1.
Int J Neural Syst ; 33(3): 2350012, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36809996

RESUMO

Neurologists typically identify epileptic seizures from electroencephalograms (EEGs) by visual inspection. This process is often time-consuming, especially for EEG recordings that last hours or days. To expedite the process, a reliable, automated, and patient-independent seizure detector is essential. However, developing a patient-independent seizure detector is challenging as seizures exhibit diverse characteristics across patients and recording devices. In this study, we propose a patient-independent seizure detector to automatically detect seizures in both scalp EEG and intracranial EEG (iEEG). First, we deploy a convolutional neural network with transformers and belief matching loss to detect seizures in single-channel EEG segments. Next, we extract regional features from the channel-level outputs to detect seizures in multi-channel EEG segments. At last, we apply post-processing filters to the segment-level outputs to determine seizures' start and end points in multi-channel EEGs. Finally, we introduce the minimum overlap evaluation scoring as an evaluation metric that accounts for minimum overlap between the detection and seizure, improving upon existing assessment metrics. We trained the seizure detector on the Temple University Hospital Seizure (TUH-SZ) dataset and evaluated it on five independent EEG datasets. We evaluate the systems with the following metrics: sensitivity (SEN), precision (PRE), and average and median false positive rate per hour (aFPR/h and mFPR/h). Across four adult scalp EEG and iEEG datasets, we obtained SEN of 0.617-1.00, PRE of 0.534-1.00, aFPR/h of 0.425-2.002, and mFPR/h of 0-1.003. The proposed seizure detector can detect seizures in adult EEGs and takes less than 15[Formula: see text]s for a 30[Formula: see text]min EEG. Hence, this system could aid clinicians in reliably identifying seizures expeditiously, allocating more time for devising proper treatment.


Assuntos
Epilepsia , Convulsões , Adulto , Humanos , Convulsões/diagnóstico , Eletroencefalografia , Epilepsia/diagnóstico , Eletrocorticografia , Redes Neurais de Computação , Algoritmos
2.
J Neural Eng ; 19(6)2022 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-36270485

RESUMO

Objective.Clinical diagnosis of epilepsy relies partially on identifying interictal epileptiform discharges (IEDs) in scalp electroencephalograms (EEGs). This process is expert-biased, tedious, and can delay the diagnosis procedure. Beyond automatically detecting IEDs, there are far fewer studies on automated methods to differentiate epileptic EEGs (potentially without IEDs) from normal EEGs. In addition, the diagnosis of epilepsy based on a single EEG tends to be low. Consequently, there is a strong need for automated systems for EEG interpretation. Traditionally, epilepsy diagnosis relies heavily on IEDs. However, since not all epileptic EEGs exhibit IEDs, it is essential to explore IED-independent EEG measures for epilepsy diagnosis. The main objective is to develop an automated system for detecting epileptic EEGs, both with or without IEDs. In order to detect epileptic EEGs without IEDs, it is crucial to include EEG features in the algorithm that are not directly related to IEDs.Approach.In this study, we explore the background characteristics of interictal EEG for automated and more reliable diagnosis of epilepsy. Specifically, we investigate features based on univariate temporal measures (UTMs), spectral, wavelet, Stockwell, connectivity, and graph metrics of EEGs, besides patient-related information (age and vigilance state). The evaluation is performed on a sizeable cohort of routine scalp EEGs (685 epileptic EEGs and 1229 normal EEGs) from five centers across Singapore, USA, and India.Main results.In comparison with the current literature, we obtained an improved Leave-One-Subject-Out (LOSO) cross-validation (CV) area under the curve (AUC) of 0.871 (Balanced Accuracy (BAC) of 80.9%) with a combination of three features (IED rate, and Daubechies and Morlet wavelets) for the classification of EEGs with IEDs vs. normal EEGs. The IED-independent feature UTM achieved a LOSO CV AUC of 0.809 (BAC of 74.4%). The inclusion of IED-independent features also helps to improve the EEG-level classification of epileptic EEGs with and without IEDs vs. normal EEGs, achieving an AUC of 0.822 (BAC of 77.6%) compared to 0.688 (BAC of 59.6%) for classification only based on the IED rate. Specifically, the addition of IED-independent features improved the BAC by 21% in detecting epileptic EEGs that do not contain IEDs.Significance.These results pave the way towards automated detection of epilepsy. We are one of the first to analyze epileptic EEGs without IEDs, thereby opening up an underexplored option in epilepsy diagnosis.


Assuntos
Eletroencefalografia , Epilepsia , Humanos , Eletroencefalografia/métodos , Epilepsia/diagnóstico
3.
Int J Neural Syst ; 31(8): 2150032, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34278972

RESUMO

Epilepsy diagnosis based on Interictal Epileptiform Discharges (IEDs) in scalp electroencephalograms (EEGs) is laborious and often subjective. Therefore, it is necessary to build an effective IED detector and an automatic method to classify IED-free versus IED EEGs. In this study, we evaluate features that may provide reliable IED detection and EEG classification. Specifically, we investigate the IED detector based on convolutional neural network (ConvNet) with different input features (temporal, spectral, and wavelet features). We explore different ConvNet architectures and types, including 1D (one-dimensional) ConvNet, 2D (two-dimensional) ConvNet, and noise injection at various layers. We evaluate the EEG classification performance on five independent datasets. The 1D ConvNet with preprocessed full-frequency EEG signal and frequency bands (delta, theta, alpha, beta) with Gaussian additive noise at the output layer achieved the best IED detection results with a false detection rate of 0.23/min at 90% sensitivity. The EEG classification system obtained a mean EEG classification Leave-One-Institution-Out (LOIO) cross-validation (CV) balanced accuracy (BAC) of 78.1% (area under the curve (AUC) of 0.839) and Leave-One-Subject-Out (LOSO) CV BAC of 79.5% (AUC of 0.856). Since the proposed classification system only takes a few seconds to analyze a 30-min routine EEG, it may help in reducing the human effort required for epilepsy diagnosis.


Assuntos
Aprendizado Profundo , Epilepsia , Eletroencefalografia , Epilepsia/diagnóstico , Humanos , Redes Neurais de Computação , Couro Cabeludo
4.
Int J Neural Syst ; 31(5): 2050074, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33438530

RESUMO

The diagnosis of epilepsy often relies on a reading of routine scalp electroencephalograms (EEGs). Since seizures are highly unlikely to be detected in a routine scalp EEG, the primary diagnosis depends heavily on the visual evaluation of Interictal Epileptiform Discharges (IEDs). This process is tedious, expert-centered, and delays the treatment plan. Consequently, the development of an automated, fast, and reliable epileptic EEG diagnostic system is essential. In this study, we propose a system to classify EEG as epileptic or normal based on multiple modalities extracted from the interictal EEG. The ensemble system consists of three components: a Convolutional Neural Network (CNN)-based IED detector, a Template Matching (TM)-based IED detector, and a spectral feature-based classifier. We evaluate the system on datasets from six centers from the USA, Singapore, and India. The system yields a mean Leave-One-Institution-Out (LOIO) cross-validation (CV) area under curve (AUC) of 0.826 (balanced accuracy (BAC) of 76.1%) and Leave-One-Subject-Out (LOSO) CV AUC of 0.812 (BAC of 74.8%). The LOIO results are found to be similar to the interrater agreement (IRA) reported in the literature for epileptic EEG classification. Moreover, as the proposed system can process routine EEGs in a few seconds, it may aid the clinicians in diagnosing epilepsy efficiently.


Assuntos
Epilepsia , Couro Cabeludo , Adulto , Eletroencefalografia , Epilepsia/diagnóstico , Humanos , Redes Neurais de Computação , Convulsões
5.
Int J Neural Syst ; 30(11): 2050030, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32812468

RESUMO

Visual evaluation of electroencephalogram (EEG) for Interictal Epileptiform Discharges (IEDs) as distinctive biomarkers of epilepsy has various limitations, including time-consuming reviews, steep learning curves, interobserver variability, and the need for specialized experts. The development of an automated IED detector is necessary to provide a faster and reliable diagnosis of epilepsy. In this paper, we propose an automated IED detector based on Convolutional Neural Networks (CNNs). We have evaluated the proposed IED detector on a sizable database of 554 scalp EEG recordings (84 epileptic patients and 461 nonepileptic subjects) recorded at Massachusetts General Hospital (MGH), Boston. The proposed CNN IED detector has achieved superior performance in comparison with conventional methods with a mean cross-validation area under the precision-recall curve (AUPRC) of 0.838[Formula: see text]±[Formula: see text]0.040 and false detection rate of 0.2[Formula: see text]±[Formula: see text]0.11 per minute for a sensitivity of 80%. We demonstrated the proposed system to be noninferior to 30 neurologists on a dataset from the Medical University of South Carolina (MUSC). Further, we clinically validated the system at National University Hospital (NUH), Singapore, with an agreement accuracy of 81.41% with a clinical expert. Moreover, the proposed system can be applied to EEG recordings with any arbitrary number of channels.


Assuntos
Epilepsia , Couro Cabeludo , Área Sob a Curva , Eletroencefalografia , Epilepsia/diagnóstico , Humanos , Redes Neurais de Computação
6.
J Neurosci Methods ; 345: 108884, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32730918

RESUMO

BACKGROUND: Autism Spectrum Disorder (ASD) is a neurodevelopmental disability with altered connectivity in brain networks. NEW METHOD: In this study, brain connections in Resting-state functional Magnetic Resonance Imaging (Rs-fMRI) of ASD and Typical Developing (TD) are analyzed by partial and full correlation methods such as Gaussian Graphical Least Absolute Shrinkage and Selection Operator (GLASSO), Max-Det Matrix Completion (MDMC), and Pearson Correlation Co-Efficient (PCCE). We investigated Functional Connectivity (FC) of ASD and TD brain from 238 functionally defined regions of interest. Furthermore, we constructed a series of feature sets by applying conditional random forests and conditional permutation importance. We built classifier models by Random Forest (RF), Oblique RF (ORF), Support Vector Machine (SVM), and Convolutional Neural Network (CNN) for each feature set. FC features are ranked based on p-value and we analyzed the top 20 FC features. RESULTS: We achieved a single-trial test accuracy of 72.5 %, though MDMC-SVM and PCCE-CNN pipelines. Further, PCCE-CNN pipeline gives better average test accuracy (70.31 %) and area under the curve (0.73) compared to other pipelines. We found that top-20 PCCE based FC features are from networks such as Dorsal Attention (DA), Cingulo-Opercular Task Control (COTC), somatosensory motor hand and subcortical. In addition, among top 20 PCCE features, many FC links are found between COTC and DA (4 connections) which helped to discriminate the ASD and TD. COMPARISON WITH EXISTING METHODS AND CONCLUSIONS: The generalized classifier models built in our study for highly heterogeneous participants perform better than previous studies with similar data sets and diagnostic groups.


Assuntos
Transtorno do Espectro Autista , Transtorno Autístico , Transtorno do Espectro Autista/diagnóstico por imagem , Transtorno Autístico/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Humanos , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS