Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
World J Urol ; 22(2): 124-31, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-14986047

RESUMO

Our aim was to assess the usefulness of measuring the percentage of free prostate specific antigen (PSA) in serum in relation to reducing the number of prostate biopsies in men with benign prostate examinations and serum PSA levels between 4 and 10 ng/ml. The percentage of free PSA (Immulite) in serum was analyzed prospectively in 500 men, all of whom underwent ultrasound-guided sextant prostate biopsies. Cancer was detected in 21.4% (107/500) of the patients. Using a free PSA cutoff of < or = 23% as a criterion for performing prostate biopsy would have detected 94.4% of cancers, avoided 18.8% of benign biopsies and yielded a positive predictive value of 25.3%. The percentage of free PSA increased with prostate volume. Mean total PSA and mean free percent PSA values increased as patient age increased, influencing the calculation of cutoff values, sensitivity and specificity. PSA density had a sensitivity and specificity not significantly different than the percentage of free PSA. Measurement of the percentage of free serum PSA improves the specificity of prostate cancer detection in patients with elevated total serum PSA levels and benign prostate examinations.


Assuntos
Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Exame Físico , Valor Preditivo dos Testes , Estudos Prospectivos , Neoplasias da Próstata/patologia , Reto , Sensibilidade e Especificidade
2.
Radiother Oncol ; 49(2): 191-6, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10052886

RESUMO

BACKGROUND AND PURPOSE: Beta emitting 106Ru applicators are widely used to treat choroidal melanoma. In view of the importance of clinical applications of this radioisotope and the relative lack of knowledge of the dose distributions, three-dimensional dose maps of two concave applicators were calculated by means of Monte Carlo simulation. MATERIALS AND METHODS: Simulations of small CCA and CCB concave applicators manufactured by Bebig were performed using the Monte Carlo code PENELOPE, which allows the description of the structure (geometry and materials) of the applicator in detail. Electrons are emitted from the 106Ru nuclei isotropically, with initial energy randomly sampled from the corresponding Fermi spectra and with initial positions uniformly distributed on the radioactive layer. Primary electrons, as well as the produced delta-rays, are assumed to be absorbed in the medium when they slow down to an energy of 70 keV. Bremsstrahlung photons with energies larger than 7 keV are also simulated. The simulation code has been run on a 166 MHz PENTIUM PC. RESULTS: Three-dimensional dose distributions produced by the CCA and CCB applicators in a water sphere, concentric with the applicator, were evaluated. To minimize the magnitude of statistical uncertainties, advantage has been taken of the cylindrical symmetry of the problem. The relative depth-dose (along the symmetry axis of the applicator) was also evaluated from the applicator surface up to distances larger than I cm, with statistical uncertainties of a few percent. Results compare well with data supplied by the manufacturer. CONCLUSIONS: We have performed accurate Monte Carlo calculations of three-dimensional dose distributions from CCA and CCB 106Ru applicators. The results, presented in the form of two-dimensional maps, depth-dose distributions along the symmetry axis and lateral dose profiles, provide a detailed description of the dose delivered in treatments of choroidal melanoma.


Assuntos
Braquiterapia/instrumentação , Neoplasias da Coroide/radioterapia , Melanoma/radioterapia , Método de Monte Carlo , Radioisótopos de Rutênio/uso terapêutico , Simulação por Computador , Humanos , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA