Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 10(1): 19275, 2020 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-33159150

RESUMO

Circulating compounds such as drugs and nutritional components might adhere to the oxygenator fibers and tubing during ECMO support. This study evaluated the amount of nutritional supplements adsorbed to the ECMO circuit under controlled ex vivo conditions. Six identical ECMO circuits were primed with fresh human whole blood and maintained under physiological conditions at 36 °C for 24 h. A dose of nutritional supplement calculated for a 70 kg patient was added. 150 mL volume was drawn from the priming bag for control samples and kept under similar conditions. Blood samples were obtained at predetermined time points and analyzed for concentrations of vitamins, minerals, lipids, and proteins. Data were analyzed using mixed models with robust standard errors. No significant differences were found between the ECMO circuits and the controls for any of the measured variables: cobalamin, folate, vitamin A, glucose, minerals, HDL cholesterol, LDL cholesterol, total cholesterol, triglycerides or total proteins. There was an initial decrease and then an increase in the concentration of cobalamin and folate. Vitamin A concentrations decreased in both groups over time. There was a decrease in concentration of glucose and an increased concentration of lactate dehydrogenase over time in both groups. There were no significant alterations in the concentrations of nutritional supplements in an ex vivo ECMO circuit compared to control samples. The time span of this study was limited, thus, clinical studies over a longer period of time are needed.


Assuntos
Oxigenação por Membrana Extracorpórea , Adulto , Glicemia/metabolismo , Feminino , Ácido Fólico/sangue , Humanos , L-Lactato Desidrogenase/sangue , Lipídeos/sangue , Masculino , Minerais/sangue , Vitamina A/sangue , Vitamina B 12/sangue
2.
Scand Cardiovasc J ; 43(2): 129-35, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19294579

RESUMO

OBJECTIVES: Phosphorylcholine coated cardiopulmonary bypass (CPB) circuits for children have been available for some years, but conflicting results regarding the inflammatory response have been reported. Accordingly, we aimed to investigate the effect of phosphorylcholine coating on the inflammatory response. DESIGN: Ten coated and nine uncoated pediatric CPB sets were tested in an in vitro CPB circuit model. The inflammatory response was assessed by serial assays of hemoglobin, hematocrit, leukocyte counts, platelet counts, activation of the complement system, activation of platelets measured as beta-thromboglobulin, activation of neutrophils measured as myeloperoxidase, activation of coagulation measured as prothrombin fragments 1+2, assessment of hemolysis measured as lactate dehydrogenase, and a panel of seven cytokines. Samples were obtained at baseline and after 15, 30, 60 and 120 minutes. RESULTS: There were no significant differences between the phosphorylcholine coated circuits and the uncoated circuits for any of the parameters during the observation period, although a potentially beneficial effect on platelets could not be ruled out. CONCLUSIONS: Phosphorylcholine coating of CPB equipment did not exert any beneficial effect on the inflammatory markers monitored.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar/instrumentação , Materiais Revestidos Biocompatíveis , Inflamação/prevenção & controle , Fosforilcolina/farmacologia , Biomarcadores/sangue , Coagulação Sanguínea/efeitos dos fármacos , Ponte Cardiopulmonar/efeitos adversos , Criança , Complexo de Ataque à Membrana do Sistema Complemento/análise , Citocinas/sangue , Desenho de Equipamento , Hematócrito , Hemólise/efeitos dos fármacos , Humanos , Inflamação/sangue , Inflamação/etiologia , Mediadores da Inflamação/sangue , L-Lactato Desidrogenase/sangue , Contagem de Leucócitos , Teste de Materiais , Fragmentos de Peptídeos/análise , Peroxidase/sangue , Contagem de Plaquetas , Protrombina/análise , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...