Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Pharm ; 84(2): 347-59, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27222609

RESUMO

Efficacy assessments using a combination of baricitinib and methotrexate necessitate the development of an analytical method for the determination of both drugs in plasma with precision. A high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of baricitinib and methotrexate in rat plasma. Extraction of baricitinib, methotrexate, and tolbutamide (internal standard; IS) from 50 µL of rat plasma was carried out by protein precipitation with methanol. Chromatographic separation of the analytes was performed on the YMC pack ODS AM (150 mm × 4.6 mm, 5 µm) column under gradient conditions with methanol: 2.0 mM ammonium acetate buffer as the mobile phases at a flow rate of 1 mL/min. The precursor ion and product ion transition for both analytes and IS were monitored on a triple quadrupole mass spectrometer, operated with selective reaction monitoring in positive ionization mode. The method was validated over a concentration range of 0.5-250.00 ng/mL for baricitinib and methotrexate. Mean extraction recoveries for baricitinib, methotrexate, and IS of 86.8%, 89.4%, and 91.8% were consistent across low, medium, and high QC levels, respectively. Precision and accuracy at low, medium, and high quality control levels were less than 15% across the analytes. Benchtop, wet, freeze-thaw, and long-term stability were evaluated for both of the analytes. The analytical method was applied to support the pharmacokinetic study of simultaneous estimation of baricitinib and methotrexate in Wistar rats. Assay reproducibility was demonstrated by reanalysis of 18 incurred samples.

2.
J Pharm Biomed Anal ; 107: 151-8, 2015 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-25594893

RESUMO

Efficacy assessments using a combination of ibrutinib and lenalidomide necessitate the development of an analytical method for determination of both drugs in plasma with precision. A high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of lenalidomide, ibrutinib, and its active metabolite PCI45227 in rat plasma. Extraction of lenalidomide, ibrutinib, PCI45227 and tolbutamide (internal standard; IS) from 50 µl rat plasma was carried out by liquid-liquid extraction with ethyl acetate:dichloromethane (90:10) ratio. Chromatographic separation of analytes was performed on YMC pack ODS AM (150 mm × 4.6 mm, 5 µm) column under gradient conditions with acetonitrile:0.1% formic acid buffer as the mobile phases at a flow rate of 1 ml/min. Precursor ion and product ion transition for analytes and IS were monitored on a triple quadrupole mass spectrometer, operated in the selective reaction monitoring with positive ionization mode. Method was validated over a concentration range of 0.72-183.20 ng/ml for ibrutinib, 0.76-194.33 ng/ml for PCI-45227 and 1.87-479.16 ng/ml for lenalidomide. Mean extraction recovery for ibrutinib, PCI-45227, lenalidomide and IS of 75.2%, 84.5%, 97.3% and 92.3% were consistent across low, medium, and high QC levels. Precision and accuracy at low, medium and high quality control levels were less than 15% across analytes. Bench top, wet, freeze-thaw and long term stability was evaluated for all the analytes. The analytical method was applied to support a pharmacokinetic study of simultaneous estimation of lenalidomide, ibrutinib, and its active metabolite PCI-45227 in Wistar rat. Assay reproducibility was demonstrated by re-analysis of 18 incurred samples.


Assuntos
Adenina/análogos & derivados , Plasma/química , Pirazóis/sangue , Pirazóis/química , Pirimidinas/sangue , Pirimidinas/química , Talidomida/análogos & derivados , Adenina/sangue , Adenina/química , Animais , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Estabilidade de Medicamentos , Lenalidomida , Extração Líquido-Líquido/métodos , Masculino , Piperidinas , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Talidomida/sangue , Talidomida/química , Tolbutamida/sangue , Tolbutamida/química
3.
J Pharm Biomed Anal ; 94: 125-31, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24561338

RESUMO

Efficacy assessments using a combination of ruxolitinib and nilotinib necessitate the development of a high precision analytical method for determination of both drugs in plasma. A high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of ruxolitinib and nilotinib in rat plasma. Extraction of ruxolitinib, nilotinib and dasatinib (internal standard; IS) from 50µl rat plasma was carried out by protein precipitation with methanol. Chromatographic separation of analytes was performed on YMC pack ODS AM (150mm×4.6mm, 5µm) column under gradient conditions with acetonitrile:2.0mM ammonium acetate buffer as the mobile phase at a flow rate of 1ml/min. Precursor ion and product ion transition for both analytes and IS were monitored on a triple quadrupole mass spectrometer, operated in the selective reaction monitoring with positive ionization mode. Method was validated over a concentration range of 0.16-247ng/ml for ruxolitinib and 0.86-219ng/ml for nilotinib. Mean extraction recovery for ruxolitinib, nilotinib, and IS of 99.6%, 97.6% and 90.3% were consistent across low, medium, and high QC levels. Precision and accuracy at low, medium and high quality control levels were less than 15% across analytes. Bench top, wet, freeze-thaw and long term stability were evaluated for both analytes. The analytical method was applied to support a pharmacokinetic study of simultaneous estimation of ruxolitinib and nilotinib in Wistar rat. Assay reproducibility was demonstrated by re-analysis of 18 incurred samples.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Pirazóis/sangue , Pirazóis/química , Pirimidinas/sangue , Pirimidinas/química , Espectrometria de Massas em Tandem/métodos , Animais , Feminino , Nitrilas , Pirazóis/farmacocinética , Pirimidinas/farmacocinética , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/métodos
4.
Artigo em Inglês | MEDLINE | ID: mdl-24463402

RESUMO

A sensitive and reliable high-performance liquid chromatography-mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous quantification of idelalisib, fludarabine and lenalidomide using tolbutamide as an internal standard. Analytes were recovered by liquid-liquid extraction and separated on a reverse phase C18 column (150mm×4.6mm i.d., 5µm) using methanol:0.1% formic acid buffer (70:30) as mobile phase at a flow rate of 1mL/min in isocratic mode. Selective reaction monitoring was performed using the transitions, i.e. m/z 416.25/176.48, 286.11/154.10, 260.15/149.15, and 271.14/155.06 to quantify idelalisib, fludarabine and lenalidomide and tolbutamide, respectively. The method was validated over the concentration range of 1.15-576.84ng/mL for idelalisib, 0.95-476.25ng/mL for fludarabine and 0.97-486.19ng/mL for lenalidomide. Intra and inter-day accuracy and precision of validated method were within the acceptable limits of <15%. Coefficients of correlation (r(2)) for the calibration curves were >0.998 for all analytes. The method was successfully applied for simultaneous estimation of idelalisib, fludarabine and lenalidomide in a pharmacokinetic study in rats.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Purinas/sangue , Quinazolinonas/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Talidomida/análogos & derivados , Vidarabina/análogos & derivados , Animais , Estabilidade de Medicamentos , Lenalidomida , Masculino , Purinas/química , Purinas/farmacocinética , Quinazolinonas/química , Quinazolinonas/farmacocinética , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/métodos , Talidomida/sangue , Talidomida/química , Talidomida/farmacocinética , Vidarabina/sangue , Vidarabina/química , Vidarabina/farmacocinética
5.
Sci Pharm ; 80(3): 633-46, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23008811

RESUMO

A new method for the simultaneous determination of celecoxib, erlotinib, and its active metabolite desmethyl-erlotinib (OSI-420) in rat plasma, by liquid chromatography/tandem mass spectrometry with positive/negative ion-switching electrospray ionization mode, was developed and validated. Protein precipitation with methanol was selected as the method for preparing the samples. The analytes were separated on a reverse-phase C(18) column (50mm×4.6mm i.d., 3µ) using methanol: 2 mM ammonium acetate buffer, and pH 4.0 as the mobile phase at a flow rate 0.8 mL/min. Sitagliptin and Efervirenz were used as the internal standards for quantification. The determination was carried out on a Theremo Finnigan Quantam ultra triple-quadrupole mass spectrometer, operated in selected reaction monitoring (SRM) mode using the following transitions monitored simultaneously: positive m/z 394.5→278.1 for erlotinib, m/z 380.3→278.1 for desmethyl erlotinib (OSI-420), and negative m/z -380.1→ -316.3 for celecoxib. The limits of quantification (LOQs) were 1.5 ng/mL for Celecoxib, erlotinib, and OSI-420. Within- and between-day accuracy and precision of the validated method were within the acceptable limits of < 15% at all concentrations. The quantitation method was successfully applied for the simultaneous estimation of celecoxib, erlotinib, and desmethyl erlotinib in a pharmacokinetic study in Wistar rats.

6.
J Mass Spectrom ; 47(12): 1612-9, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23280750

RESUMO

A sensitive and reliable high-performance liquid chromatography-mass spectrometry (LC-MS/MS) was developed and validated for simultaneous quantification IC87114, roflumilast (RFM), and its active metabolite roflumilast N-oxide (RFN) using tolbutamide as an internal standard. The analytes were extracted by using liquid-liquid extraction and separated on a reverse phase C(18) column (50 mm × 3 mm i.d., 4.6 µ) using methanol: 2 mM ammonium acetate buffer, pH 4.0 as mobile phase at a flow rate 1 mL/min in gradient mode. Selective reaction monitoring was performed using the transitions m/z 398.3 > 145.9, 403.1 >186.9, 419.1 > 187.0 and 271.1 > 155.0 to quantify quantification IC87114, RFM, RFN and tolbutamide, respectively. The method was validated over the concentration range of 0.1-60 ng.mL(-1) for RFM and RFN and 6 to 2980 ng.mL(-1) for IC87114. Intra- and inter-day accuracy and precision of validated method were within the acceptable limits of <15% at all concentrations. Coefficients of correlation (r(2) ) for the calibration curves were >0.99 for all analytes. The quantitation method was successfully applied for simultaneous estimation of IC87114, RFM and RFN in a pharmacokinetic drug-drug interaction study in Wistar rats.


Assuntos
Adenina/análogos & derivados , Aminopiridinas/sangue , Benzamidas/sangue , Cromatografia Líquida de Alta Pressão/métodos , Quinazolinas/sangue , Espectrometria de Massas em Tandem/métodos , Adenina/sangue , Adenina/química , Adenina/farmacocinética , Aminopiridinas/química , Aminopiridinas/farmacocinética , Animais , Benzamidas/química , Benzamidas/farmacocinética , Ciclopropanos/sangue , Ciclopropanos/química , Ciclopropanos/farmacocinética , Estabilidade de Medicamentos , Modelos Lineares , Masculino , Quinazolinas/química , Quinazolinas/farmacocinética , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...