Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Chirurgie (Heidelb) ; 94(8): 669-674, 2023 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-37142798

RESUMO

The liver is involved in about 20% of cases of blunt abdominal trauma. The management of liver trauma has changed significantly in the past three decades towards conservative treatment. Up to 80% of all liver trauma patients can now be successfully treated by nonoperative management. Decisive for this is the adequate screening and assessment of the patient and the injury pattern as well as the provision of the appropriate infrastructure. Hemodynamically unstable patients require immediate exploratory surgery. In hemodynamically stable patients, a contrast-enhanced computed tomography (CT) should be performed. If active bleeding is detected angiographic imaging and embolization should be performed to stop the bleeding. Even after initially successful conservative management of liver trauma, subsequent complications can occur that make surgical inpatient treatment necessary.


Assuntos
Traumatismos Abdominais , Embolização Terapêutica , Ferimentos não Penetrantes , Humanos , Embolização Terapêutica/métodos , Fígado/diagnóstico por imagem , Fígado/lesões , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/terapia , Traumatismos Abdominais/diagnóstico por imagem , Traumatismos Abdominais/terapia , Tomografia Computadorizada por Raios X
2.
Langenbecks Arch Surg ; 408(1): 8, 2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36602631

RESUMO

PURPOSE: Autosomal dominant polycystic kidney disease (ADPKD) is a common hereditary disorder and accounts for 5-10% of all cases of kidney failure. 50% of ADPKD patients reach kidney failure by the age of 58 years requiring dialysis or transplantation. Nephrectomy is performed in up to 20% of patients due to compressive symptoms, renal-related complications or in preparation for kidney transplantation. However, due to the large kidney size in ADPKD, nephrectomy can come with a considerable burden. Here we evaluate our institution's experience of laparoscopic nephrectomy (LN) as an alternative to open nephrectomy (ON) for ADPKD patients. MATERIALS AND METHODS: We report the results of the first 12 consecutive LN for ADPKD from August 2020 to August 2021 in our institution. These results were compared with the 12 most recent performed ON for ADPKD at the same institution (09/2017 to 07/2020). Intra- and postoperative parameters were collected and analyzed. Health related quality of life (HRQoL) was assessed using the SF36 questionnaire. RESULTS: Age, sex, and median preoperative kidney volumes were not significantly different between the two analyzed groups. Intraoperative estimated blood loss was significantly less in the laparoscopic group (33 ml (0-200 ml)) in comparison to the open group (186 ml (0-800 ml)) and postoperative need for blood transfusion was significantly reduced in the laparoscopic group (p = 0.0462). Operative time was significantly longer if LN was performed (158 min (85-227 min)) compared to the open procedure (107 min (56-174 min)) (p = 0.0079). In both groups one postoperative complication Clavien Dindo ≥ 3 occurred with the need of revision surgery. SF36 HRQol questionnaire revealed excellent postoperative quality of life after LN. CONCLUSION: LN in ADPKD patients is a safe and effective operative procedure independent of kidney size with excellent postoperative outcomes and benefits of minimally invasive surgery. Compared with the open procedure patients profit from significantly less need for transfusion with comparable postoperative complication rates. However significant longer operation times need to be taken in account.


Assuntos
Laparoscopia , Rim Policístico Autossômico Dominante , Insuficiência Renal , Humanos , Pessoa de Meia-Idade , Rim Policístico Autossômico Dominante/cirurgia , Qualidade de Vida , Estudos Retrospectivos , Nefrectomia/métodos , Laparoscopia/métodos , Complicações Pós-Operatórias/etiologia , Insuficiência Renal/complicações , Insuficiência Renal/cirurgia , Perda Sanguínea Cirúrgica , Rim
3.
Int J Surg ; 102: 106643, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35490950

RESUMO

AIMS: Opportunity cost (OC) analysis is key when evaluating surgical techniques. Operating room (OR) time is one potential source of OC in laparoscopic surgery. This study quantifies differences in OR time between 3D- and 2D-imaging technology in laparoscopic surgery, translates these into OC and models the economic impact in real-world hospitals. METHODS: First a systematically performed literature review and meta-analysis were conducted. Then, methods to translate OR time savings into OC were theorised and a budget impact model was created. After that, the potential time savings of real-world hospital case mixes were extrapolated. Finally, the opportunity costs of not using 3D-imaging in laparoscopic surgery were evaluated. RESULTS: Average OR time saving per laparoscopic procedure was -19.4 min (-24.3; -14.5) (-14%) in favour of 3D. The Budget Impact Model demonstrated an economic impact of using 3D-laparoscopy instead of 2D laparoscopy, ranging from £183,045-£866,316 in the British and 73,049€-437,829€ in German hospitals, modelling a mixture of cost savings and performing additional procedures (earning additional revenue). CONCLUSION: The OC analysis revealed significant economic benefits of introducing 3D-imaging technology in laparoscopic surgery, on the basis that average procedure time is reduced. Utilising the saved OR time to perform additional procedures was the biggest driver of OC. Hospital case mix and procedure volume indicated the magnitude of the OC.


Assuntos
Laparoscopia , Salas Cirúrgicas , Análise Custo-Benefício , Alemanha , Hospitais , Humanos , Laparoscopia/métodos , Tecnologia , Reino Unido
4.
Surg Endosc ; 35(12): 6763-6769, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33289054

RESUMO

BACKGROUND: In order to efficiently perform laparoscopic microwave ablation of liver tumours precise positioning of the ablation probe is mandatory. This study evaluates the precision and ablation accuracy using the innovative laparoscopic stereotactic navigation system CAS-One-SPOT in comparison to 2d ultrasound guided laparoscopic ablation procedures. METHODS: In a pig liver ablation model four surgeons, experienced (n = 2) and inexperienced (n = 2) in laparoscopic ablation procedures, were randomized for 2d ultrasound guided laparoscopic or stereotactic navigated laparoscopic ablation procedures. Each surgeon performed a total of 20 ablations. Total attempts of needle placements, time from tumor localization till beginning of ablation and ablation accuracy were analyzed. RESULTS: The use of the laparoscopic stereotactic navigation system led to a significant reduction in total attempts of needle placement. The experienced group of surgeons reduced the mean number of attempts from 2.75 ± 2.291 in the 2d ultrasound guided ablation group to 1.45 ± 1.191 (p = 0.0302) attempts in the stereotactic navigation group. Comparable results could be observed in the inexperienced group with a reduction of 2.5 ± 1.50 to 1.15 ± 0.489 (p = 0.0005). This was accompanied by a significant time saving from 101.3 ± 112.1 s to 48.75 ± 27.76 s (p = 0.0491) in the experienced and 165.5 ± 98.9 s to 66.75 ± 21.96 s (p < 0.0001) in the inexperienced surgeon group. The accuracy of the ablation process was hereby not impaired as postinterventional sectioning of the ablation zone revealed. CONCLUSION: The use of a stereotactic navigation system for laparoscopic microwave ablation procedures of liver tumors significantly reduces the attempts and time of predicted correct needle placement for novices and experienced surgeons without impairing the accuracy of the ablation procedure.


Assuntos
Ablação por Cateter , Laparoscopia , Neoplasias Hepáticas , Cirurgia Assistida por Computador , Animais , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Suínos
5.
Chirurg ; 91(1): 18-22, 2020 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-31712829

RESUMO

Bile duct injuries can occur after abdominal trauma, postoperatively after cholecystectomy, liver resection or liver transplantation and also as a complication of endoscopic retrograde cholangiopancreatography (ERCP). The clinical appearance of bile duct injuries is highly variable and depends primarily on the underlying cause. In addition to the high perioperative morbidity, following successful initial complication management, bile duct injuries can lead to significant long-term complications. The treatment requires close interdisciplinary cooperation between surgery, interventional gastroenterology and interventional radiology. The treatment of bile duct injuries depends primarily on the time of diagnosis (intraoperative/postoperative) as well as the extent of the injury and is discussed in this review.


Assuntos
Traumatismos Abdominais , Ductos Biliares , Colecistectomia Laparoscópica , Transplante de Fígado , Traumatismos Abdominais/cirurgia , Ductos Biliares/lesões , Ductos Biliares/cirurgia , Colangiopancreatografia Retrógrada Endoscópica , Colecistectomia , Humanos
6.
Eur Arch Otorhinolaryngol ; 273(8): 2231-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26993656

RESUMO

Malnutrition is considered as an independent risk factor for morbidity, mortality and a prolonged hospital stay for in-hospital patients. While most available data on the impact of malnutrition on health-related and financial implications refer to gastroenterologic or abdominal surgery patients, little is known about the impact of malnutrition on Ear Nose Throat (ENT)/head and neck surgery patients. The objective of this study was to investigate the impact of malnutrition on morbidity and length of hospital stay in an elective ENT/head and neck surgery patient cohort. The study was performed as a single-center, prospective cohort study at a tertiary referral centre. Nutritional risk at admission was assessed using the NRS-2002 screening tool. Multivariate regression models were used to determine independent risk factors for complications and a prolonged hospitalization. Three hundred fifty one participants were included in the study. A malignant disease was found in 62 participants (17.7 %). 62 patients (17.7 %) were at a moderate to severe risk of malnutrition. A bad general health condition and complications during hospital stay could be identified as independent risk factors for a prolonged hospitalization. Patients with a malignant tumor showed a more than fourfold higher risk of developing at least one complication. Malnutrition, however, was not statistically associated with a higher complication rate or a prolonged hospital stay. Our data suggests that malnutrition does not seem to play such an important role as a risk factor for complications and a prolonged hospital stay in ENT patients as it does in other disciplines like abdominal surgery or gastroenterology.


Assuntos
Procedimentos Cirúrgicos Eletivos/efeitos adversos , Tempo de Internação , Desnutrição/complicações , Procedimentos Cirúrgicos Otorrinolaringológicos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Adulto , Fatores Etários , Idoso , Análise de Variância , Feminino , Humanos , Masculino , Desnutrição/diagnóstico , Pessoa de Meia-Idade , Morbidade , Estado Nutricional , Estudos Prospectivos , Fatores de Risco , Adulto Jovem
7.
Langenbecks Arch Surg ; 400(8): 979-83, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26566989

RESUMO

INTRODUCTION: Ascites is a common complication of liver cirrhosis and represents the main cause of hospitalization among patients with cirrhosis. First-line therapy for those patients is the use of diuretics and dietary sodium restriction. However, 10 % of patients per year become therapy refractory to diuretic treatment with the need of repeated high-volume paracentesis or transjugular intrahepatic portosystemic shunt (TIPS). For these patients, an automated pump system (Alfapump/Sequana Medical) was developed. Here, we describe our single-center experience of ten consecutively implanted pump systems. PATIENTS AND METHODS: Between 08/13 and 11/14, ten Alfapump systems were implanted in patients with refractory ascites all suffering from liver cirrhosis. Those patients were treated as a bridge to transplant (4/10) or as an end-stage therapy (6/10). Median follow-up was 165 days (23-379 days). RESULTS: Postimplant, the need of paracentesis could be markedly reduced to a mean of 0.45 (0-4/month) per month. In eight patients, paracentesis was not needed after implantation of the pump system. The median daily output volume was 1000 ml/day (450-2000 ml/day). Prerenal insufficiency was a recurrent complication in the postoperative period. DISCUSSION: The Alfapump system is a useful system in the treatment of patients suffering from therapy refractory ascites. However, due to the high level of comorbidities, careful patient selection and postoperative monitoring are required.


Assuntos
Ascite/etiologia , Ascite/terapia , Cirrose Hepática/complicações , Próteses e Implantes , Feminino , Humanos , Testes de Função Renal , Tempo de Internação/estatística & dados numéricos , Testes de Função Hepática , Masculino , Duração da Cirurgia , Paracentese , Seleção de Pacientes , Derivação Portossistêmica Transjugular Intra-Hepática , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento
8.
Scand J Immunol ; 82(2): 102-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25970072

RESUMO

The rejection process remains the key unsolved issue after transplantation of disparate tissue. The CC chemokine monocyte chemoattractant protein-1 (MCP-1/CCL2) has been reported to be involved in the process of alloimmune interaction. Spiegelmers are l-oligonucleotides that can be designed to bind to pharmacologically relevant target molecules. Here, we tested a high-affinity Spiegelmer-based MCP-1 inhibitor (mNOX-E36) in an allogeneic heart transplant model. Fully vascularized allogeneic heterotopic heart transplantations from BALB/c to C57BL/6 mice were performed. Mice were either treated with the anti-MCP-1-Spiegelmer (mNOX-E36) in monotherapy or in combination with subtherapeutic doses of cyclosporine A (CsA) (10 mg/kgBW/day) for 10 days. Controls received equivalent doses of a non-functional Spiegelmer (revmNOX-E36). Graft survival of allogeneic heart transplants was slightly but significantly prolonged under mNOX-E36 monotherapy (median graft survival 10 day ± 0.7) compared to revmNOX-E36 (median graft survival 7 day ± 0.3; P = 0.001). A synergistic beneficial effect could be seen when mNOX-E36 was administered in combination with subtherapeutic doses of CsA (18 day ± 2.8 versus 7 day ± 0.3; P < 0.0001). Levels of inflammatory cytokines and 'alarmins' were significantly reduced, and the number of F4/80(+) cells was lower under combination therapy (1.8% ± 1.3%; versus 14.6% ± 4.4%; P = 0.0002). This novel inhibitor of the MCP-1/CCR2 axis (mNOX-E36), which has already proven efficacy and tolerability in early clinical trials, alleviates acute rejection processes in allogeneic transplantation especially when combined with subtherapeutic doses of CsA. Thus, mNOX-E36 may have potential as an adjunct immunomodulatory agent.


Assuntos
Aptâmeros de Nucleotídeos/uso terapêutico , Quimiocina CCL2/antagonistas & inibidores , Sobrevivência de Enxerto/efeitos dos fármacos , Imunossupressores/uso terapêutico , Receptores CCR2/antagonistas & inibidores , Animais , Ciclosporina/uso terapêutico , Rejeição de Enxerto/imunologia , Transplante de Coração , Terapia de Imunossupressão/métodos , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Transplante Homólogo
9.
J Reprod Fertil ; 112(1): 175-84, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9538343

RESUMO

Twenty-four crossbred primiparous sows were used to investigate the influence of insulin administration after weaning on the intrafollicular insulin-like growth factor i (IGF-I) system. Sows received 0.4 i.u. insulin kg-1 bodyweight or an equivalent volume of saline for 3 days (n = 5 insulin; n = 4 saline) or 5 days (n = 5 insulin; n = 6 saline) after weaning or served as untreated controls on day 1 (n = 4). The number and diameters of ovarian follicles were recorded, and fluid was aspirated from the 20 largest follicles for determination of oestradiol and IGF-I by radioimmunoassay and of insulin-like growth factor-binding proteins (IGFBPs) by western ligand blotting. The walls of the follicles were collected for mRNA analysis by RNase protection assay or granulosa cells were collected for estimation of apoptosis by flow cytometry. Insulin treatment resulted in smaller diameters of all follicles (P < 0.05) and tended (P < 0.07) to increase the number of follicles available on day 5 compared with saline-treated animals (19.8 versus 17.8). The concentration of oestradiol in follicular fluid from large (7-10 mm) follicles on days 3 and 5 was reduced (treatment by size class interaction; P < 0.05) by insulin treatment. Insulin also reduced intrafollicular concentrations of IGF-I at days 3 and 5 after weaning (treatment by day interaction; P < 0.02) while the amounts of IGFBP-3 and IGFBPs of molecular mass 30 and 22 kDa decreased from day 3 to day 5 in saline-treated animals only (treatment by day interaction; P < 0.05). Gene expression for IGF-I increased in saline-treated animals but decreased fourfold in insulin-treated sows from day 3 to day 5 (treatment by day interaction; P < 0.002). Gene expression for IGFBP-d decreased (P < 0.04) from day 3 to day 5, while expression of IGFBP-2 was unaffected by treatment or day. Overall, insulin influenced the IGF-I system in a manner consistent with slowing follicular growth and possibly allowed more follicles to become available for ovulation.


Assuntos
Fator de Crescimento Insulin-Like I/metabolismo , Insulina/farmacologia , Folículo Ovariano/fisiologia , Suínos/metabolismo , Animais , Apoptose , Estradiol/análise , Estradiol/metabolismo , Feminino , Citometria de Fluxo , Líquido Folicular/química , Líquido Folicular/metabolismo , Proteína 3 de Ligação a Fator de Crescimento Semelhante à Insulina/análise , Proteína 3 de Ligação a Fator de Crescimento Semelhante à Insulina/genética , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/análise , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/genética , Fator de Crescimento Insulin-Like I/análise , Fator de Crescimento Insulin-Like I/genética , Folículo Ovariano/efeitos dos fármacos , RNA Mensageiro/análise , Desmame
12.
Int J Gynaecol Obstet ; 16(4): 333-8, 1978.
Artigo em Inglês | MEDLINE | ID: mdl-35399

RESUMO

In 1975, a two-year study designed to test the new Ypsilon IUD was initiated by the Family Planning Center (Department of Obstetrics and Gynecology, Medical University), Debrecen, Hungary. From November 1975 through September 1976, Ypsilon-Y intrauterine devices (IUDs) were inserted in 300 women who had not previously used IUDs. The control group consisted of 300 Lippes Loop D users, all of whom were also first-time IUD users. The selection was made by randomization. After one year, the relevant rates (pregnancy, expulsion, medical removals) for the study group were: 3.9, 10.4 and 7.8, respectively. The corresponding values for the Lippes Loop D group were: 2.8, 5.7 and 7.8 per 100 women. Although the pregnancy rate for the control population was lower, the difference was not statistically significant. The frequency of expulsion in the Ypsilon-Y users was higher than that of the Lippes Loop D acceptors, but the difference was not statistically significant at the 0.05 level. The medical removal rates were almost the same in both groups. The total number of bleeding, pain and dysmenorrheic complaints in the two groups were also compared and showed that the Ypsilon-Y users did not report complaints as often as did the women wearing the Lippes Loop D. The difference was statistically significant. The relevant termination rates of the Ypsilon-Y were higher than those for the Lippes Loop D; however, the lower frequency of complaints in the study group suggests that the shape of the Y may be more suitable for the uterine cavity than the Loop D.


Assuntos
Dispositivos Intrauterinos , Feminino , Humanos , Expulsão de Dispositivo Intrauterino , Dispositivos Intrauterinos/efeitos adversos , Elastômeros de Silicone , Aço Inoxidável
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...