Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Chem Res ; 24(4): 1480-1486, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25750500

RESUMO

18F-Mefway (N-{2-[4-(2'-methoxyphenyl)piperazinyl]ethyl}-N-(2-pyridyl)-N-(4'-18F-fluoro-methylcyclohexane)carboxamide) was developed and evaluated for use as a PET ligand for imaging 5-HT1A receptors. Ongoing studies of 18F-Mefway have shown it to be an effective PET radiotracer. We have synthesized isomers of Mefway by changing the position of the methyl-group in attempts to evaluate stability for imaging purposes. 2-Methyl-, 3-methyl-, and 4-methyl-cyclohexane-1-carboxylic acids and 3-carbomethoxy-, 4-carbomethoxycyclohexane-1-carboxylic acids were coupled with WAY-100634 to provide the methylcyclohexyl derivatives (2-, 3- and 4-methyl). Mefway and 3-Mefway analogs were prepared by reduction of carbomethoxy-derivatives followed by fluorination. In vitro binding affinities for the methylated derivatives in rat brain homogenates was found to be 10.4 nM (2-methyl), 77 nM (3-methyl) and 21.5 nM (4-methyl). Binding affinity of 3-Mefway and 4-Mefway was found to be 17.4 nM and 6.26 nM, respectively. Our results suggest that 3-methyl/3-fluoromethyl substituent has approx. 3-fold lower affinities compared to the 4-methyl/4-fluoromethyl substituent.

2.
Am J Nucl Med Mol Imaging ; 4(5): 483-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25143866

RESUMO

4-trans-[(18)F]Mefway is a PET radiotracer with high affinity for 5-HT1A receptors. Our preliminary work indicated the positional isomer, 3-[(18)F]mefway, would be suitable for PET imaging of 5-HT1A receptors. We now compare the in vivo behaviour of 3-mefway with 4-mefway to evaluate 3-[(18)F]mefway as a potential 5-HT1A PET radiotracer. Two male rhesus macaques were given bolus injections of both 3- and 4-trans-[(18)F]mefway in separate experiments. 90 minute dynamic PET scans were acquired. TACs were extracted in the mesial temporal lobe (MTL) and caudal anterior cingulate gyrus (cACg). The cerebellum (CB) was used as a reference region. In vivo behavior of the radiotracers in the CB was compared based upon the ratio of normalized PET uptake for 3- and 4-trans-[(18)F]mefway. Specific binding was compared by examining MTL/CB and cACg/CB ratios. The subject-averaged ratio of 3-[(18)F]mefway to 4-trans-[(18)F]mefway in the cerebellum was 0.96 for 60-90 minutes. MTL/CB reached plateaus of ~2.7 and ~6 by 40 minutes and 90 minutes for 3- and 4-trans-[(18)F]mefway, respectively. cACg/CB reached plateaus of ~2.5 and ~6 by 40 minutes and 70 minutes for 3- and 4-trans-[(18)F]mefway, respectively. The short pseudoequilibration times and sufficient uptake of 3-[(18)F]mefway may be useful in studies requiring short scan times. Furthermore, the similar nondisplaceable clearance in the CB to 4-trans-[(18)F]mefway suggests the lower BPND of 3-[(18)F]mefway is due to a lower affinity. The lower affinity of 3-[(18)F]mefway may make it useful for measuring changes in endogenous 5-HT levels, however, this remains to be ascertained.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...