1.
Can J Anaesth ; 58(6): 532-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21465320

RESUMO

PURPOSE: This study compared the Boussignac™ continuous positive airway pressure (CPAP) mask with the venturi face mask in terms of the postoperative PaO2/F(I)O2 (PF) ratio in morbidly obese patients after bariatric surgery. METHODS: Following hospital Research Ethics Board approval and written informed consent, morbidly obese (body mass index > 35 kg·m(-2)) patients undergoing bariatric surgery were recruited. The patients were anesthetized and laparoscopic Roux-en-Y gastric bypass was performed. Patients were assigned randomly to receive either the Boussignac (Boussignac Group) or the venturi face mask (Venturi Group) immediately after tracheal extubation. Patients were transported to the postanesthesia care unit, and the respective devices were applied for one hour. The PF ratio was recorded after tracheal intubation and at one hour and two hours post extubation. The percent forced expiratory volume (%FEV1) and the percent forced vital capacity (%FVC) were recorded preoperatively and at one hour and two hours post extubation. Independent Student's t tests were used for continuous variables, and the Chi square test was used for categorical variables. P < 0.05 was considered statistically significant. RESULTS: Eighty-one patients (Group Boussignac, n = 43; Group Venturi, n = 38) completed the study. Mean ages and body mass indices were similar in the two groups. At one hour post extubation, the PF ratio in the Boussignac Group was 361 (170) compared with 279 (91) in the Venturi Group (P = 0.007), and at two hours post extubation, the PF ratio in the Boussignac Group was 371 (162) compared with 323 (127) in the Venturi Group (P = 0.1). The postoperative %FEV(1) and %FVC were comparable in both groups at all time points. CONCLUSION: Compared with the venturi mask, the Boussignac CPAP mask improves the postoperative PF ratio in morbidly obese patients after bariatric surgery. The postoperative %FEV1 and %FVC are comparable for both groups.


Assuntos
Cirurgia Bariátrica , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Obesidade Mórbida/cirurgia , Oxigênio/sangue , Adulto , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/fisiopatologia , Capacidade Vital
2.
Can J Anaesth ; 57(10): 913-8, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20640542

RESUMO

PURPOSE: This study examined the effect of external fibreoptic bronchoscope (FOB) rotations on endotracheal tube (ETT) orientations at the glottic level. METHODS: Using a mannequin, a nasal FOB was inserted for image capture. A second FOB with a preloaded ETT taped to its top was inserted orally into mid-trachea. The FOB with the taped ETT was rotated as a unit in the axial plane to five different external angles (-90°, -45°, 0°, +45°, +90°). At each external rotation, the ETT was advanced into the trachea. The image of the ETT at the glottic level was captured. Endotracheal tube orientation was quantified according to the glottic zone faced by the ETT. The ETT orientations were compared amongst the five external FOB rotations using the Kruskal-Wallis Test, while the ETT orientations at -90°, -45°, +45°, and +90° FOB rotations were compared with 0° rotation using the Mann-Whitney U test. RESULTS: There was a significant difference in the ETT orientations amongst the five FOB rotations (P < 0.001). The ETT orientations at -90°, -45°, +45°, and +90° FOB rotations were different from the 0° rotation (P < 0.001 for all comparisons). A -90° FOB rotation was most effective in turning the ETT tip away from the right laryngeal structures and the interarytenoid tissue. CONCLUSION: With the ETT loaded on a FOB, rotation of the FOB prior to advancing the ETT is effective in changing the ETT orientation at the glottis. A -90° FOB rotation is most effective in turning the ETT tip away from the right laryngeal structures and interarytenoid tissue.


Assuntos
Broncoscopia/métodos , Glote , Intubação Intratraqueal/métodos , Broncoscópios , Tecnologia de Fibra Óptica , Humanos , Manequins , Rotação , Estatísticas não Paramétricas