Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
3.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930026

RESUMO

Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively.

4.
G Ital Cardiol (Rome) ; 25(6): 16-22, 2024 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-38912743

RESUMO

Over the last few decades, endovascular revascularization techniques have revolutionized the treatment of peripheral artery disease, offering a less invasive alternative to surgery. However, the successful treatment of heavily calcified lesions is often compromised by various vascular complications, including recoils, dissections, and the need for target vessel reinterventions. This has prompted the development of several tools for lesion preparation, with the aim of achieving better procedural outcomes. This review aims to summarize the main characteristics and current evidence related to the available devices for preparing severely calcified peripheral lesions.


Assuntos
Procedimentos Endovasculares , Doença Arterial Periférica , Calcificação Vascular , Humanos , Procedimentos Endovasculares/métodos , Doença Arterial Periférica/terapia , Doença Arterial Periférica/cirurgia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Índice de Gravidade de Doença
5.
Catheter Cardiovasc Interv ; 103(7): 1125-1137, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38639140

RESUMO

BACKGROUND: Despite the use of two crossed Perclose ProGlide™ (Abbott Vascular Devices) is the most widespread technique to close the main arterial access in transfemoral transcatheter aortic valve implantation (TF-TAVI), the safest and most effective strategy still remains much debated. AIMS: The aim of the present study was to evaluate the performance of a single Perclose ProGlide suture-mediated closure device to obtain femoral hemostasis after sheathless implantation of self-expanding transcatheter heart valves through their 14 F-equivalent fix delivery systems. METHODS: This prospective observational study included 439 patients undergoing TF-TAVI at the "Montevergine" Clinic of Mercogliano, Italy. All patients underwent hemostasis of the large-bore access using a single Perclose ProGlide with preclose technique, after sheathless implantation of self-expanding transcatheter heart valves through 14 F-equivalent fix delivery systems. A multidetector computed tomography analysis of size, tortuosity, atherosclerotic, and calcification burdens of the ilio-femoral access route was made by a dedicated corelab. Vascular complications (VCs), percutaneous closure device (PCD) failure, and bleedings were adjudicated by a clinical events committee. RESULTS: A total of 81 different VCs were observed in 60 patients (13.7%); among these, 41 (5% of patients) were categorized as major. PCD failure occurred in 14 patients (3.2%). At the logistic regression analysis, no predictors of PCD failure have been identified. CONCLUSION: This registry suggests that the use of a single suture-mediated closure device could be considered a safe and efficient technique to achieve access site hemostasis in patients undergoing TF-TAVI through 14 F-equivalent fix delivery systems.


Assuntos
Cateterismo Periférico , Artéria Femoral , Técnicas Hemostáticas , Punções , Técnicas de Sutura , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Artéria Femoral/diagnóstico por imagem , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Cateterismo Periférico/efeitos adversos , Idoso , Técnicas Hemostáticas/instrumentação , Técnicas Hemostáticas/efeitos adversos , Técnicas de Sutura/efeitos adversos , Técnicas de Sutura/instrumentação , Fatores de Risco , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Itália , Desenho de Equipamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Hemorragia/etiologia , Hemorragia/prevenção & controle
6.
Int Heart J ; 65(1): 146-151, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38296568

RESUMO

A 36-year-old woman suffered from an embolic stroke of an undetermined source documented by magnetic resonance imaging with residual right arm weakness. She underwent percutaneous patent foramen ovale (PFO) closure with an 18/25 mm device in another center. One year later, the patient suffered from a transient ischemic attack with dysarthria. She asked for a second opinion at our institution and a contrast-transthoracic (cTTE) /transesophageal echocardiography showed a large residual right-to-left shunt (RLS) through a still patent tunnel after PFO closure. Written informed consent for a redo procedure was obtained from the patient. A catheter-based closure of the residual shunt was therefore planned under local anesthesia and rotational intracardiac echo monitoring. A second equally sized disc (18/18 mm) device was successfully implanted without complications. The patient was discharged home the following day in good clinical condition. Dual antiplatelet therapy was recommended for the first 2 months and then single antiplatelet therapy up to 6 months. At the 6-month follow-up, the cTTE color Doppler showed the stable position of the two nitinol double-disc devices and the c-transcranial Doppler confirmed the abolition of the residual RLS.


Assuntos
Forame Oval Patente , Ataque Isquêmico Transitório , AVC Isquêmico , Adulto , Feminino , Humanos , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Forame Oval Patente/cirurgia , Ataque Isquêmico Transitório/epidemiologia , AVC Isquêmico/epidemiologia , Resultado do Tratamento
7.
J Endovasc Ther ; : 15266028231217657, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38084379

RESUMO

PURPOSE: The aim of this study was to assess the efficacy and safety of the novel SLR (SELUTION sustained-limus-release) drug-coated balloon (DCB) in the treatment of the femoropopliteal steno-occlusive disease. MATERIALS AND METHODS: From February 2021 to March 2022, 80 consecutive patients (age: 69.5±8.23 years; total number of lesions: 80) with a steno-occlusive lesion of superficial femoral artery were enrolled at our center. A total of 60 patients (75%) had claudication, whereas 20 (25%) had chronic limb-threatening ischemia (CLTI). The mean lesion length was 171±82.22 mm. The primary efficacy outcome was primary patency at 12 months, defined as freedom from restenosis determined by a duplex ultrasound peak systolic velocity ratio ≤2.4. The secondary efficacy outcome was freedom from clinically-driven target lesion revascularization (CD-TLR) at 12 months. The primary safety outcome was a composite of freedom from device- and procedure-related mortality, major target limb amputation, and clinically-driven target lesion urgent revascularization (endovascular or bypass graft) at 30 days and 12 months. RESULTS: Device success was achieved in all 80 patients. One death on day 7 from cardiovascular complications was ruled procedure-related because it occurred within the first 30 days from the discharge. Two patients with CLTI experienced planned minor amputations of target limb, and one patient underwent urgent bypass graft of the target vessel for early occlusion at 60 days from the index procedure. The primary safety outcome was 98.7% and 97.5% at 30 days and 12 months, respectively. At 1 year, primary patency was 86.3%, and freedom from CD-TLR was 96.2%. CONCLUSION: These findings suggest that using a novel sirolimus-coated balloon is a safe and effective treatment option for femoropopliteal steno-occlusive lesions in a variety of clinical and anatomical settings. These results will need to be confirmed by long-term follow-up and randomized controlled trials. CLINICAL IMPACT: In femoropopliteal steno-occlusive lesions paclitaxel drug-coated devices have been proved to be able to achieve a better vessel patency during follow-up compared with uncoated balloon, but according to a recent meta-analysis they may carry an elevated risk of late mortality. Sirolimus results in a wider therapeutic range with a 3-fold higher margin of safety. Sirolimus coated devices have recently been proposed as an alternative. This study suggests that using a novel sirolimus-coated balloon is a safe and effective treatment option for femoropopliteal steno-occlusive lesions.

8.
J Cardiovasc Dev Dis ; 10(11)2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37998517

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an almost totally cine-fluoroscopic guided procedure. The amount of radiation used during the procedure is strictly related to the fluoroscopy time (FT), that has already been demonstrated to be associated with outcomes and complexity of coronary procedures. The aim of our study is to demonstrate the relationship between FT and the short-term outcomes after TAVR defined by to the Valve Academic Research Consortium (VARC)-2 and -3 consensus documents. METHODS: After splitting 1797 consecutive patients into tertiles of FT, the composite endpoint early safety (ES) was adjudicated according to VARC-2 and VARC-3 definitions, whereas the composite endpoints device success (DS) and technical success (TS) according to VARC-3 criteria. RESULTS: The absence of all these outcomes (VARC-2 ES amd VARC-3 TS, DS, and ES) was significantly associated with longer FT: this association was independent from both intraprocedural complications and other intraprocedural factors linked to longer FT, and still persisted after propensity score matching analysis. Notwithstanding, after receiver operating characteristic analysis, FT had adequate diagnostic accuracy in identifying the absence of only VARC-3 TS and VARC-2 ES. CONCLUSION: Longer FT is related with periprocedural and short-term outcomes after the procedure, especially in those that are more challenging. A FT duration of more than 30 min has an adequate accuracy in identifying VARC-3 technical failure (TS and DS) and absence of VARC-2 ES, selecting patients who are likely to take advantage from more careful in-hospital follow-up.

9.
Resuscitation ; 193: 109981, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37778615

RESUMO

AIM: We hypothesized that adult patients with out-of-hospital cardiac arrest (OHCA) and ST-elevation myocardial infarction (STEMI) requiring prolonged resuscitation have more severe coronary artery disease (CAD) than those responding rapidly, and more severe CAD than patients with STEMI without OHCA. METHODS: Consecutive conscious and comatose OHCA patients with STEMI after reestablishment of spontaneous circulation (ROSC), and patients with refractory OHCA undergoing veno-arterial extracorporeal membrane oxygenation (E-CPR OHCA) were compared to STEMI without OHCA (STEMI no OHCA). CAD severity was assessed by a single physician blinded to the resuscitation method, time to ROSC and level of consciousness. RESULTS: Between 2016 and 2022, 71 conscious OHCA, 157 comatose OHCA, 50 E-CPR OHCA and 101 STEMI no OHCA underwent immediate coronary angiography. Acute culprit lesion was documented less often in OHCA (88.1% vs 97%; p = 0.009) but complete occlusion was more frequent (68.8% vs 58.4%; p = 0.038) than in STEMI no OHCA. SYNTAX score was 5.6 in STEMI no OHCA, 10.2 in conscious OHCA, 13.4 in comatose OHCA and 26.8 in E-CPR OHCA (p < 0.001). There was a linear correlation between SYNTAX score and delay to ROSC/ECMO initiation (r2 = 0.61; p < 0.001). Post PCI culprit TIMI 3 flow was comparable between the groups (≥86%). SYNTAX score was among independent predictors of 5-year survival which was significantly decreased in comatose OHCA (56.1%) and E-CPR OHCA (36.0%) compared to conscious OHCA (83.1%) and STEMI no OHCA (88.1%). CONCLUSION: Compared to STEMI no OHCA, OHCA was associated with increased incidence of acute coronary occlusion and more complex non culprit CAD which progressively increased from conscious OHCA to E-CPR OHCA. Severity of CAD was associated with increased delays to ROSC/ECMO initiation and decreased long term survival.


Assuntos
Reanimação Cardiopulmonar , Doença da Artéria Coronariana , Parada Cardíaca Extra-Hospitalar , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Adulto , Humanos , Doença da Artéria Coronariana/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Parada Cardíaca Extra-Hospitalar/etiologia , Parada Cardíaca Extra-Hospitalar/terapia , Coma/etiologia , Resultado do Tratamento , Angiografia Coronária/efeitos adversos , Reanimação Cardiopulmonar/métodos
10.
Am Heart J ; 265: 153-160, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37572785

RESUMO

BACKGROUND: Over the past few decades, percutaneous coronary intervention (PCI) has undergone significant advancements as a result of the combination of device-based and drug-based therapies. These iterations have led to the development of polymer-free drug-eluting stents. However, there is a scarcity of data regarding their clinical performance. Furthermore, while various risk scores have been proposed to determine the optimal duration of dual antiplatelet therapy (DAPT), none of them have undergone prospective validation within the context of randomized trials. DESIGN: The PARTHENOPE trial is a phase IV, prospective, randomized, multicenter, investigator-initiated, assessor-blind study being conducted at 14 centers in Italy (NCT04135989). It includes 2,107 all-comers patients with minimal exclusion criteria, randomly assigned in a 2-by-2 design to receive either the Cre8 amphilimus-eluting stent or the SYNERGY everolimus-eluting stent, along with either a personalized or standard duration of DAPT. Personalized DAPT duration is determined by the DAPT score, which accounts for both bleeding and ischemic risks. Patients with a DAPT score <2 (indicating higher bleeding than ischemic risk) receive DAPT for 3 or 6 months for chronic or acute coronary syndrome, respectively, while patients with a DAPT score ≥2 (indicating higher ischemic than bleeding risk) receive DAPT for 24 months. Patients in the standard DAPT group receive DAPT for 12 months. The trial aims to establish the noninferiority between stents with respect to a device-oriented composite end point of cardiovascular death, target-vessel myocardial infarction, or clinically-driven target-lesion revascularization at 12 months after PCI. Additionally, the trial aims to demonstrate the superiority of personalized DAPT compared to a standard approach with respect to a net clinical composite of all-cause death, any myocardial infarction, stroke, urgent target-vessel revascularization, or type 2 to 5 bleeding according to the Bleeding Academic Research Consortium criteria at 24-months after PCI. SUMMARY: The PARTHENOPE trial is the largest randomized trial investigating the efficacy and safety of a polymer-free DES with a reservoir technology for drug-release and the first trial evaluating a personalized duration of DAPT based on the DAPT score. The study results will provide novel insights into the optimizing the use of drug-eluting stents and DAPT in patients undergoing PCI.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Inibidores da Agregação Plaquetária/uso terapêutico , Stents Farmacológicos/efeitos adversos , Intervenção Coronária Percutânea/métodos , Polímeros , Hemorragia/induzido quimicamente , Infarto do Miocárdio/etiologia , Resultado do Tratamento , Quimioterapia Combinada
11.
EuroIntervention ; 19(7): 589-599, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37436190

RESUMO

BACKGROUND: The optimal timing to perform percutaneous coronary interventions (PCI) in transcatheter aortic valve implantation (TAVI) patients remains unknown. AIMS: We sought to compare different PCI timing strategies in TAVI patients. METHODS: The REVASC-TAVI registry is an international registry including patients undergoing TAVI with significant, stable coronary artery disease (CAD) at preprocedural workup. In this analysis, patients scheduled to undergo PCI before, after or concomitantly with TAVI were included. The main endpoints were all-cause death and a composite of all-cause death, stroke, myocardial infarction (MI) or rehospitalisation for congestive heart failure (CHF) at 2 years. Outcomes were adjusted using the inverse probability treatment weighting (IPTW) method. RESULTS: A total of 1,603 patients were included. PCI was performed before, after or concomitantly with TAVI in 65.6% (n=1,052), 9.8% (n=157) or 24.6% (n=394), respectively. At 2 years, all-cause death was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (6.8% vs 20.1% vs 20.6%; p<0.001). Likewise, the composite endpoint was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (17.4% vs 30.4% vs 30.0%; p=0.003). Results were confirmed at landmark analyses considering events from 0 to 30 days and from 31 to 720 days. CONCLUSIONS: In patients with severe aortic stenosis and stable coronary artery disease scheduled for TAVI, performance of PCI after TAVI seems to be associated with improved 2-year clinical outcomes compared with other revascularisation timing strategies. These results need to be confirmed in randomised clinical trials.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Intervenção Coronária Percutânea/métodos , Estenose da Valva Aórtica/terapia , Infarto do Miocárdio/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
12.
Hypertension ; 80(9): 1800-1809, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37403685

RESUMO

SGLT2 (sodium-glucose cotransporter 2) enables glucose and sodium reabsorption in the kidney. SGLT2-inhibitors (also known as gliflozins, which include canagliflozin, dapagliflozin, empagliflozin, and ertugliflozin) act by increasing glycosuria, thereby reducing glycemia. These drugs are critical to reach and keep glycemic control, a crucial feature, especially in patients with comorbidities, like frail individuals. Several studies evaluated the effects of SGLT2-inhibitors in different settings beyond diabetes, revealing that they are actually pleiotropic drugs. We recently evidenced the favorable effects of SGLT2-inhibition on physical and cognitive impairment in frail older adults with diabetes and hypertension. In the present overview, we summarize the latest clinical and preclinical studies exploring the main effects of SGLT2-inhibitors on kidney and heart, emphasizing their potential beneficial actions in frailty.


Assuntos
Diabetes Mellitus Tipo 2 , Fragilidade , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Idoso , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico , Inibidores do Transportador 2 de Sódio-Glicose/farmacologia , Hipoglicemiantes/farmacologia , Transportador 2 de Glucose-Sódio/farmacologia , Relevância Clínica , Rim , Glucose , Compostos Benzidrílicos/farmacologia , Compostos Benzidrílicos/uso terapêutico , Sódio
13.
Echocardiography ; 40(8): 768-774, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37342979

RESUMO

BACKGROUND: Aortic valve stenosis (AS) is the most common valvular heart disease worldwide. When timely intervention is performed, aortic valve replacement can improve patients' quality and duration of life. Load-independent left ventricular (LV) functional assessments, such as myocardial work indices (MWIs) and LV diastolic function parameters, could help clinicians decide on the optimal timing of intervention. AIMS: To evaluate the reliability of MWI in AS patients and the changes in MWI and LV diastolic function after transcatheter aortic valve replacement (TAVR). METHODS: We enrolled 53 consecutive patients with severe AS undergoing TAVR admitted between March 2021 and November 2021. MWIs and LV diastolic function were assessed before and after TAVR for each patient. RESULTS: All MWIs and LV diastolic function indices improved after TAVR. The degree of MWIs improvement was higher in patients with lower prior-TAVR MWI values, while the more severe the impairment of diastolic function, the greater the post-TAVR benefit. CONCLUSION: The introduction of myocardial work parameters into the routine assessment of patients with AS could improve our understanding of cardiac performance and aid in identifying the optimal timing for surgical or percutaneous treatment.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Reprodutibilidade dos Testes , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Função Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Estudos Retrospectivos
14.
J Cardiovasc Dev Dis ; 10(6)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37367409

RESUMO

BACKGROUND: Surgical mortality risk scores, even if not properly designed and rarely tested in the transcatheter aortic valve implantation (TAVI) setting, still guide the heart team in managing significant aortic stenosis. METHODS: After splitting 1763 consecutive patients retrospectively based on their mortality risk thresholds, the composite endpoint early safety (ES) was adjudicated according to Valve Academic Research Consortium (VARC)-2 and -3 consensus documents. RESULTS: ES incidence was higher if VARC-2 rather than VARC-3 defined. Despite only patients showing VARC-2 ES had significantly lower absolute values of all three main risk scores, these last still failed to foresee both VARC-2 and -3 ES in intermediate-risk patients. The receiver operating characteristic analysis also showed a significant correlation, but with poor diagnostic accuracy, among the three scores and only VARC-2 ES; moreover, the absence of VARC-2 ES and low-osmolar contrast media administration were identified as independent predictors of 1-year mortality and absence of VARC-3 ES, respectively. Finally, even a single complication included in the ES definition could significantly affect 1-year mortality. CONCLUSION: Currently, the most used mortality risk scores do not have adequate diagnostic accuracy in predicting ES after TAVI. The absence of VARC-2, instead of VARC-3, ES is an independent predictor of 1-year mortality.

16.
Mech Ageing Dev ; 212: 111818, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37116731

RESUMO

BACKGROUND: Cardiac fibrosis represents a key element in the pathophysiology of heart failure with preserved ejection fraction (HFpEF), a condition highly prevalent amongst geriatric patients, especially if diabetic. The microRNA 181c (miR-181c) has been shown to be associated with the response to exercise training in HFpEF patients and has been also linked to diabetic cardiovascular complications. However, the underlying mechanisms have not been fully elucidated. OBJECTIVE: To measure circulating miR-181c in elderly patients with HFpEF and diabetes mellitus (DM) and identify gene targets pathophysiologically relevant in HFpEF. METHODS: We quantified circulating miR-181c in frail older adults with a confirmed diagnosis of HFpEF and DM, and, as control, we enrolled age-matched subjects without HFpEF and without DM. We validated in human cardiac fibroblasts the molecular mechanisms linking miR-181c to a pro-fibrotic response. RESULTS: 51 frail patients were included :34 patients with DM and HFpEF and 17 age-matched controls. We observed that miR-181c was significantly upregulated (p < 0.0001) in HFpEF patients vs controls. We confirmed in vitro that miR-181c is targeting PRKN and SMAD7. CONCLUSIONS: We demonstrate that miR-181c levels are significantly increased in frail elderly adults with DM and HFpEF and that miR-181c targets PRKN and SMAD7 in human cardiac fibroblasts.


Assuntos
Diabetes Mellitus , Insuficiência Cardíaca , MicroRNAs , Humanos , Idoso , Insuficiência Cardíaca/genética , Insuficiência Cardíaca/metabolismo , Volume Sistólico/fisiologia , Fibrose , MicroRNAs/genética , MicroRNAs/metabolismo , Fibroblastos/metabolismo , Ubiquitina-Proteína Ligases/metabolismo , Proteína Smad7/genética , Proteína Smad7/metabolismo
17.
Diagnostics (Basel) ; 13(7)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37046483

RESUMO

Carotid artery stenting (CAS) is usually performed through a femoral vascular access using 6-9 Fr guiding catheters. We investigated whether a systematic distal radial approach using 5 Fr guiding sheaths was a safe and effective alternative to transfemoral approach for CAS. From July 2020 to October 2022, two operators at our center systematically performed CAS using a 5 Fr distal radial approach in consecutive patients. The main endpoints of the study were procedural success via distal radial and via proximal or distal radial access. The learning curve was evaluated by comparing the first half of patients versus the second half of patients enrolled. Procedural data and 30-day clinical outcomes were collected. Fifty-one patients were prospectively enrolled. CAS was effectively performed via distal radial access in 45 patients (88%). Overall radial artery success was 92%. Distal radial CAS was successfully performed in 20 out of the first 25 patients enrolled (80%), and in 25 of the last 26 patients enrolled (96%; p = 0.07). Significantly less contrast was administered in the last 26 patients compared to the first 25 enrolled (110 (70, 140) mL vs. 120 (107, 150) mL; p = 0.045). Radial artery occlusion was reported in 1 patient (2%). Only 1 minor stroke (2%) was reported in-hospital and at 30-day follow-up. In conclusion, distal radial CAS using 5 Fr catheters was a safe procedure with a high success rate. The procedure had a relatively short learning curve in operators familiar with transfemoral CAS.

18.
Cardiovasc Diabetol ; 22(1): 89, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-37072850

RESUMO

L-Arginine (L-Arg), is a semi-essential amino acid involved in the formation of nitric oxide. The functional relevance of L-Arg in diabetes mellitus has been evaluated both in animal models and in human subjects. In the literature there are several lines of evidence indicating that L-Arg has beneficial effects in diabetes and numerous studies advocate its administration to attenuate glucose intolerance in diabetic patients. Here we present a comprehensive overview of the main studies exploring the effects of L-Arg in diabetes, including preclinical and clinical reports on this topic.


Assuntos
Diabetes Mellitus , Intolerância à Glucose , Animais , Humanos , Arginina/metabolismo , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/tratamento farmacológico , Óxido Nítrico/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...