Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Radiologe ; 58(5): 415-421, 2018 May.
Artigo em Alemão | MEDLINE | ID: mdl-29654331

RESUMO

Injuries of the ligaments and tendons of the ankle and foot are among the most common musculoskeletal injuries. A correct and precise description of the pathology and possible accompanying injuries is essential for treatment planning by trauma and orthopedic surgeons. While X­ray is used to exclude fractures, ultrasound is a very useful tool to assess the ligaments and tendons. For the radiologist, magnetic resonance imaging (MRI) is invaluable regarding the correct assessment of (partial) ruptures, as well as for evaluating accompanying injuries. The aim of the present overview is to provide the most relevant facts for radiologists regarding injuries of ligaments and tendons of the ankle and foot. A description of expected MRI findings and possible pitfalls are presented. For each ligament complex or tendon, we review the anatomy, followed by relevant facts on biomechanics and typical findings in case of injury. The lateral and medial ligament complex, syndesmosis, spring ligament complex, and the Lisfranc ligament are shown in detail. The Achilles tendon and the peroneal tendons are also discussed.


Assuntos
Traumatismos do Pé , Traumatismos dos Tendões , Tornozelo , Articulação do Tornozelo , Humanos , Ligamentos , Ligamentos Articulares , Imageamento por Ressonância Magnética , Radiologistas , Tendões
2.
Eur Radiol ; 27(8): 3443-3451, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27988890

RESUMO

OBJECTIVES: To evaluate the diagnostic accuracy of multidetector CT (MDCT) for detection of lumbar disc herniation with MRI as standard of reference. METHODS: Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered back projection (FBP). Lumbar spine MRI (1.5 T) was performed within 1 month. Signal-to-noise ratios (SNR) of cerebrospinal fluid (CSF), annulus fibrosus (AF) and the spinal cord (SC) were determined for all modalities. Two readers independently rated image quality (IQ), diagnostic confidence and accuracy in the diagnosis of lumbar disc herniation using MRI as standard of reference. Inter-reader correlation was assessed with weighted κ. RESULTS: Sensitivity, specificity, precision and accuracy of MDCT for disc protrusion were 98.8%, 96.5%, 97.1%, 97.8% (disc level), 97.7%, 92.9%, 98.6%, 96.9% (patient level). SNR of IR was significantly higher than FBP. IQ was significantly better in IR owing to visually reduced noise and improved delineation of the discs. κ (>0.90) was excellent for both algorithms. CONCLUSION: MDCT of the lumbar spine yields high diagnostic accuracy for detection of lumbar disc herniation. IR improves image quality so that the provided diagnostic accuracy is principally equivalent to MRI. KEY POINTS: • MDCT is an accurate alternative to MRI in disc herniation diagnosis. • By IR enhanced image quality improves MDCT diagnostic confidence similar to MRI. • Advances in CT technology contribute to improved diagnostic performance in lumbar spine imaging.


Assuntos
Deslocamento do Disco Intervertebral/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Deslocamento do Disco Intervertebral/complicações , Dor Lombar/diagnóstico por imagem , Dor Lombar/etiologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Radiculopatia/diagnóstico por imagem , Radiculopatia/etiologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
3.
AJNR Am J Neuroradiol ; 37(7): 1296-302, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26869467

RESUMO

BACKGROUND AND PURPOSE: The selection of patients for endovascular therapy is an important issue in stroke imaging. The aim of this study was to determine the predictive value of 3 different dynamic CT angiography parameters, occlusion length, collateralization extent, and time delay to maximum enhancement, for latest generation of stent retriever thrombectomy recanalization outcomes in patients with acute ischemic stroke. MATERIALS AND METHODS: In this study, subjects were selected from an initial cohort of 2059 consecutive patients who had undergone multiparametric CT, including whole-brain CT perfusion. We included all patients with a complete occlusion of the M1 segment of the MCA or the carotid T and subsequent intra-arterial stent retriever thrombectomy. Dynamic CT angiography was reconstructed from whole-brain CT perfusion raw datasets. Angiographic outcome was scored by using the modified TICI scale; and clinical outcome, by using the modified Rankin Scale. Logistic regression analyses were performed to determine independent predictors of a favorable angiographic (mTICI = 3) and clinical outcome (mRS ≤2). RESULTS: Sixty-nine patients (mean age, 68 ± 14 years; 46% men) were included for statistical analysis. In the regression analysis, a short occlusion length was an independent predictor of favorable angiographic outcome (OR, 0.41; P < .05). Both collateralization grade (OR, 1.00; P > .05) and time delay to peak enhancement (OR, 0.90; P > .05) failed to predict a favorable angiographic outcome. None of the dynamic CT angiography predictors were significantly associated with clinical outcome on discharge (OR, 0.664-1.011; P = .330-.953) or at 90 days (OR, 0.779-1.016; P = .130-.845). CONCLUSIONS: A short occlusion length as determined by dynamic CT angiography is an independent predictor of a favorable angiographic outcome of stent retriever thrombectomy in patients with ischemic stroke.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Trombectomia/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Stents , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
4.
Int J Comput Assist Radiol Surg ; 11(12): 2199-2205, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26811078

RESUMO

PURPOSE: To evaluate feasibility of automatic software-based path proposals for CT-guided percutaneous biopsies. METHODS: Thirty-three patients (60 [Formula: see text] 12 years) referred for CT-guided biopsy of focal liver lesions were consecutively included. Pre-interventional CT and dedicated software (FraunhoferMeVis Pathfinder) were used for (semi)automatic segmentation of relevant structures. The software subsequently generated three path proposals in downward quality for CT-guided biopsy. Proposed needle paths were compared with consensus proposal of two experts (comparable, less suitable, not feasible). In case of comparable results, equivalent approach to software-based path proposal was used. Quality of segmentation process was evaluated (Likert scale, 1 [Formula: see text] best, 6 [Formula: see text] worst), and time for processing was registered. RESULTS: All biopsies were performed successfully without complications. In 91 % one of the three automatic path proposals was rated comparable to experts' proposal. None of the first proposals was rated not feasible, and 76 % were rated comparable to the experts' proposal. 7 % automatic path proposals were rated not feasible, all being second choice ([Formula: see text]) or third choice ([Formula: see text]). In 79 %, segmentation at least was good. Average total time for establishing automatic path proposal was 42 [Formula: see text] 9 s. CONCLUSION: Automatic software-based path proposal for CT-guided liver biopsies in the majority provides path proposals that are easy to establish and comparable to experts' insertion trajectories.


Assuntos
Biópsia Guiada por Imagem , Fígado/patologia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/métodos , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Software , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
5.
AJNR Am J Neuroradiol ; 36(3): 488-94, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25523589

RESUMO

BACKGROUND AND PURPOSE: Collateral blood flow is an important prognostic marker in the acute stroke situation but approaches for assessment vary widely. Our aim was to compare strategies of collateral blood flow assessment in dynamic and conventional CTA in their ability to predict the follow-up infarction volume. MATERIALS AND METHODS: We retrospectively included all patients with an M1 occlusion from an existing cohort of 1912 consecutive patients who underwent initial multimodal stroke CT and follow-up MR imaging or nonenhanced CT. Collateralization was assessed in both conventional CT angiography and dynamic CT angiography by using 3 different collateral grading scores and segmentation of the volume of hypoattenuation. Arterial, arteriovenous, and venous phases were reconstructed for dynamic CT angiography, and all collateral scores and the volume of hypoattenuation were individually assessed for all phases. Different grading systems were compared by using the Bayesian information criterion calculated for multivariate regression analyses (Bayesian information criterion difference = 2-6, "positive"; Bayesian information criterion difference = 6-10, "strong"; Bayesian information criterion difference = >10, "very strong"). RESULTS: One hundred thirty-six patients (mean age, 70.4 years; male sex, 41.2%) were included. In the multivariate analysis, models containing the volume of hypoattenuation showed a significantly better model fit than models containing any of the 3 collateral grading scores in conventional CT angiography (Bayesian information criterion difference = >10) and dynamic CT angiography (Bayesian information criterion difference = >10). All grading systems showed the best model fit in the arteriovenous phase. For the volume of hypoattenuation, model fit was significantly higher for models containing the volume of hypoattenuation as assessed in the arteriovenous phase of dynamic CT angiography compared with the venous phase (Bayesian information criterion difference = 6.2) and the arterial phase of dynamic CT angiography (Bayesian information criterion difference = >10) and in comparison with conventional CT angiography (Bayesian information criterion difference = >10). CONCLUSIONS: The use of dynamic CT angiography within the arteriovenous phase by using quantification of the volume of hypoattenuation is the superior technique for assessment of collateralization among the tested approaches.


Assuntos
Isquemia Encefálica/fisiopatologia , Infarto Cerebral/fisiopatologia , Circulação Cerebrovascular/fisiologia , Circulação Colateral/fisiologia , Acidente Vascular Cerebral/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Teorema de Bayes , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
6.
Rofo ; 186(2): 151-6, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23975878

RESUMO

OBJECTIVES: The aim of the study was to determine whether automated quantification of pulmonary perfused blood volume (PBV) in dual-energy computed tomography pulmonary angiography (DE-CTPA) can be used to assess the severity of chronic thromboembolic pulmonary hypertension (CTEPH). METHODS: Automated quantification of PBV was performed in 25 consecutive CTEPH patients undergoing DE-CTPA. PBV values were correlated with cardiac index and pulmonary vascular resistance quantified by right heart catheterization and walking distance in the 6-minute walk test using Pearson's correlation coefficient and multivariate linear regression analysis to control for age and gender. RESULTS: DE-CTPA derived PBV values inversely correlated with systolic (r = -0.64, p = 0.001) and mean (r = -0.57, p = 0.004) pulmonary arterial pressure. There was a trend for PBV values to inversely correlate with pulmonary vascular resistance (r = -0.20, p = 0.35). No significant correlation was found between PBV values and cardiac index or 6-minute walking distance. These correlations were confirmed to be independent of age and gender on multivariate linear regression analysis. CONCLUSION: DE-CTPA can be used for an automated quantification of pulmonary PBV in chronic thromboembolic pulmonary hypertension. PBV values correlate inversely with systolic and mean pulmonary arterial pressure and can thus be used to estimate the severity of pulmonary hypertension in these patients. Citation Format: • Meinel FG, Graef A, Thierfelder KM et al. Automated Quantification of Pulmonary Perfused Blood Volume by Dual-Energy CTPA in Chronic Thromboembolic Pulmonary Hypertension. Fortschr Röntgenstr 2014; 186: 151 - 156.


Assuntos
Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/fisiopatologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Angiografia , Volume Sanguíneo , Determinação do Volume Sanguíneo/métodos , Doença Crônica , Feminino , Humanos , Hipertensão Pulmonar/etiologia , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/complicações , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Gesundheitswesen ; 71(5): 306-12, 2009 May.
Artigo em Alemão | MEDLINE | ID: mdl-19288425

RESUMO

BACKGROUND: Since 1 January 2004, inpatient treatment services in German hospitals have been reimbursed using a prospective payment method based on diagnosis-related groups (DRGs) rather than daily rates. The aim of the payment system reform was to decrease the length of inpatient stays and reduce overall healthcare expenditure, the latter of which had increased markedly during previous decades. OBJECTIVE: The primary objective of our study was to analyse and describe the health-economic consequences of implementing a DRG-based system of prospective payment in Germany. METHODS: A systematic search of the literature was performed on MEDLINE. Inclusion criteria were a focus on health economic variables from the German perspective and a publication date after 1 January 2004. The search was supplemented by a manual review of references, as well as internet-based hand search. The main health-economic conclusions were subsequently extracted from all of the included studies. RESULTS: A total of 19 quantitative and qualitative studies were included. There were substantial differences between them in terms of medical focus and hospital characteristics. The most common health-economic variables analysed were revenue generated by patient treatment, and length of inpatient stay. As expected, both variables showed a decreasing trend following the introduction of DRGs. The included studies also investigated the development of case numbers, the proportion of outpatient services provided, the number of diagnoses per case, and the homogeneity of case groups. For these variables, the studies showed a wide range of results. CONCLUSION: Similar to the experience with DRGs in many other countries, the introduction of DRGs in Germany has led to a reduction in the length of inpatient stay and a decrease in hospital revenues. The effects on other health-economic parameters are inconsistent. Additional studies in this area are needed.


Assuntos
Honorários e Preços/estatística & dados numéricos , Custos de Cuidados de Saúde/estatística & dados numéricos , Modelos Econômicos , Discrepância de GDH/economia , Discrepância de GDH/estatística & dados numéricos , Sistema de Pagamento Prospectivo/economia , Sistema de Pagamento Prospectivo/estatística & dados numéricos , Alemanha
8.
Z Kardiol ; 72(3): 187-92, 1983 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-6858298

RESUMO

Preliminary results concerning the occlusion of experimental atrial-septal defects (ASDII) of the secundum type are reported. An occlusion element was inserted transvenously and its passage across the atrial-septal defect was controlled by open-heart surgery in dogs. Subsequently, the defect was occluded using a single-piece element. In all 5 surgical experiments the occlusion was possible without dislocation or embolism of the element during an atrial stimulation of the heart for more than 1 hour. In additional experiments without open-heart surgery, atrial-septal defects were produced in 7 dogs by transseptal punction and perforation under X-ray control. The atrial-septal defects could be closed for a short time in 2 dogs. In 1 of the 2 dogs the element embolized into the right pulmonary artery, and in the other into the abdominal aorta. Transvenous occlusion of experimental atrial-septal defects is possible, but more experimental work is necessary with respect to the technical problems.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/cirurgia , Animais , Prótese Vascular , Cães , Comunicação Interatrial/diagnóstico por imagem , Radiografia
9.
Radiologe ; 20(10): 494-9, 1980 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-7444042

RESUMO

Percutaneous transluminal angioplasty in renal artery obstructions was performed in 10 cases. In 7 patients the hypertension was successfully treated and in one patient renal function could be restored. The procedure can be applied in atherosclerotic and fibromuscular stenoses as well as in stenosis of kidney grafts. In our opinion catheter dilatation should be prefered to vascular surgery, because it is efficient and inexpensive and has a low risk. Operation should be reserved to cases untreatable with angioplasty.


Assuntos
Cateterismo , Hipertensão Renal/terapia , Hipertensão Renovascular/terapia , Adulto , Cateterismo/métodos , Dilatação/instrumentação , Humanos , Pessoa de Meia-Idade , Obstrução da Artéria Renal/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...