ACS Photonics ; 11(5): 1873-1886, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38766501

RESUMO

In this paper, we demonstrate a novel optical characterization method for ultrathin semitransparent and absorbing materials through multispectral intensity and phase imaging. The method is based on a lateral-shearing interferometric microscopy (LIM) technique, where phase-shifting allows extraction of both the intensity and the phase of transmitted optical fields. To demonstrate the performance in characterizing semitransparent thin films, we fabricated and measured cupric oxide (CuO) seeded gold ultrathin metal films (UTMFs) with mass-equivalent thicknesses from 2 to 27 nm on fused silica substrates. The optical properties were modeled using multilayer thin film interference and a parametric model of their complex refractive indices. The UTMF samples were imaged in the spectral range from 475 to 750 nm using the proposed LIM technique, and the model parameters were fitted to the measured data in order to determine the respective complex refractive indices for varying thicknesses. Overall, by using the combined intensity and phase not only for imaging and quality control but also for determining the material properties, such as complex refractive indices, this technique demonstrates a high potential for the characterization of the optical properties, of (semi-) transparent thin films.

2.
Sci Adv ; 7(47): eabj2155, 2021 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-34788099

RESUMO

Quantum techniques can be used to enhance the signal-to-noise ratio in optical imaging. Leveraging the latest advances in single-photon avalanche diode array cameras and multiphoton detection techniques, here, we introduce a supersensitive phase imager, which uses space-polarization hyperentanglement to operate over a large field of view without the need of scanning operation. We show quantum-enhanced imaging of birefringent and nonbirefringent phase samples over large areas, with sensitivity improvements over equivalent classical measurements carried out with equal number of photons. The potential applicability is demonstrated by imaging a biomedical protein microarray sample. Our technology is inherently scalable to high-resolution images and represents an essential step toward practical quantum-enhanced imaging.

3.
Anal Chim Acta ; 1077: 232-242, 2019 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-31307714

RESUMO

Sepsis is a condition characterized by a severe stage of blood-infection often leading to tissue damage, organ failure and finally death. Fast diagnosis and identification of the sepsis stage (sepsis, severe sepsis or septic shock) is critical for the patient's evolution and could help in defining the most adequate treatment in order to reduce its mortality. The combined detection of several biomarkers in a timely, specific and simultaneous way could ensure a more accurate diagnosis. We have designed a new optical point-of-care (POC) device based on a phase-sensitive interferometric biosensor with a label-free microarray configuration for potential high-throughput evaluation of specific sepsis biomarkers. The sensor chip, which relies on the use of metallic nanostructures, provides versatility in terms of biofunctionalization, allowing the efficient immobilization of different kind of receptors such as antibodies or oligonucleotides. We have focused on two structurally different types of biomarkers: proteins, including C-reactive protein (CRP) and Interleukin 6 (IL6), and miRNAs, using miRNA-16 as an example. Limits of Detection (LoD) of 18 µg mL-1, 88 µg mL-1 and 1 µM (6 µg mL-1) have been respectively obtained for CRP, IL6 and miRNA-16 in individual assays, with high accuracy and reproducibility. The multiplexing capabilities have also been assessed with the simultaneous analysis of both protein biomarkers.


Assuntos
Proteína C-Reativa/análise , Interleucina-6/análise , MicroRNAs/análise , Biomarcadores/análise , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Ouro/química , Limite de Detecção , Análise em Microsséries/instrumentação , Análise em Microsséries/métodos , Nanoestruturas/química , Dispositivos Ópticos , Testes Imediatos , Reprodutibilidade dos Testes , Sepse/diagnóstico
4.
ACS Sens ; 4(1): 52-60, 2019 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-30525470

RESUMO

Existing clinical methods for bacteria detection lack speed, sensitivity, and, importantly, point-of-care (PoC) applicability. Thus, finding ways to push the sensitivity of clinical PoC biosensing technologies is crucial. Here we report a portable PoC device based on lens-free interferometric microscopy (LIM). The device employs high performance nanoplasmonics and custom bioprinted microarrays and is capable of direct label-free bacteria ( E. coli) quantification. With only one-step sample handling we offer a sample-to-data turnaround time of 40 min. Our technology features detection sensitivity of a single bacterial cell both in buffer and in diluted blood plasma and is intrinsically limited by the number of cells present in the detection volume. When employed in a hospital setting, the device has enabled accurate categorization of sepsis patients (infectious SIRS) from control groups (healthy individuals and noninfectious SIRS patients) without false positives/negatives. User-friendly on-site bacterial clinical diagnosis can thus become a reality.


Assuntos
Técnicas Bacteriológicas/métodos , Sangue/microbiologia , Escherichia coli/isolamento & purificação , Interferometria/métodos , Microscopia/métodos , Testes Imediatos , Adsorção , Anticorpos Antibacterianos/química , Anticorpos Antibacterianos/imunologia , Carga Bacteriana/instrumentação , Carga Bacteriana/métodos , Proteínas de Bactérias/química , Técnicas Bacteriológicas/instrumentação , Bioimpressão , Escherichia coli/imunologia , Ouro/química , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Interferometria/instrumentação , Microscopia/instrumentação , Nanoestruturas/química , Análise Serial de Proteínas/instrumentação , Análise Serial de Proteínas/métodos , Sepse/sangue , Sepse/microbiologia
5.
Opt Express ; 26(22): 28938-28947, 2018 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-30470063

RESUMO

We put forward a simple, scalable and robust technique for generating periodically structured light beams with intensity patterns, e.g. of the form cos2n(kxx) cos2m(kyy), where kx and ky are real numbers that can be tailored and n and m are integers. The technique combines the use of Gaussian beams with curved wavefronts, birefringent crystals (Savart plates) and linear polarizers. Applications range from photolithography to fabrication of micro-lens array and fiber Bragg gratings, 3D printing and tailoring of optical lattices for trapping atoms and molecules.

6.
Light Sci Appl ; 7: 17152, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30839537

RESUMO

Nanophotonics, and more specifically plasmonics, provides a rich toolbox for biomolecular sensing, since the engineered metasurfaces can enhance light-matter interactions to unprecedented levels. So far, biosensing associated with high-quality factor plasmonic resonances has almost exclusively relied on detection of spectral shifts and their associated intensity changes. However, the phase response of the plasmonic resonances have rarely been exploited, mainly because this requires a more sophisticated optical arrangement. Here we present a new phase-sensitive platform for high-throughput and label-free biosensing enhanced by plasmonics. It employs specifically designed Au nanohole arrays and a large field-of-view interferometric lens-free imaging reader operating in a collinear optical path configuration. This unique combination allows the detection of atomically thin (angstrom-level) topographical features over large areas, enabling simultaneous reading of thousands of microarray elements. As the plasmonic chips are fabricated using scalable techniques and the imaging reader is built with low-cost off-the-shelf consumer electronic and optical components, the proposed platform is ideal for point-of-care ultrasensitive biomarker detection from small sample volumes. Our research opens new horizons for on-site disease diagnostics and remote health monitoring.

7.
Opt Lett ; 42(13): 2487-2490, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28957265

RESUMO

We unveil different regimes for the interaction between two orthogonally polarized soliton-like beams in a colloidal suspension of nanoparticles with positive polarizability. The interaction is always attractive. However, it noticeably changes as a function of the angle and the power distribution between the input beams. For small angles, both interacting solitons fuse into a single entity, whose propagation direction can be continuously steered. As the interaction angle increases, the resulting self-collimated beam can be practically switched between two positions when the power imbalance between the beams is changed. For interaction angles larger than ∼10°, the result is no longer a single emerging soliton when the input power is balanced between the two beams.

8.
Sci Adv ; 2(6): e1600077, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27386571

RESUMO

Light microscopes can detect objects through several physical processes, such as scattering, absorption, and reflection. In transparent objects, these mechanisms are often too weak, and interference effects are more suitable to observe the tiny refractive index variations that produce phase shifts. We propose an on-chip microscope design that exploits birefringence in an unconventional geometry. It makes use of two sheared and quasi-overlapped illuminating beams experiencing relative phase shifts when going through the object, and a complementary metal-oxide-semiconductor image sensor array to record the resulting interference pattern. Unlike conventional microscopes, the beams are unfocused, leading to a very large field of view (20 mm(2)) and detection volume (more than 0.5 cm(3)), at the expense of lateral resolution. The high axial sensitivity (<1 nm) achieved using a novel phase-shifting interferometric operation makes the proposed device ideal for examining transparent substrates and reading microarrays of biomarkers. This is demonstrated by detecting nanometer-thick surface modulations on glass and single and double protein layers.


Assuntos
Microscopia de Interferência/métodos , Desenho de Equipamento , Microscopia de Interferência/instrumentação , Microscopia de Interferência/normas , Microscopia de Contraste de Fase , Imagem Molecular/métodos , Sensibilidade e Especificidade
9.
Opt Lett ; 38(24): 5284-7, 2013 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-24322238

RESUMO

We experimentally demonstrate guiding of a low-power probe beam (633 nm wavelength) by means of a light-induced waveguide generated by the self-focusing of a strong pump beam (532 nm wavelength) in an artificial nonlinear medium, constituted by a colloidal suspension of dielectric nanoparticles. We also demonstrate optical steering of the probe beam by controlling the direction of propagation of the pump beam. The distance over which guiding is demonstrated (5 mm) is remarkably long when compared with previous experiments.

10.
Opt Express ; 21(3): 3379-87, 2013 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-23481798

RESUMO

We present a method to measure the skew angle of the wave-fronts in an optical vortex, which is directly related with the energy flux. It is based on the analysis of the evolution on propagation of the near-field diffraction pattern generated by a single-slit, consisting of two main lobes that shift in opposite directions depending on the vortex helicity. The transverse displacement of each lobe as a function of the propagation distance allows to quantify the energy circulation. Analytical, numerical and experimental results are compared, showing good agreement. We illustrate the method for the case of Bessel beams, although we also discuss other types of helical beams, such as Laguerre-Gauss and Mathieu beams.