Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Infrared Millim Terahertz Waves ; 42: 547-556, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34290840

RESUMO

The effect of reflection is studied experimentally and theoretically on a high-power 110 GHz gyrotron operating in the TE22,6 mode in 3 µs pulses at 96 kV, 40 A. The experimental setup allows variation of the reflected power from 0 to 33 % over a range of gyrotron operating conditions. The phase of the reflection is varied by translating the reflector along the axis. Operating at a higher efficiency point, at 4:40 T with 940 kW of output power, reflected power exceeding 11% causes a switch from operation in the TE22,6 to simultaneous operation in the TE22,6 and TE21,6 modes with a large decrease of the total gyrotron output power. This switching effect is in good agreement with simulations using the MAGY code. Operating at a more stable point, 4:44 T with 580 kW of output power, when the reflection is increased, the output power remains in the TE22,6 mode but it decreases monotonically with increasing reflection, dropping to 200 kW at 33% reflection. Furthermore, at a reflection above 22%, a power modulation at 25 to 30 MHz is observed, independent of the phase of the reflected wave. Such a modulated signal may be useful in spectroscopic and other applications.

3.
Phys Rev Lett ; 123(17): 175001, 2019 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-31702277

RESUMO

We report experimental measurements of the threshold for multipactor discharges on dielectric surfaces at 110 GHz. Multipactor was studied in two geometries: electric field polarized parallel to or perpendicular to the sample surface. Measured multipactor thresholds ranged from 15 to 34 MV/m, more than 10 times higher than those found at conventional microwave frequencies. Measured thresholds were compared with prior data at lower frequencies, showing agreement with theoretical predictions that thresholds increase linearly with frequency. Measurements of the rf power dissipated in the multipactor show low dissipation (≤1%) for the parallel electric field case, but very strong dissipation for the perpendicular case, also in agreement with theoretical predictions. The agreement between experiment and theory over a wide range of frequencies provides a strong basis for the understanding of dielectric multipactor discharges.

4.
Phys Rev Lett ; 123(24): 244801, 2019 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-31922865

RESUMO

This Letter reports the successful experimental demonstration of amplification of subterahertz radiation in a klystron with photonic crystal cavities. The klystron has six cavities, with each cavity having a series of oversized photonic crystal cells made up of a 5×3 array of square posts. The center post is removed from each cell to form a highly oversized (0.8 mm∼λ/4) beam tunnel, with power coupling from cell to cell through the tunnel. The pulsed electron beam is operated at 23.5 kV, 330 mA in a 0.5 T solenoidal field. At 93.7 GHz, a small-signal gain of 26 dB and a saturated output power of 30 W are obtained. Experimental results are in very good agreement with the predictions of a particle-in-cell code. The successful achievement of high gain operation of a photonic crystal klystron amplifier is promising for the future extension of klystron operation well into the terahertz frequency region.

5.
Phys Rev Lett ; 117(23): 237701, 2016 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-27982613

RESUMO

An electron beam passing through a metamaterial structure is predicted to generate reversed Cherenkov radiation, an unusual and potentially very useful property. We present an experimental test of this phenomenon using an intense electron beam passing through a metamaterial loaded waveguide. Power levels of up to 5 MW are observed in backward wave modes at a frequency of 2.40 GHz using a one microsecond pulsed electron beam of 490 keV, 84 A in a 400 G magnetic field. Contrary to expectations, the output power is not generated in the Cherenkov mode. Instead, the presence of the magnetic field, which is required to transport the electron beam, induces a Cherenkov-cyclotron (or anomalous Doppler) instability at a frequency equal to the Cherenkov frequency minus the cyclotron frequency. Nonlinear simulations indicate that the Cherenkov-cyclotron mode should dominate over the Cherenkov instability at a lower magnetic field where the highest output power is obtained.

6.
J Infrared Millim Terahertz Waves ; 37(1): 100-110, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27053963

RESUMO

Simple analytical formulae are presented for the design of linear tapers with very low mode conversion loss in overmoded corrugated waveguides. For tapers from waveguide radius a2 to a1, with a1 < a2, the optimal length of the taper is 3.198a1a2/λ. Here, λ is the wavelength of radiation. The fractional loss of the HE11 mode in an optimized taper is [Formula: see text]. These formulae are accurate when a2 ≲ 2a1. Slightly more complex formulae, accurate for a2 ≤ 4a1, are also presented in this paper. The loss in an overmoded corrugated linear taper is less than 1 % when a2 ≤ 2.12a1 and less than 0.1 % when a2 ≤ 1.53a1. The present analytic results have been benchmarked against a rigorous mode matching code and have been found to be very accurate. The results for linear tapers are compared with the analogous expressions for parabolic tapers. Parabolic tapers may provide lower loss, but linear tapers with moderate values of a2/a1 may be attractive because of their simplicity of fabrication.

7.
Phys Rev Lett ; 111(23): 235101, 2013 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-24476286

RESUMO

We report the experimental demonstration of a gyrotron traveling-wave-tube amplifier at 250 GHz that uses a photonic band gap (PBG) interaction circuit. The gyrotron amplifier achieved a peak small signal gain of 38 dB and 45 W output power at 247.7 GHz with an instantaneous -3 dB bandwidth of 0.4 GHz. The amplifier can be tuned for operation from 245-256 GHz. The widest instantaneous -3 dB bandwidth of 4.5 GHz centered at 253.25 GHz was observed with a gain of 24 dB. The PBG circuit provides stability from oscillations by supporting the propagation of transverse electric (TE) modes in a narrow range of frequencies, allowing for the confinement of the operating TE03-like mode while rejecting the excitation of oscillations at nearby frequencies. This experiment achieved the highest frequency of operation for a gyrotron amplifier; at present, there are no other amplifiers in this frequency range that are capable of producing either high gain or high output power. This result represents the highest gain observed above 94 GHz and the highest output power achieved above 140 GHz by any conventional-voltage vacuum electron device based amplifier.


Assuntos
Ciclotrons/instrumentação , Modelos Teóricos , Óptica e Fotônica/instrumentação , Óptica e Fotônica/métodos
9.
Phys Rev Lett ; 105(13): 135101, 2010 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-21230783

RESUMO

An experimental study of picosecond pulse amplification in a gyrotron-traveling wave tube (gyro-TWT) has been carried out. The gyro-TWT operates with 30 dB of small signal gain near 140 GHz in the HE06 mode of a confocal waveguide. Picosecond pulses show broadening and transit time delay due to two distinct effects: the frequency dependence of the group velocity near cutoff and gain narrowing by the finite gain bandwidth of 1.2 GHz. Experimental results taken over a wide range of parameters show good agreement with a theoretical model in the small signal gain regime. These results show that in order to limit the pulse broadening effect in gyrotron amplifiers, it is crucial to both choose an operating frequency at least several percent above the cutoff of the waveguide circuit and operate at the center of the gain spectrum with sufficient gain bandwidth.


Assuntos
Amplificadores Eletrônicos , Ciclotrons , Processamento de Sinais Assistido por Computador/instrumentação , Micro-Ondas
10.
Int J Infrared Millimeter Waves ; 29(11): 1011-1018, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19081774

RESUMO

We report the measurement of small losses in transmission line (TL) components intended for high-power millimeter-wave applications. Measurements were made using two different low-power techniques: a coherent technique using a vector network analyzer (VNA) and an incoherent technique using a radiometer. The measured loss in a 140 GHz 12.7 mm diameter TL system, consisting of 1.7 m of circular corrugated waveguide and three miter bends, is dominated by the miter bend loss. The measured loss was 0.3±0.1 dB per miter bend using a VNA; and 0.22±0.1 dB per miter bend using a radiometer. Good agreement between the two measurement techniques implies that both are useful for measuring small losses. To verify the methodology, the VNA technique was employed to measure the extremely small transmission loss in a 170 GHz ITER prototype TL system consisting of three lengths of 1 m, 63.5 mm diameter, circular corrugated waveguide and two miter bends. The measured loss of 0.05±0.02 dB per miter bend may be compared with the theoretical loss of 0.027 dB per miter bend. These results suggest that low-power testing of TL losses, utilizing a small, simple TL system and a VNA, is a reliable method for evaluating performance of low-loss millimeter-wave TL components intended for use in high-power applications.

11.
Phys Rev Lett ; 100(3): 035003, 2008 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-18232990

RESUMO

We report the observation of two-dimensional plasma filamentary arrays with more than 100 elements generated during breakdown of air at atmospheric pressure by a focused Gaussian beam from a 1.5-MW, 110-GHz gyrotron operating in 3-micros pulses. Each element is a plasma filament elongated in the electric field direction and regularly spaced about one-quarter wavelength apart in the plane perpendicular to the electric field. The development of the array is explained as a result of diffraction of the beam around the filaments, leading to the sequential generation of high intensity spots, at which new filaments are created, about a quarter wavelength upstream from each existing filament. Electromagnetic wave simulations corroborate this explanation and show very good correlation to the observed pattern of filaments.

12.
Appl Magn Reson ; 34(3-4): 237-263, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19194532

RESUMO

Dynamic nuclear polarization (DNP) results in a substantial nuclear polarization enhancement through a transfer of the magnetization from electrons to nuclei. Recent years have seen considerable progress in the development of DNP experiments directed towards enhancing sensitivity in biological nuclear magnetic resonance (NMR). This review covers the applications, hardware, polarizing agents, and theoretical descriptions that were developed at the Francis Bitter Magnet Laboratory at Massachusetts Institute of Technology for high-field DNP experiments. In frozen dielectrics, the enhanced nuclear polarization developed in the vicinity of the polarizing agent can be efficiently dispersed to the bulk of the sample via (1)H spin diffusion. This strategy has been proven effective in polarizing biologically interesting systems, such as nanocrystalline peptides and membrane proteins, without leading to paramagnetic broadening of the NMR signals. Gyrotrons have been used as a source of high-power (5-10 W) microwaves up to 460 GHz as required for the DNP experiments. Other hardware has also been developed allowing in situ microwave irradiation integrated with cryogenic magic-angle-spinning solid-state NMR. Advances in the quantum mechanical treatment are successful in describing the mechanism by which new biradical polarizing agents yield larger enhancements at higher magnetic fields. Finally, pulsed methods and solution experiments should play a prominent role in the future of DNP.

14.
Opt Lett ; 31(13): 2051-3, 2006 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-16770429

RESUMO

The effect of spatial dispersion on the electromagnetic properties of a metamaterial consisting of a three-dimensional mesh of crossing metallic wires is reported. The effective dielectric permittivity tensor epsilon(ij)(omega, k) of the wire mesh is calculated in the limit of small wavenumbers. The procedure for extracting the spatial dispersion from the omega versus k dependence for electromagnetic waves propagating in the bulk of the metamaterial is developed. These propagating modes are identified as similar to the longitudinal (plasmon) and transverse (photon) waves in a plasma. Spatial dispersion is found to have the most dramatic effect on the surface waves that exist at the wire mesh-vacuum interface.

15.
Phys Rev Lett ; 94(5): 054803, 2005 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-15783652

RESUMO

We report the observation of enhanced coherent Smith-Purcell radiation (SPR) at terahertz (THz) frequencies from a train of picosecond bunches of 15 MeV electrons passing above a grating. SPR is more intense than other sources, such as transition radiation, by a factor of Ng, the number of grating periods. For electron bunches that are short compared with the radiation wavelength, coherent emission occurs, enhanced by a factor of Ne, the number of electrons in the bunch. The electron beam consists of a train of Nb bunches, giving an energy density spectrum restricted to harmonics of the 17 GHz bunch train frequency, with an increased energy density at these frequencies by a factor of Nb. We report the first observation of SPR displaying all three of these enhancements, NgNeNb. This powerful SPR THz radiation can be detected with a high signal to noise ratio by a heterodyne receiver.

16.
Phys Rev Lett ; 90(25 Pt 1): 258302, 2003 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-12857176

RESUMO

We present the design and experimental results of a novel quasioptical gyrotron traveling-wave tube (gyro-TWT) amplifier at 140 GHz. The gyro-TWT produced up to 30 kW of peak power in 2 micros pulsed operation at 6 Hz achieving a peak gain of 29 dB, a peak efficiency of 12%, and a bandwidth of 2.3 GHz. The device was operated in a very higher-order mode of an open quasioptical interaction structure, namely, a confocal waveguide. The diffraction loss from the open sidewalls of the confocal waveguide was used to suppress mode competition in this highly overmoded circuit resulting in a stable single-mode operation. The experiment achieved record high power levels at 140 GHz for a gyro-TWT. These experiments demonstrate the effectiveness of using overmoded quasioptical waveguide interaction structures for generating high power in the millimeter and submillimeter wave bands with a gyro-TWT.

17.
J Magn Reson ; 160(2): 85-90, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12615147

RESUMO

In this communication, we report enhancements of nuclear spin polarization by dynamic nuclear polarization (DNP) in static and spinning solids at a magnetic field strength of 9T (250 GHz for g=2 electrons, 380 MHz for 1H). In these experiments, 1H enhancements of up to 170+/-50 have been observed in 1-13C-glycine dispersed in a 60:40 glycerol/water matrix at temperatures of 20K; in addition, we have observed significant enhancements in 15N spectra of unoriented pf1-bacteriophage. Finally, enhancements of approximately 17 have been obtained in two-dimensional 13C-13C chemical shift correlation spectra of the amino acid U-13C, 15N-proline during magic angle spinning (MAS), demonstrating the stability of the DNP experiment for sustained acquisition and for quantitative experiments incorporating dipolar recoupling. In all cases, we have exploited the thermal mixing DNP mechanism with the nitroxide radical 4-amino-TEMPO as the paramagnetic dopant. These are the highest frequency DNP experiments performed to date and indicate that significant signal enhancements can be realized using the thermal mixing mechanism even at elevated magnetic fields. In large measure, this is due to the high microwave power output of the 250 GHz gyrotron oscillator used in these experiments.


Assuntos
Isótopos de Carbono/química , Espectroscopia de Ressonância Magnética , Óxido Nítrico/química , Bacteriófagos , Humanos , Micro-Ondas
18.
J Anat ; 200(5): 431-8, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12090389

RESUMO

Using magnetic resonance imaging (MRI), the internal neural and craniofacial malformations of a cyclopic fetus are described. External facial features were characterized by a tubular proboscis situated above a single eye slit. The brain was recognized as 'pancake' type alobar holoprosencephaly (a condition where the undifferentiated telencephalon partially surrounds a monoventricle). Displacement of some bones that normally contribute to the orbit could be clearly discerned. Absence of neural structures (e.g. falx cerebri, corpus callosum) and missing components of the ethmoid bone indicated a midline deficit. This correlates with proposed theories of cyclopic embryopathy, which suggest that the prechordal plate and the neural crest cells are affected during the third week of gestation in cyclopia.


Assuntos
Anormalidades Múltiplas/patologia , Anormalidades Craniofaciais/patologia , Anormalidades do Olho/patologia , Cabeça/patologia , Imageamento por Ressonância Magnética , Humanos , Recém-Nascido , Masculino
19.
Phys Rev Lett ; 86(24): 5628-31, 2001 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-11415318

RESUMO

We report the design and experimental demonstration of a gyrotron oscillator using a photonic-band-gap (PBG) structure to eliminate mode competition in a highly overmoded resonator. The PBG cavity supports a TE(041)-like mode at 140 GHz and is designed to have no competing modes over a minimum frequency range delta omega/omega of 30% about the design mode. Experimental operation of a PBG gyrotron at 68 kV and 5 A produced 25 kW of peak power in the design mode. No other modes were observed over the full predicted operating range about the design mode. PBG cavities show great promise for applications in vacuum electron devices in the millimeter- and submillimeter-wave bands.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...