Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Craniovertebr Junction Spine ; 15(2): 141-152, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38957769

RESUMO

Background: Anterior cervical discectomy and fusion (ACDF) is one of the most frequently performed cervical surgeries in the world, yet there have been several reported complications. Objective: To determine the actual incidence of complications related to ACDF as well as any risk variables that may have been identified in earlier research. Methods: To evaluate the origin, presentation, natural history, and management of the risks and the complications, we conducted a thorough assessment of the pertinent literature. An evaluation of clinical trials and case studies of patients who experienced one or more complications following ACDF surgery was done using a PubMed, Cochrane Library, and Google Scholar search. Studies involving adult human subjects that were written in the English language and published between 2012 and 2022 were included in the search. The search yielded 79 studies meeting our criteria. Results: The overall rates of complications were as follows: Dysphagia 7.9%, psudarthrosis 5.8%, adjacent segment disease (ASD) 8.8%, esophageal perforations (EPs) 0.5%, graft or hardware failure 2.2%, infection 0.3%, recurrent laryngeal nerve palsy 1.7%, cerebrospinal fluid leak 0.8%, Horner syndrome 0.5%, hematoma 0.8%, and C5 palsy 1.9%. Conclusion: Results showed that dysphagia was a common postoperative sequelae with bone morphogenetic protein use and a higher number of surgical levels being the major risk factors. Pseudarthrosis rates varied depending on the factors such as asymptomatic radiographic graft sinking, neck pain, or radiculopathy necessitating revision surgery. The incidence of ASD indicated no data to support anterior cervical plating as more effective than standalone ACDF. EP was rare but frequently fatal, with no correlation found between patient age, sex, body mass index, operation time, or number of levels.

2.
Indian J Anaesth ; 66(Suppl 2): S102-S107, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35601040

RESUMO

Background and Aims: Preprocedural ultrasound (US) assisted and real-time US-guided subarachnoid block (SAB) are useful adjuncts for successful SAB. This study compared the feasibility and efficacy of real-time US-guided SAB with preprocedural US-assisted and landmark-based SAB using paramedian approach. Methods: The study enroled 150 American Society of Anesthesiologists I and II patients, aged 20-65 years, scheduled for lower limb orthopaedic surgery under SAB. In group L (n = 50), the patients underwent landmark-guided SAB utilising paramedian approach. In group P (n = 50), preprocedural US-assisted SAB was instituted and in group M (n = 50) real-time US-guided SAB was administered. The number of needle attempts for a successful SAB was the primary outcome. The secondary outcomes included successful SAB in first attempt, time taken to perform SAB and patients' satisfaction. Results: The number of attempts for SAB were (mean ± standard deviation = 1.05 ± 0.35, 1.00 ± 0.28, 1.03 ± 0.26) in groups L, P and M, respectively (P = 0.436). The SAB was successful in the first attempt in 82%, 82% and 80% in groups L, P and M, respectively (P = 0.207). The time taken for the successful SAB was more in group M as compared to groups L and P (groups L and M, P = 0.045 and groups P and M, P = 0.004). The patients' satisfaction score was comparable. Conclusion: Real-time US guidance for spinal anaesthesia resulted in needle attempts comparable to landmark and preprocedural US-assisted SAB in patients with a normal spine. The time required for the completion of the block was more in real-time US-guided SAB.

3.
Pol J Radiol ; 81: 491-497, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27800039

RESUMO

BACKGROUND: To evaluate the accuracy of high resolution ultrasound (USG) and MRI in the diagnosis of rotator cuff tears (RCT) and to determine if high resolution USG compares favorably in sensitivity and specificity to MRI in the diagnosis of rotator cuff injury. MATERIAL/METHODS: In this prospective comparative study, 40 patients with clinically suspected rotator cuff tears underwent both ultrasound and MRI of the shoulder. Out of these 40 patients, 31 patients who had positive findings for rotator cuff tears on ultrasound and/or MRI were finally included in the study while the remaining 9 patients with negative or unrelated findings were excluded. The USG and MRI were interpreted by two radiologists experienced in musculoskeletal radiology and blinded to findings of each other. Comparison was done using MRI as a standard reference. RESULTS: The agreement between USG and MRI for diagnosis of RCTs was statistically excellent; USG showed a sensitivity of 86.7% and a specificity of 100% for full-thickness tears, and a sensitivity of 89.7% and a specificity of 98.8% for partial-thickness tears; observed accuracy for full thickness tears was 98.4% and 95.9% for partial thickness tears. The Kappa coefficient of association was 0.91 for full thickness tears and 0.90 for partial thickness tears. CONCLUSIONS: Considering the comparable diagnostic accuracy of USG and MRI, the former modality can be used as a first-line investigation for diagnosis of RCT. MRI should be used secondarily as a problem-solving tool either following an equivocal shoulder USG or for delineation of anatomy in cases where surgical correction is needed.

4.
J Surg Tech Case Rep ; 4(1): 15-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23066456

RESUMO

BACKGROUND: Distal interlocking screw insertion in intramedullary nailing of long-bone fracture is a challenging task for orthopedic surgeons. It is difficult particularly when the surgeon is in his learning stage or when image intensifier is not available. We describe a radiation-free technique of distal interlocking screw insertion which is easy and practicable. MATERIALS AND METHODS: In this technique, a same length nail is placed over the skin (outer nail) and through its distal-most screw hole, a 3.2 mm drill bit is inserted to drill the distal locking screw hole of the intramedullary nail (inner nail). With a small skin incision over the distal screw holes, the distal-most screw hole is identified; the bone window overlying the screw hole is widened with an awl and a locking bolt is inserted with a washer under direct visualization. The other distal interlocking screw is simply drilled by matching the other three holes of the outer and inner nails. We have operated 86 patients (39 femoral shaft fracture and 47 tibial shaft fracture) in 1 year where this technique was used. There were 41 open fracture and 45 closed fracture. RESULTS: Within 6 months of follow-up, bony union was achieved in 36 of 39 femur fractures and 45 of 47 tibial fractures. No unwanted complications were observed during the postoperative period and in follow-up. CONCLUSION: This method of radiation-free distal interlocking screw insertion is simple and can be used in third world country where image intensifier facility is not available. However, surgeons are encouraged to use image intensifier facility where the facility is available.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...