Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Vasc Surg ; 79(5): 1005-1012, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38157994

RESUMO

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) has been used extensively in the management of thoracic aortic diseases. Numerous efforts have been made to enhance clinical outcomes through the use of stent grafts. This study aimed to investigate the effectiveness and safety of physician-manufactured partial micropore stent grafts (PSMGs) in TEVAR. METHODS: Between December 2017 and June 2022, data were collected from 56 patients who underwent TEVAR using physician-manufactured PSMGs. The evaluation encompassed technical success, perioperative and follow-up morbidity and mortality, stroke incidence, and branch artery patency. RESULTS: In this investigation, 56 patients received treatment with physician-manufactured PSMGs. Of these patients, 46 were male, with a mean age of 62.1 ± 11.2 years. Aortic pathologies comprised aortic dissection (n = 31 [55.4%]), aortic aneurysms (n = 10 [17.9%]), penetrating aortic ulcer (n = 8 [14.3%]), and intramural hematoma (n = 7 [12.5%]). During a median follow-up of 18 months (interquartile range, 13-25 months), the stroke rate, supra-aortic branch patency rate, and endoleak rate were 0%, 100%, and 7.1%, respectively. There were no occurrences of all-cause mortality, stroke, or the necessity for open conversion. CONCLUSIONS: TEVAR with physician-manufactured PSMGs is a viable alternative for addressing aortic arch pathologies in proficient medical centers. The approach demonstrates favorable branch patency, a low complication rate, and minimal postoperative mortality.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Fatores de Tempo , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia
2.
Quant Imaging Med Surg ; 13(9): 5986-5995, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37711789

RESUMO

Background: Iliac vein compression syndrome (IVCS) is an underlying cause of varicose vein (VV) recurrence after venous surgery. However, the management of recurrent varicose veins (RVVs) combined with IVCS has rarely been reported. This study aimed to investigate the outcomes of a one-stop procedure to correct outflow obstruction and superficial reflux for patients with RVVs and IVCS. Methods: A retrospective analysis was conducted of 102 consecutive patients diagnosed with RVVs. Computed tomography venography (CTV) was performed to confirm IVCS. The cases were divided into 2 groups: the IRVVs group, including patients with RVVs and IVCS (n=48), and the RVVs group, including patients with RVVs only (n=54). The characteristics, vein reflux, and clinical, etiological, anatomical, and pathophysiological (CEAP) distribution were investigated. Then, the IRVVs group patients who underwent endovenous laser ablation (EVLA) (n=39) were divided into a further 2 groups: the EVLA + S group (n=19), who received EVLA and stenting of iliac vein, and the EVLA group (n=20), who received EVLA treatment alone. The great/small saphenous vein (GSV/SSV) trunk occlusion, VV recurrence, visual analogue scale (VAS), and venous clinical severity score (VCSS) were investigated. Results: The prevalence rate of femoral vein reflux was 81.2% in IRVVs group and 50% in RVVs group (P<0.05). In the IRVVs group, 72.9% of patients manifested as CEAP clinical class >3, which was higher than that in RVVs group (48.1%) (P<0.05). The 12-month GSV/SSV occlusion rate in the EVLA + S and EVLA groups were 94.7% and 90.0%, respectively. Totals of 9 patients in EVLA + S group and 6 patients in EVLA group had active venous ulcers, and the ulcer healing time in EVLA + S group was significantly shorter (27.22±7.12 vs. 46.67±9.83 days, P<0.05). The reductions in the VAS and VCSS values between baseline, 1 month, and 12 months in the EVLA + S group were more obvious than those in EVLA group (P<0.05). Conclusions: The one-stop combination treatment of iliac venous stenting and EVLA in patients with RVVs and IVCS is safe and effective and provides prominent symptom relief, improved quality of life, and a more satisfactory ulcer healing than EVLA alone.

3.
Semin Dial ; 36(5): 357, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37548053

RESUMO

We comment on the recently published to investigate hemodynamic changes in central venous stenosis patients before and after stent placement. Through the evidence, we believe that the boundary conditions in computational models and simulations of this study are incorrect in three points.


Assuntos
Hidrodinâmica , Diálise Renal , Humanos , Constrição Patológica , Diálise Renal/efeitos adversos , Stents , Hemodinâmica , Simulação por Computador
4.
Clin Exp Hypertens ; 45(1): 2224940, 2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-37326510

RESUMO

BACKGROUND AND AIMS: Percutaneous mechanical thrombectomy (PMT) along with postoperative thrombolysis (POT) has been the standard treatment for acute iliofemoral deep venous thrombosis (IFDVT). However, commonly used catheter directed thrombolysis (CDT) approaches for POT carry certain disadvantages, including the need for a sheath, inferior comfortability, and catheter-related complications. Therefore, we propose a new simplified method of POT using a central venous catheter (CVC). METHODS: The retrospective study analyzed patients with IFDVT who underwent POT using CVC from January 2020 to August 2021. The treatment modalities included filter placement, thrombus removal, iliac vein obstruction release, postoperative CVC thrombolysis, filter retrieval, and adequate full course anticoagulation. RESULTS: A total of 39 patients were included in this retrospective study. All patients underwent PMT surgery with a procedure success rate of 100%. In the post-PMT CVC thrombolysis, the puncture sites were located in the below-knee vein, including 58.97% in the peroneal vein. The mean duration of CVC-directed thrombolysis was 3.69 ± 1.08 days, and the total urokinase dose was 2.27 ± 0.71 MIU. A total of 37 patients (94.87%) had successful thrombolysis with a length of hospital stay of 5.82 ± 2.21 days. During CVC-directed thrombolysis, only four minor bleeding complications occurred, two of which were indwelling catheter-related. During the 12-month follow-up period, the patency rate and post-thrombotic syndrome incidences were 97.44% and 2.56%, respectively. CONCLUSION: Thrombolysis through a CVC is a feasible, safe, and effective POT method, and could be an alternative to the conventional CDT approach for patients with IFDVT.


Assuntos
Cateteres Venosos Centrais , Trombose Venosa , Humanos , Terapia Trombolítica/métodos , Cateteres Venosos Centrais/efeitos adversos , Estudos Retrospectivos , Veia Femoral/cirurgia , Trombose Venosa/tratamento farmacológico , Trombose Venosa/etiologia , Trombose Venosa/cirurgia , Resultado do Tratamento , Fibrinolíticos/uso terapêutico
5.
Eur J Radiol ; 161: 110720, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36774671

RESUMO

OBJECTIVE: This study aimed to verify the efficacy and safety of the treatment for patients diagnosed with DeBakey type I and type III thoracic aortic dissections using a partial micropore stent graft. METHODS: We conducted a retrospective analysis of 32 patients who suffered from thoracic aortic dissection and underwent endovascular repair using a partial micropore stent graft at our center between December 2018 and January 2020. RESULTS: The technical success rate for 32 patients was 100 %, while no 30-day mortality was observed. In the 30 patients finished follow-ups, 30 (mean: 1 per patient) micropore stents were implanted, while the openings of 90 (mean: 3 per patient) aortic arch branches were covered by the stents. After more than 12 months follow-up, 26 (86.7 %) of the 30 patients presented with a complete thrombosis in the false lumen, and 4 (13.3 %) patients presented with a partial thrombosis in the false lumen. All 90 aortic arch branches were patent. No aortic arch branch artery stenosis or occlusion was observed. CONCLUSIONS: The outcomes obtained during 12 months of follow-up suggested that performing endovascular repair for thoracic aortic dissection patients with a partial micropore stent graft is safe and effective, maintaining the patency of aortic arch branch vessels.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Seguimentos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Aorta Torácica , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese , Stents/efeitos adversos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia
6.
Front Oncol ; 12: 881487, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36106106

RESUMO

The first-line anticancer agent oxaliplatin (OXL) is the preferred drug for treating colorectal cancer (CRC); however, the development of drug resistance is common in patients treated with OXL, which considerably reduces the efficacy of OXL-based regimens. By performing genome-wide CRISPR/Cas9 library knockdown screening, we found that mitochondrial elongation factor 2 (MIEF2) was among the top candidate genes. The OXL-resistant cell lines and organoids developed in the present study showed stable but low expression of MIEF2. Reduced MIEF2 expression may enhance CRC resistance to OXL by reducing mitochondrial stability and inhibiting apoptosis by decreasing cytochrome C release. In conclusion, among the different biomarkers of OXL resistance in CRC, MIEF2 may serve as a specific biomarker of OXL responsiveness and a potential target for the development of therapies to improve chemotherapeutic effectiveness.

7.
Front Physiol ; 13: 926508, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35874515

RESUMO

Purpose: Abdominal aortic aneurysm (AAA) is a severe cardiovascular disease that often results in high mortality due to sudden rupture. This paper aims to explore potential molecular mechanisms and effective targeted therapies to prevent and delay AAA rupture. Methods: We downloaded two microarray datasets (GSE98278 and GSE17901) from the Gene Expression Omnibus (GEO) database. Differential analysis and single-sample gene set enrichment analysis (ssGSEA) of hypoxia scores were performed on 48 AAA patients in GSE98278. We identified hypoxia- and ruptured AAA-related gene modules using weighted gene coexpression network analysis (WGCNA). Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) analyses were performed using the R package clusterProfiler. For candidate genes, validation was conducted on the mouse dataset GSE17901. Finally, we predicted drug candidates associated with the hub genes using the HERB Chinese medicine database. Results: Eighty-two differentially expressed genes were screened in the ruptured and stable groups; 103 differentially expressed genes were identified between the high- and low-hypoxia groups; and WGCNA identified 58 differentially expressed genes. Finally, nine candidate genes were screened, including two hub genes (MEDAG and SERPINE1). We identified pathways such as cytokine-cytokine receptor interaction and T-helper 1-type immune response involved in AAA hypoxia and rupture. We predicted 93 traditional Chinese medicines (TCMs) associated with MEDAG and SERPINE1. Conclusion: We identified the hypoxic molecules MEDAG and SERPINE1 associated with AAA rupture. Our study provides an additional direction for the association between hypoxia and AAA rupture.

8.
Cardiovasc Intervent Radiol ; 45(6): 752-760, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35415808

RESUMO

PURPOSE: To discuss the risk factors for abdominal aortic aneurysm rupture based on geometric and hemodynamic parameters. METHODS: We retrospectively reviewed the clinical data of those who were diagnosed with an abdominal aortic aneurysm by computed tomography angiography at our hospital between October 2019 and December 2020. Thirty-five patients were included in the ruptured group (13 patients) and the unruptured group (22 patients). We analyzed the differences and correlations of anatomical factors and hemodynamic parameters between the two groups using computational fluid dynamics based on computed tomography angiography. RESULTS: There were significant differences in the maximum diameter [(79.847 ± 10.067) mm vs. (52.320 ± 14.682) mm, P < 0.001], curvature [(0.139 ± 0.050) vs. 0.080 (0.123 - 0.068), P = 0.021], and wall shear stress at the site of maximal blood flow impact [0.549(0.839 - 0.492) Pa vs. (1.378 ± 0.255) Pa, P < 0.001] between the ruptured and unruptured groups, respectively. And in the ruptured group, wall shear stress at the rupture site was significantly different from that at the site of maximal blood flow impact [0.025 (0.049 - 0.018) Pa vs. 0.549 (0.839 - 0.492) Pa, P = 0.001]. Then, the maximum diameter and curvature were associated with rupture (maximum diameter: OR: 1.095, P = 0.003; curvature: OR: 1.142E + 10, P = 0.012). Most importantly, curvature is negatively correlated with wall shear stress (r = - 0.366, P = 0.033). CONCLUSIONS: Both curvature and wall shear stress can evaluate the rupture risk of aneurysm. Also, curvature can be used as the geometric substitution of wall shear stress.


Assuntos
Aneurisma Roto , Aneurisma da Aorta Abdominal , Ruptura Aórtica , Aneurisma Intracraniano , Aneurisma Roto/complicações , Aneurisma da Aorta Abdominal/complicações , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Hemodinâmica/fisiologia , Humanos , Hidrodinâmica , Aneurisma Intracraniano/complicações , Estudos Retrospectivos , Fatores de Risco , Estresse Mecânico
9.
Med Sci Monit ; 28: e935006, 2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35286296

RESUMO

BACKGROUND Ruptured abdominal aortic aneurysms have been a topic of common global interest for the past 20 years, with a steadily increasing number of publications. The purpose of this study was to explore the research themes and the current status of the last 10 years through a bibliometric analysis of the publications in this field. MATERIAL AND METHODS We performed a literature search for ruptured abdominal aortic aneurysms using the Web of Science Core Collection on November 14, 2021 and performed a bibliometric analysis and visualization of the results of the publications using the R-Bibliometrix package and VOSviewer software. RESULTS From 2011 to 2020, 2381 publications were retrieved, including 2073 articles and 308 reviews. The United States had the highest number of publications and has made a large contribution to the field. Jonathan Golledge is an important researcher with the highest number of publications. Journal of Vascular Surgery is ranked first in terms of the number of publications and local citations. Mortality and outcomes, repair treatment, and risk factors are the 3 main focuses in the field, followed by intraluminal thrombus and molecular expression. CONCLUSIONS Our bibliometric analysis suggests mainstream research is focused on clinical studies related to the surgical approach and its prognosis and on pathological mechanisms and hemodynamic studies related to risk factors for abdominal aortic aneurysms rupture. There are many other opportunities for future research in the clinical joint basis of abdominal aortic aneurysms rupture.


Assuntos
Aneurisma Roto/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Bibliometria , Procedimentos Cirúrgicos Vasculares/estatística & dados numéricos , Aneurisma Roto/epidemiologia , Aneurisma da Aorta Abdominal/epidemiologia , Saúde Global , Humanos , Incidência , Fatores de Risco
10.
Medicine (Baltimore) ; 100(39): e27306, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34596128

RESUMO

BACKGROUND: The purpose of this study was to compare the hemodynamic parameters of symptomatic and asymptomatic abdominal aortic aneurysms (AAAs) to explore the risk factors for AAA rupture. METHODS: We conducted a retrospective analysis of 26 patients with symptomatic small AAAs and 60 patients with asymptomatic small AAAs. Computational fluid dynamics methods were used to compare hemodynamic characteristics between the symptomatic and asymptomatic groups and to evaluate risk factors for the occurrence of symptomatic AAAs. RESULTS: The maximum diameters in the symptomatic and asymptomatic groups were 49.7 ±â€Š4.94 mm and 48.4 ±â€Š4.55 mm, respectively. Wall shear stress values at turbulent flow regions in the symptomatic and asymptomatic groups were 0.0098 ±â€Š0.0084 Pa versus 0.0174 ±â€Š0.0068 Pa, respectively. Shear stress values at the site with maximal blood flow impact force in the symptomatic and asymptomatic groups were 1.13 ±â€Š0.466 Pa and 2.04 ±â€Š0.42 Pa, respectively. The areas of the intra-luminal thrombus in the section with the maximum diameter in the symptomatic and asymptomatic groups were 952.19 ±â€Š413.53 mm2 versus 646.63 ±â€Š296.88 mm2, respectively. CONCLUSION: The wall shear stress in the symptomatic group was lower than that in the asymptomatic group.


Assuntos
Aneurisma da Aorta Abdominal/fisiopatologia , Hemodinâmica/fisiologia , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Comorbidade , Feminino , Humanos , Hidrodinâmica , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
11.
ACS Appl Mater Interfaces ; 13(30): 35248-35265, 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-34284582

RESUMO

The sonic hedgehog (SHH) signaling pathway exhibits aberrant activation in triple-negative breast cancer (TNBC), wherein it regulates several malignant phenotypes related to tumor metastasis. GANT61, an inhibitor of the SHH signaling pathway, may offer promise when administered in combination with conventional chemotherapy to treat metastatic TNBC. However, poor bioavailability and substantial off-target toxicity limit its clinical application. To address these limitations, we designed a peptide-functionalized dual-targeting delivery system encapsulating paclitaxel and GANT61 in tLyP-1 peptide-modified reconstituted high-density lipoprotein nanoparticle (tLyP-1-rHDL-PTX/GANT61 NP) for metastatic TNBC treatment. The apolipoprotein A-1 and tLyP-1 peptide modified on the surface of nanoparticles enable the delivery system to target tumor cells by binding to the overexpressed scavenger receptor B type I and neuropilin-1 receptor. Moreover, the tLyP-1 peptide also enables the deep tumor penetration of nanoparticles further facilitating paclitaxel and GANT61 delivery. Increased cellular uptake of the nanoparticles was observed in both MDA-MB-231, BT-549 tumor cells, and their 3D tumor spheroids. A series of in vitro experiments reveal that GANT61 was able to suppress key metastasis-related tumor cell activities including angiogenesis, migration, invasion, and stemness. Owing to more effective drug administration, the metastasis suppression efficiency of GANT61 was significantly enhanced by the dual-targeting tLyP-1-rHDL delivery system. Meanwhile, the codelivery of paclitaxel and GANT61 by dual-targeting tLyP-1-rHDL nanoparticles demonstrated superior efficiency of disrupting proliferation and inducing apoptosis in tumor cells compared with drug solutions. In a spontaneous metastasis breast cancer NCG mice model, the tLyP-1-rHDL-PTX/GANT61 nanoparticles exhibited highly tumor-specific distribution and result in significant inhibition of the primary tumor growth and dramatic reduction of lung metastasis without obvious side effects. The present work suggests that a combination of the SHH signaling pathway suppression and chemotherapy assisted by peptide-functionalized targeting tLyP-1-rHDL nanoparticles may provide a promising strategy for metastatic TNBC treatment.


Assuntos
Antineoplásicos Fitogênicos/uso terapêutico , Portadores de Fármacos/química , Lipoproteínas HDL/química , Nanopartículas/química , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Animais , Apoptose/efeitos dos fármacos , Linhagem Celular Tumoral , Movimento Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Combinação de Medicamentos , Liberação Controlada de Fármacos , Feminino , Humanos , Camundongos , Paclitaxel/uso terapêutico , Piridinas/uso terapêutico , Pirimidinas/uso terapêutico , Transdução de Sinais/efeitos dos fármacos , Ensaios Antitumorais Modelo de Xenoenxerto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...