outcomes after TAVI with the Evolut platform in patients with bicuspid aortic stenosis. No impact from the sizing methodology could be identified.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Válvula Aórtica Bicúspide/etiologia , Doença da Válvula Aórtica Bicúspide/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Resultado do Tratamento , Desenho de Prótese , Estudos Prospectivos , Doenças das Valvas Cardíacas/cirurgia , Estenose da Valva Mitral/cirurgia , Sistema de Registros , Morte
16.
Rev Port Cardiol ; 42(9): 787-793, 2023 09.
Artigo em Inglês, Português | MEDLINE | ID: mdl-37257584

RESUMO

INTRODUCTION AND OBJECTIVES: Randomized controlled trials comparing stress cardiac magnetic resonance (CMR) and single-photon emission computed tomography (SPECT) suggest similar diagnostic accuracy for detecting obstructive coronary artery disease (CAD). There are few data on whether this remains true in routine clinical practice. The aim of this study was to assess clinical and angiographic characteristics of patients undergoing invasive coronary angiography (ICA) after stress CMR or SPECT, and to compare their positive predictive value with published results from the CE-MARC trial. METHODS: In this retrospective tertiary-center analysis, we included 429 patients undergoing ICA after a positive stress CMR or positive SPECT performed within the previous 12 months. Obstructive CAD was defined as any coronary artery stenosis ≥50% in a vessel compatible with the ischemic territory on stress testing. RESULTS: Of the total 429 patients, 356 (83%) were referred after a positive SPECT, and 73 (17%) after a positive stress CMR. Patients did not differ according to age, cardiovascular risk factors, previous revascularization or left ventricular dysfunction, but patients with SPECT were more frequently male (p=0.046). The prevalence of obstructive CAD was similar in patients with positive SPECT vs. positive stress CMR (76.1% vs. 80.8%, respectively, p=0.385). The positive predictive values of both techniques were similar to those reported in the CE-MARC trial. CONCLUSION: In this tertiary center analysis, stress CMR and SPECT showed similar positive predictive values, comparable to those reported in the CE-MARC trial. This finding supports the emerging adoption of CMR in clinical practice for the diagnosis and management of CAD.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Masculino , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Imagem de Perfusão do Miocárdio/métodos , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
17.
EuroIntervention ; 18(17): 1418-1427, 2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-36880333

RESUMO

BACKGROUND: Initial data about the performance of the new-generation SAPIEN 3 Ultra (S3U) valve are highly promising. However, evidence about the longer-term performance and safety of the S3U is scarce. AIMS: We aimed to investigate the 1-year clinical and echocardiographic outcomes of transcatheter aortic valve implantation (TAVI) using the S3U compared with its predecessor, the SAPIEN 3 valve (S3). METHODS: The SAPIEN 3 Ultra registry included consecutive patients who underwent transfemoral TAVI at 12 European centres with the S3U or S3 between October 2016 and December 2020. One-to-one propensity score (PS) matching was performed to account for differences in baseline characteristics. The primary outcomes of interest were all-cause death and the composite of all-cause death, disabling stroke and hospitalisation for heart failure at 1 year. RESULTS: The overall study cohort encompassed 1,692 patients treated with either the S3U (n=519) or S3 (n=1,173). The PS-matched population had a total of 992 patients (496 per group). At 1 year, the rate of death from any cause was 4.9% in the S3U group and 6.3% in the S3 group (p=0.743). Similarly, there were no significant differences in the rates of the primary composite outcome (9.5% in the S3 group and 6.6% in the S3U group; p=0.162). The S3U was associated with lower rates of mild paravalvular leak (PVL) compared with the S3 (odds ratio 0.63, 95% confidence interval: 0.44 to 0.88; p<0.01). No significant differences in transprosthetic gradients were observed between the two groups. CONCLUSIONS: Compared with the S3, the S3U transcatheter heart valve was associated with similar 1-year clinical outcomes but reduced rates of mild PVL.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Sistema de Registros , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
18.
Int J Cardiol ; 379: 16-23, 2023 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-36863420

RESUMO

BACKGROUND: Sex-specific characteristics in patients with aortic stenosis and small annuli undergoing transcatheter aortic valve implantation (TAVI) might affect clinical outcomes and hemodynamics. METHODS: TAVI-SMALL 2 international retrospective registry included 1378 patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area < 400 mm2) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Women (n = 1233) were compared with men (n = 145). One-to-one propensity score (PS) matching resulted in 99 pairs. Primary endpoint was incidence of all-cause mortality. Incidence of pre-discharge severe prosthesis-patient mismatch (PPM) and its association with all-cause mortality were investigated. Binary logistic and Cox regression were performed to adjust the treatment effect for PS quintiles. RESULTS: Incidence of all-cause mortality at a median follow-up of 377 days did not differ between sex in the overall (10.3 vs. 9.8%, p = 0.842) and PS-matched (8.5 vs. 10.9%, p = 0.586) populations. After PS matching, pre-discharge severe PPM was numerically higher in women vs. men (10.2 vs. 4.3%), even though no evidence of a difference was found (p = 0.275). Within the overall population, women with severe PPM suffered a higher incidence of all-cause mortality when compared to those with less than moderate PPM (log-rank p = 0.024) and less than severe PPM (p = 0.027). CONCLUSIONS: No difference in all-cause mortality at medium-term follow-up was observed between women and men with aortic stenosis and small annuli undergoing TAVI. Incidence of pre-discharge severe PPM was numerically higher in women than men, and it was associated with increased all-cause mortality in women.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Feminino , Valva Aórtica/cirurgia , Estudos Retrospectivos , Pontuação de Propensão , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Fatores de Risco
19.
EuroIntervention ; 19(3): 256-266, 2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-36950893

RESUMO

BACKGROUND: Treatment of aortic stenosis in patients with small annuli is challenging and can result in prosthesis-patient mismatch (PPM). AIMS: We aimed to compare the forward flow haemodynamics and clinical outcomes of contemporary transcatheter valves in patients with small annuli. METHODS: The TAVI-SMALL 2 international retrospective registry included 1,378 patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2) treated with transfemoral self-expanding (SEV; n=1,092) and balloon-expandable valves (BEV; n=286) in 16 high-volume centres between 2011 and 2020. Analyses comparing SEV versus BEV and supra-annular (SAV; n=920) versus intra-annular valves (IAV; n=458) included inverse probability of treatment weighting (IPTW). The primary endpoints were the predischarge mean aortic gradient and incidence of severe PPM. The secondary endpoint was the incidence of more than mild paravalvular leak (PVL). RESULTS: The predischarge mean aortic gradient was lower after SAV versus IAV (7.8±3.9 vs 12.0±5.1; p<0.001) and SEV versus BEV implantation (8.0±4.1 vs 13.6±4.7; p<0.001). Severe PPM was more common with IAV and BEV when compared to SAV and SEV implantation, respectively, (8.8% vs 3.6%; p=0.007 and 8.7% vs 4.6%; p=0.041). At multivariable logistic regression weighted by IPTW, SAV protected from severe PPM regardless of its definition. More than mild PVL occurred more often with SEV versus BEV (11.6% vs 2.6%; p<0.001). CONCLUSIONS: In small aortic annuli, implantation of SAV and SEV was associated with a more favourable forward haemodynamic profile than after IAV and BEV implantation, respectively. More than mild PVL was more common after SEV than BEV implantation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Estenose da Valva Aórtica/cirurgia , Sistema de Registros , Resultado do Tratamento
20.
EuroIntervention ; 19(1): 37-52, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-36811935

RESUMO

Significant coronary artery disease (CAD) is a frequent finding in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI), and the management of these two conditions becomes of particular importance with the extension of the procedure to younger and lower-risk patients. Yet, the preprocedural diagnostic evaluation and the indications for treatment of significant CAD in TAVI candidates remain a matter of debate. In this clinical consensus statement, a group of experts from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) in collaboration with the European Society of Cardiology (ESC) Working Group on Cardiovascular Surgery aims to review the available evidence on the topic and proposes a rationale for the diagnostic evaluation and indications for percutaneous revascularisation of CAD in patients with severe aortic stenosis undergoing transcatheter treatment. Moreover, it also focuses on commissural alignment of transcatheter heart valves and coronary re-access after TAVI and redo-TAVI.


Assuntos
Estenose da Valva Aórtica , Cardiologia , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA