Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomimetics (Basel) ; 8(5)2023 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-37754159

RESUMO

The structure, phase composition, corrosion and mechanical properties, as well as aspects of biocompatibility in vitro and in vivo, of a Zn-1%Mg-0.1%Dy alloy after equal-channel angular pressing (ECAP) were studied. The structure refinement after ECAP leads to the formation of elongated α-Zn grains with a width of ~10 µm and of Mg- and Dy-containing phases. In addition, X-ray diffraction analysis demonstrated that ECAP resulted in the formation of the basal texture in the alloy. These changes in the microstructure and texture lead to an increase in ultimate tensile strength up to 262 ± 7 MPa and ductility up to 5.7 ± 0.2%. ECAP slows down the degradation process, apparently due to the formation of a more homogeneous microstructure. It was found that the alloy degradation rate in vivo after subcutaneous implantation in mice is significantly lower than in vitro ones. ECAP does not impair biocompatibility in vitro and in vivo of the Zn-1%Mg-0.1%Dy alloy. No signs of suppuration, allergic reactions, the formation of visible seals or skin ulcerations were observed after implantation of the alloy. This may indicate the absence of an acute reaction of the animal body to the Zn-1%Mg-0.1%Dy alloy in both states.

2.
Materials (Basel) ; 15(24)2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36556879

RESUMO

The effect of high-pressure torsion (HPT) on the microstructure, phase composition, mechanical characteristics, degradation rate, and bioactive properties of the Zn-1%Mg alloy is studied. An ultrafine-grained (UFG) structure with an average grain size of α-Zn equal to 890 ± 26 nm and grains and subgrains of the Mg2Zn11 and MgZn2 phases with a size of 50-100 nm are formed after HPT. This UFG structure leads to an increase in the ultimate tensile strength of the alloy by ~3 times with an increase in elongation to 6.3 ± 3.3% due to the formation of a basal texture. The study of corrosion resistance did not show a significant effect of HPT on the degradation rate of the alloy. In addition, no significant changes in the bioactivity of the alloy after HPT: hemolysis, cellular colonization and Escherichia coli growth inhibition.

3.
Materials (Basel) ; 12(23)2019 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-31766395

RESUMO

The effect of equal-channel angular pressing (ECAP) on the microstructure, texture, mechanical properties, corrosion resistance and cytotoxicity of two magnesium-silver alloys, Mg-2.0%Ag and Mg-4.0%Ag, was studied. Their average grain size was found to be reduced to 3.2 ± 1.4 µm and 2.8 ± 1.3 µm, respectively. Despite the substantial grain refinement, a drop in the strength characteristics of the alloys was observed, which can be attributed to the formation of inclined basal texture. On a positive side, an increase in tensile ductility to ~34% for Mg-2.0%Ag and ~27% for Mg-4.0%Ag was observed. This effect can be associated with the activity of basal and prismatic slip induced by ECAP. One of the ECAP regimes tested gave rise to a drop in the corrosion resistance of both alloys. An interesting observation was a cytotoxic effect both alloys had on tumor cells in vitro. This effect was accompanied with the release of lactate dehydrogenase, an increase in oxidative stress, coupled with the induction of NO-ions and an increase in the content of such markers of apoptosis as Annexin V and Caspase 3/7. Differences in the chemical composition and the processing history-dependent microstructure of the alloys did not have any significant effect on the magnitude of their antiproliferative effect.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...