1.
Anal Chem ; 95(48): 17868-17877, 2023 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-38050672

RESUMO

The online coupling of size exclusion chromatography (SEC) to capillary enhanced Raman spectroscopy (CERS) based on a liquid core waveguide (LCW) flow cell was applied for the first time to assess the higher-order structure of different proteins. This setup allows recording of Raman spectra of the monomeric protein within complex mixtures, since SEC enables the separation of the monomeric protein from matrix components such as excipients of a biopharmaceutical product and higher molecular weight species (e.g., aggregates). The acquired Raman spectra were used for structural elucidation of well characterized proteins such as bovine serum albumin, hen egg white lysozyme, and ß-lactoglobulin and of the monoclonal antibody rituximab in a medicinal product. Additionally, the CERS detection of the disaccharide sucrose, which is used as a stabilizing excipient, was quantified to achieve a limit of detection (LOD) of 120 µg and a limit of quantification (LOQ) of 363 µg injected on the column.


Assuntos
Produtos Biológicos , Análise Espectral Raman , Cromatografia em Gel , Excipientes/análise , Soroalbumina Bovina
2.
J Sep Sci ; 46(14): e2300076, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37287327

RESUMO

The polycyclic aromatic hydrocarbon concentration in plastic products is regulated in (European Union) No. 1272/2013. However, this only covers the end products and not intermediate substances. Therefore, a generic method was developed to analyze the polycyclic aromatic hydrocarbons listed by the Environmental Protection Agency and the European Union. This method is based on direct large volume injection from solutions of plastic additives followed by liquid chromatography coupled to fluorescence detection. The additives Irganox 1010, ureido methacrylate, and cetyl methacrylate 1618F were used as examples for method development. Two serially coupled columns allowed the matrix to be removed on the first column and the analytes to be separated on the second column. The columns were connected by an intermediate valve. The valve allowed the matrix to be diverted after the first column and water to be dosed upstream of the second column via an additional pump. This allowed samples in aqueous or organic media to be focused at the column head. An injection volume of 100 µl and online aqueous dilution of 1:3 led to a limit of detection below 1 ng/ml for 15 polycyclic aromatic hydrocarbons. Moreover, concentrations between 1.6 and 10.3 ng/ml were found in the three plastic additives.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...