Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Cardiol ; 18(2): 259-66, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21161704

RESUMO

BACKGROUND: PET reconstruction incorporating spatially variant 3D Point Spread Function (PSF) improves contrast and image resolution. "Cardiac Motion Frozen" (CMF) processing eliminates the influence of cardiac motion in static summed images. We have evaluated the combined use of CMF- and PSF-based reconstruction for high-resolution cardiac PET. METHODS: Static and 16-bin ECG-gated images of 20 patients referred for (18)F-FDG myocardial viability scans were obtained on a Siemens Biograph-64. CMF was applied to the gated images reconstructed with PSF. Myocardium to blood contrast, maximum left ventricle (LV) counts to defect contrast, contrast-to-noise (CNR) and wall thickness with standard reconstruction (2D-AWOSEM), PSF, ED-gated PSF, and CMF-PSF were compared. RESULTS: The measured wall thickness was 18.9 ± 5.2 mm for 2D-AWOSEM, 16.6 ± 4.5 mm for PSF, and 13.8 ± 3.9 mm for CMF-PSF reconstructed images (all P < .05). The CMF-PSF myocardium to blood and maximum LV counts to defect contrasts (5.7 ± 2.7, 10.0 ± 5.7) were higher than for 2D-AWOSEM (3.5 ± 1.4, 6.5 ± 3.1) and for PSF (3.9 ± 1.7, 7.7 ± 3.7) (CMF vs all other, P < .05). The CNR for CMF-PSF (26.3 ± 17.5) was comparable to PSF (29.1 ± 18.3), but higher than for ED-gated dataset (13.7 ± 8.8, P < .05). CONCLUSION: Combined CMF-PSF reconstruction increased myocardium to blood contrast, maximum LV counts to defect contrast and maintained equivalent noise when compared to static summed 2D-AWOSEM and PSF reconstruction.


Assuntos
Fluordesoxiglucose F18 , Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
2.
J Nucl Cardiol ; 17(3): 414-26, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20151238

RESUMO

BACKGROUND: We aimed to determine in phantom and cardiac clinical studies the impact of a new high-resolution PET image reconstruction. METHODS: A phantom with cardiac insert filled with (18)F, 14 (18)F-FDG viability studies and 15 (82)Rb perfusion studies were acquired on a Siemens Biograph-64 (4-ring). The data were reconstructed with 2D- and 3D-attenuation weighted ordered subsets expectation maximization (AWOSEM), and high-definition reconstruction (HD.PET). We calculated wall/cavity contrast, contrast-to-noise ratio (CNR), wall thickness, motion/thickening and ejection fraction. RESULTS: In the phantom study, we found an increase in defect size (up to 26%), contrast (up to 48%) and CNR (1.9) with HD.PET as compared to standard techniques. The contrast increased on HD.PET images compared to 2D- and 3D-AWOSEM for viability (14.0% +/- 4.8%) and perfusion studies (7.3% +/- 4.3%) (P < .05). Average CNR increased with HD.PET by 79.4% +/- 17.1% and 68.8% +/- 3.0% in viability and perfusion studies respectively (all P < .05). Average wall thickness with HD.PET decreased in the phantom study by 1.3 +/- 0.3 mm and the viability studies by 1.9 +/- 0.7 mm but not in the perfusion studies. The functional measurements were not significantly different for any techniques. CONCLUSIONS: We demonstrated both in phantom and patient cardiac studies that HD.PET improves image contrast, defect definition, and CNR.


Assuntos
Coração/diagnóstico por imagem , Aumento da Imagem , Tomografia por Emissão de Pósitrons , Feminino , Fluordesoxiglucose F18 , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Contração Miocárdica , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Radioisótopos de Rubídio , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...