Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pediatr Transplant ; 28(1): e14585, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37489596

RESUMO

BACKGROUND: Cryptococcus neoformans is the third most common cause of invasive fungal infection in solid organ transplant (SOT) recipients. While cryptococcal infection can involve any organ, cases of myocarditis are exceedingly rare. METHODS: A retrospective chart review was completed for this case report. RESULTS: We present the case of a 21-year-old heart transplant recipient who developed disseminated cryptococcal infection with biopsy-proven cryptococcal myocarditis. CONCLUSIONS: Cryptococcal disease in SOT recipients poses diagnostic and therapeutic challenges. There are no current guidelines for the duration of cryptococcal myocarditis treatment. Repeat myocardial biopsy may play a role in guiding length of therapy.


Assuntos
Criptococose , Cryptococcus neoformans , Transplante de Coração , Miocardite , Humanos , Adulto Jovem , Adulto , Estudos Retrospectivos , Miocardite/complicações , Miocardite/diagnóstico , Criptococose/complicações , Criptococose/diagnóstico , Criptococose/tratamento farmacológico , Transplante de Coração/efeitos adversos
2.
J Intensive Care Med ; 38(12): 1099-1107, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37545322

RESUMO

Background: Despite its widespread use, there are no direct studies comparing mini-bronchoalveolar lavage (mini-BAL) to bronchoscopic bronchoalveolar lavage (BAL) for diagnosing pneumonia in ventilated patients. The aim of this study was to perform a systematic review of studies comparing ventilated patients undergoing both bronchoscopic BAL and mini-BAL, to determine the mini-BAL's diagnostic accuracy. Methods: We conducted a systematic review searching the databases PubMed (MEDLINE), EMBASE, Cochrane Library, Scopus, and clinicaltrials.gov from inception until January 2022, in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Search terms included variations on "pneumonia," "critical illness," and "mini-bronchoalveolar lavage." Article screening and data extraction were performed independently by 2 reviewers. Results: Our search yielded 4296 abstracts. This was narrowed to 6 studies in which each patient underwent both mini-BAL and bronchoscopic BAL in succession. Included patients had a mean APACHE II score of 20.02 ± 3.81 and 15.95 ± 11.46 ventilator days. The sensitivity of the mini-BAL for diagnosis of pneumonia was 0.90 (95% confidence interval [CI]: 0.778-1.000) and the specificity was 0.827 (95% CI: 0.716-0.938). Limitations included inconsistency in volume of saline instilled and heterogeneity in included patients Conclusion: This study is the first to compile data from multiple publications directly comparing the mini-BAL to bronchoscopic BAL for diagnosing pneumonia in ventilated patients. Our data demonstrate a high degree of both sensitivity and specificity of mini-BAL for the diagnosis of pneumonia in ventilated patients and indicate that mini-BAL could be considered as an acceptable alternative diagnostic study.


Assuntos
Pneumonia , Respiração Artificial , Humanos , Líquido da Lavagem Broncoalveolar , Estudos Prospectivos , Pneumonia/diagnóstico , Lavagem Broncoalveolar
3.
Int J Hyperthermia ; 39(1): 81-96, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34949138

RESUMO

Aim: Treatment of infected orthopedic implants remains a major medical challenge, involving prolonged antibiotic therapy and revision surgery, and adding a >$1 billion annual burden to the health care system in the US alone. Exposure of metallic implants to alternating magnetic fields (AMF) generates heat that can provide a noninvasive means to target biofilm adhered to the surface. In this study, an AMF system with a solenoid coil was constructed for targeting a metal plate surgically implanted in a sheep model.Methods: A tissue-mimicking phantom of the sheep leg was developed along with simulation model of phantom and the live sheep leg. This was used evaluate heating with the AMF system and to compare experimental results with numerical simulations. Comparative AMF exposures were performed/simulated in these model for feasibility of design, verification, and validation of simulations.Results: The system produced magnetic field strengths up to 12mT and achieved plate temperatures of 65-80 °C within 10-14 s. Single and intermittent AMF exposures of a tissue-mimicking phantom agreed with numerical simulations within 5 °C. Similar agreement between experimental measurements and simulations was also observed in the live sheep metal implant model. The simulations also predicted 2-3 mm of tissue damage using a CEM43 thermal dose model for 1-h AMF exposures targeting 65 °C for pulse delays of 2.5 and 5 mins.Conclusion: This study confirmed that AMF technology can be scaled up to treat implants in a large animal model with the same rates of heating and peak temperatures achieved in prior in vitro studies. Further, numerical simulations provided accurate predictions of the heating produced by AMF on metal implants and surrounding tissues, and can be used to design AMF coils for treating human prosthetic joint implants with more complex geometrical shapes.


Assuntos
Calefação , Campos Magnéticos , Animais , Estudos de Viabilidade , Temperatura Alta , Metais , Ovinos
4.
Cancers (Basel) ; 13(21)2021 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-34771713

RESUMO

Cancer in adolescents and young adults (AYAs) deserves special consideration for several reasons. AYA cancers encompass paediatric malignancies that present at an older age than expected, or early-onset of cancers that are typically observed in adults. However, disease diagnosed in the AYA population is distinct to those same cancers which are diagnosed in a paediatric or older adult setting. Worse disease-free and overall survival outcomes are observed in the AYA setting, and the incidence of AYA cancers is increasing. Knowledge of an individual's underlying cancer predisposition can influence their clinical care and may facilitate early tumour surveillance strategies and cascade testing of at-risk relatives. This information can further influence reproductive decision making. In this review we discuss the risk factors contributing to AYA breast cancer, such as heritable predisposition, environmental, and lifestyle factors. We also describe a number of risk models which incorporate genetic factors that aid clinicians in quantifying an individual's lifetime risk of disease.

5.
Educ Health (Abingdon) ; 30(3): 193-197, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29786019

RESUMO

Background: Medical errors are among the most prevalent and serious adverse events in health care. Lack of situation awareness (SA) is an important factor leading to such errors. SA can be understood using Endsley's three-tier model: level 1 is perception, level 2 is comprehension, and level 3 is projection. While there is extensive literature on the theory of SA, it is difficult to measure and quantify. The purpose of this pilot study was to measure, identify, and characterize SA in some medical objective structured clinical examination (OSCE) guides, including a 1st year National University of Ireland, Galway (NUIG) OSCE. Methods: Two independent observers analyzed two online OSCE guides and a 1st year OSCE examination using a self-developed tool. This tool was an inferential measure of SA. The guides were first qualitatively analyzed using NVivo and then quantitatively analyzed using Excel. Results: The results indicated strong internal validity and moderate inter-rater reliability. There was limited statistically significant variance between the observers. The NUIG OSCE had relatively the fewest relative observations of SA and the Geeky Medics OSCE Guide had relatively the most observations of SA. In all guides, Level 1 SA was observed more frequently than Level 2 or 3 SA. Discussion: SA is an important factor in clinical decision-making and patient safety. The challenging aspect is how to best teach and assess SA in medical education. Simulations, such as informative and/or summative OSCEs, are considered a valuable and safe way to do so. Inter-rater reliability can be improved using tool training sessions.


Assuntos
Conscientização , Competência Clínica , Cognição , Educação de Graduação em Medicina/métodos , Avaliação Educacional , Humanos , Projetos Piloto , Reprodutibilidade dos Testes , Estudantes de Medicina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...