Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Tech Coloproctol ; 24(5): 449-454, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32107682

RESUMO

BACKGROUND: Anastomotic leakage (AL) remains a severe complication following colorectal surgery, having a negative impact on both short- and long-term outcomes. Since timely detection could enable early intervention, there is a need for the development of novel and accurate, preferably, non-invasive markers. The aim of this study was to investigate whether urinary intestinal fatty acid binding protein (I-FABP) could serve as such a marker. METHODS: This prospective multicenter cross-sectional phase two diagnostic study was conducted at four centers in the Netherlands between March 2015 and November 2016. Urine samples of 15 patients with confirmed colorectal AL and 19 patients without colorectal AL on postoperative day 3 were included. Urinary I-FABP levels were determined using enzyme-linked immunosorbent assays and adjusted for urinary creatinine to compensate for renal dysfunction. RESULTS: Urinary I-FABP levels were significantly elevated in patients with confirmed AL compared to patients without AL on postoperative day 3 (median: 2.570 ng/ml vs 0.809 ng/ml, p = 0.006). The area under the receiver operating characteristics curve (AUROC) was 0.775, yielding a sensitivity of 80% and specificity of 74% at the optimal cutoff point (> 1.589 ng/ml). This difference remained significant after calculation of I-FABP/creatinine ratios (median: 0.564 ng/µmol vs. 0.158 ng/µmol, p = 0.040), with an AUROC of 0.709, sensitivity of 60% and specificity of 90% at the optimal cutoff point (> 0.469 ng/µmol). CONCLUSIONS: Levels of urinary I-FABP and urinary I-FABP/creatinine were significantly elevated in patients with confirmed AL following colorectal surgery, suggesting their potential as a non-invasive biomarker for colorectal anastomotic leakage.


Assuntos
Fístula Anastomótica , Neoplasias Colorretais , Fístula Anastomótica/diagnóstico , Fístula Anastomótica/etiologia , Biomarcadores , Estudos Transversais , Proteínas de Ligação a Ácido Graxo , Humanos , Países Baixos , Estudos Prospectivos , Curva ROC
2.
Colorectal Dis ; 21(11): 1249-1258, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31207011

RESUMO

AIM: Inflammatory markers such as serum C-reactive protein (CRP) are used as routine markers to detect anastomotic leakage following colorectal surgery. However, CRP is characterized by a relatively low predictive value, emphasizing the need for the development of novel diagnostic approaches. Volatile organic compounds (VOCs) are gaseous metabolic products deriving from all conceivable bodily excrements and reflect (alterations in) the patient's physical status. Therefore, VOCs are increasingly considered as potential non-invasive diagnostic biomarkers. The aim of this study was to assess the diagnostic accuracy of urinary VOCs for colorectal anastomotic leakage. METHODS: In this explorative multicentre study, urinary VOC profiles of 22 patients with confirmed anastomotic leakage and 27 uneventful control patients following colorectal surgery were analysed by field asymmetric ion mobility spectrometry (FAIMS). RESULTS: Urinary VOCs of patients with anastomotic leakage could be distinguished from those of control patients with high accuracy: area under the receiver operating characteristics curve 0.91 (95% CI 0.81-1.00, P < 0.001), sensitivity 86% and specificity 93%. Serum CRP was significantly increased in patients with a confirmed anastomotic leak but with lower diagnostic accuracy compared to VOC analysis (area under the receiver operating characteristics curve 0.82, 95% CI 0.68-0.95, P < 0.001). Combining VOCs and CRP did not result in a significant improvement of the diagnostic performance compared to VOCs alone. CONCLUSION: Analysis by FAIMS allowed for discrimination between urinary VOC profiles of patients with a confirmed anastomotic leak and control patients following colorectal surgery. A superior accuracy compared to CRP and apparently high specificity was observed, underlining the potential as a non-invasive biomarker for the detection of colorectal anastomotic leakage.


Assuntos
Fístula Anastomótica/diagnóstico , Colo/cirurgia , Espectrometria de Mobilidade Iônica/estatística & dados numéricos , Reto/cirurgia , Compostos Orgânicos Voláteis/urina , Adulto , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica/efeitos adversos , Biomarcadores/urina , Colostomia/efeitos adversos , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Rev Sci Instrum ; 89(10): 10J116, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399907

RESUMO

In situ probes are being developed to make direct, spatially resolved measurements of the ion energy spectra in the edge of tokamak plasmas while being easily replaced and requiring minimal resources. The ion spectrometers will consist of a combined collimator and energy analyzer fabricated from silicon and mated to a detector to yield a form factor of approximately 2.0 cm × 1.5 cm × 0.2 cm. Results of fabrication and testing of the combined collimator and energy analyzer element are presented.

4.
Phys Med Biol ; 62(23): L41-L50, 2017 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-29135471

RESUMO

The integration of 1.5 T MRI functionality with a radiotherapy linear accelerator (linac) has been pursued since 1999 by the UMC Utrecht in close collaboration with Elekta and Philips. The idea behind this integrated device is to offer unrivalled, online and real-time, soft-tissue visualization of the tumour and the surroundings for more precise radiation delivery. The proof of concept of this device was given in 2009 by demonstrating simultaneous irradiation and MR imaging on phantoms, since then the device has been further developed and commercialized by Elekta. The aim of this work is to demonstrate the clinical feasibility of online, high-precision, high-field MRI guidance of radiotherapy using the first clinical prototype MRI-Linac. Four patients with lumbar spine bone metastases were treated with a 3 or 5 beam step-and-shoot IMRT plan. The IMRT plan was created while the patient was on the treatment table and based on the online 1.5 T MR images; pre-treatment CT was deformably registered to the online MRI to obtain Hounsfield values. Bone metastases were chosen as the first site as these tumors can be clearly visualized on MRI and the surrounding spine bone can be detected on the integrated portal imager. This way the portal images served as an independent verification of the MRI based guidance to quantify the geometric precision of radiation delivery. Dosimetric accuracy was assessed post-treatment from phantom measurements with an ionization chamber and film. Absolute doses were found to be highly accurate, with deviations ranging from 0.0% to 1.7% in the isocenter. The geometrical, MRI based targeting as confirmed using portal images was better than 0.5 mm, ranging from 0.2 mm to 0.4 mm. In conclusion, high precision, high-field, 1.5 T MRI guided radiotherapy is clinically feasible.


Assuntos
Neoplasias Ósseas/radioterapia , Região Lombossacral/efeitos da radiação , Imageamento por Ressonância Magnética/instrumentação , Aceleradores de Partículas/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Neoplasias da Coluna Vertebral/radioterapia , Idoso , Neoplasias Ósseas/secundário , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Neoplasias da Coluna Vertebral/patologia
5.
Rev Sci Instrum ; 87(11): 11D302, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910531

RESUMO

A plasma spectrometer design based on advances in lithography and microchip stacking technologies is described. A series of curved plate energy analyzers, with an integrated collimator, is etched into a silicon wafer. Tests of spectrometer elements, the energy analyzer and collimator, were performed with a 5 keV electron beam. The measured collimator transmission and energy selectivity were in good agreement with design targets. A single wafer element could be used as a plasma processing or fusion first wall diagnostic.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...