Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
COPD ; 16(3-4): 227-233, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31357875

RESUMO

Exhaled nitric oxide (FENO) is a marker of type-2 inflammation in asthma and is used in its management. However, smokers and ex-smokers have lower FENO values, and the clinical use of FENO values in COPD patients is unclear. Therefore, we investigated if FENO had a relationship to different COPD characteristics in smoking and ex-smoking subjects. Patients with COPD (n = 533, 58% females) were investigated while in stable condition. Measurements of FENO50, blood cell counts, IgE sensitisation and lung function were performed. Medication reconciliation was used to establish medication usage. Smokers (n = 150) had lower FENO50 9 (8, 10) ppb (geometric mean, 95% confidence interval) than ex-smokers did (n = 383) 15 (14, 16) ppb, p < 0.001. FENO50 was not associated with blood eosinophil or neutrophil levels in smokers, but in ex-smokers significant associations were found (r = 0.23, p < 0.001) and (r = -0.18, p = 0.001), respectively. Lower FENO values were associated with lower FEV1% predicted in both smokers (r = 0.17, p = 0.040) and ex-smokers (r = 0.20, p < 0.001). Neither the smokers nor ex-smokers with reported asthma or IgE sensitisation were linked to an increase in FENO50. Ex-smokers treated with inhaled corticosteroids (ICS) had lower FENO50 14 (13, 15) ppb than non-treated ex-smokers 17 (15, 19) ppb, p = 0.024. This was not found in smokers (p = 0.325). FENO is associated with eosinophil inflammation and the use of ICS in ex-smoking COPD subjects, but not in smoking subjects suggesting that the value of FENO as an inflammatory marker is more limited in smoking subjects. The association found between low FENO values and low lung function requires further investigation.


Assuntos
Óxido Nítrico/metabolismo , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Fumar/efeitos adversos , Corticosteroides/uso terapêutico , Idoso , Testes Respiratórios , Eosinófilos , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Pessoa de Meia-Idade , Espirometria
2.
J Breath Res ; 11(4): 047103, 2017 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-28612760

RESUMO

The lung just like all other organs is affected by age. The lung matures by the age of 20 and age-related changes start around middle age, at 40-50 years. Exhaled nitric oxide (FENO) has been shown to be age, height and gender dependent. We hypothesize that the nitric oxide (NO) parameters alveolar NO (CANO), airway flux (JawNO), airway diffusing capacity (DawNO) and airway wall content (CawNO) will also demonstrate this dependence. Data from healthy subjects were gathered by the current authors from their earlier publications in which healthy individuals were included as control subjects. Healthy subjects (n = 433) ranged in age from 7 to 78 years. Age-stratified reference values of the NO parameters were significantly different. Gender differences were only observed in the 20-49 age group. The results from the multiple regression models in subjects older than 20 years revealed that age, height and gender interaction together explained 6% of variation in FENO at 50 ml s-1 (FENO50), 4% in JawNO, 16% in CawNO, 8% in DawNO and 12% in CANO. In conclusion, in this study we have generated reference values for NO parameters from an extended NO analysis of healthy subjects. This is important in order to be able to use these parameters in clinical practice.


Assuntos
Envelhecimento/fisiologia , Voluntários Saudáveis , Pulmão/metabolismo , Óxido Nítrico/análise , Adolescente , Adulto , Idoso , Testes Respiratórios , Criança , Expiração , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Análise de Regressão , Sistema Respiratório , Adulto Jovem
3.
J Breath Res ; 9(4): 047114, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26670199

RESUMO

Exhaled nitric oxide (F(E)NO) is elevated in asthma, and a clinical practice guideline has been published with recommendations for anti-inflammatory treatment. It summarizes that a F(E)NO at an expiratory flow rate of 50 ml s(-1) (F(E)NO50) above 35 ppb in children indicates eosinophilic inflammation, and the most likely response is to use inhaled corticosteroids. Intermediate F(E)NO50 between 20-35 ppb should be interpreted cautiously. The aim of the study was to investigate this guideline in a small group of asthmatic children. Thirty-seven asthmatic children; 23 boys and 14 girls, visited the outpatient clinic, and provided exhaled breath samples for offline NO measurement. These samples were analysed with chemiluminescence techniques. Three flow rates, namely 16, 90 and 230 ml s(-1) were used for the extended NO analysis (Högman-Meriläinen algorithm, HMA) to estimate the alveolar concentration (C(A)NO), diffusion rate of the airway wall (D(aw)NO) and airway wall content (C(aw)NO). For accuracy of the HMA, the estimated value of F(E)NO at 50 ml s(-1) (F(E)NO50) was compared with measured F(E)NO50. In nine children the difference was more than 5 ppb and the data were therefore excluded. Five children with F(E)NO50 <20 ppb had no known allergy and their F(E)NO50 geometrical mean (25th; 75th percentile) was 11 (10;14) and CawNO was 32 (20;43) ppb. Ten children with F(E)NO50 > 35 ppb had an allergy and had F(E)NO50 of 56 (47;60) ppb and C(aw)NO of 140 (121;172) ppb. Thirteen children with allergies, with intermediate F(E)NO50, had F(E)NO50 of 27 (25;30) ppb with a wide range of C(aw)NO. In five of these children, values were comparable to healthy children, 44 (43;50) ppb while eight children had elevated C(aw)NO values of 108 (95;129) ppb. Our data indicate the clinical potential use of extended NO analysis to determine the personal target value of F(E)NO50 for monitoring the treatment outcome. Furthermore, for children with intermediate F(E)NO50 more than half of them could possibly benefit from an adjustment of inhaled corticosteroids if the C(aw)NO value was considered.


Assuntos
Anti-Inflamatórios/uso terapêutico , Asma/tratamento farmacológico , Testes Respiratórios/métodos , Óxido Nítrico/análise , Medicina de Precisão , Administração por Inalação , Corticosteroides/administração & dosagem , Corticosteroides/uso terapêutico , Anti-Inflamatórios/administração & dosagem , Criança , Expiração , Feminino , Humanos , Masculino , Pressão
4.
J Breath Res ; 8(1): 016002, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24565997

RESUMO

Expired nitric oxide (NO) is used as a biomarker in different respiratory diseases. The recommended flow rate of 50 mL s⁻¹ (F(E)NO0.05) does not reveal from where in the lung NO production originated. Theoretical models of NO transfer from the respiratory system, linear or nonlinear approaches, have therefore been developed and applied. These models can estimate NO from distal lung (alveolar NO) and airways (bronchial flux). The aim of this study was to show the limitation in exhaled flow rate for the theoretical models of NO production in the respiratory system, linear and nonlinear models. Subjects (n = 32) exhaled at eight different flow rates between 10-350 mL s⁻¹ for the theoretical protocols. Additional subjects (n = 32) exhaled at tree flow rates (20, 100 and 350 mL s⁻¹) for the clinical protocol. When alveolar NO is calculated using high flow rates with the linear model, correction for axial back diffusion becomes negligible, -0.04 ppb and bronchial flux enhanced by 1.27. With Högman and Meriläinen algorithm (nonlinear model) the corrections factors can be understood to be embedded, and the flow rates to be used are ≤20, 100 and ≥350 mL s⁻¹. Applying these flow rates in a clinical setting any F(E)NO can be calculated necessitating fewer exhalations. Hence, measured F(E)NO0.05 12.9 (7.2-18.7) ppb and calculated 12.9 (6.8-18.7) ppb. In conclusion, the only possibility to avoid inconsistencies between research groups is to use the measured NO values as such in modelling, and apply tight quality control to accuracies in both NO concentration and exhaled flow measurements.


Assuntos
Testes Respiratórios/métodos , Modelos Teóricos , Óxido Nítrico/análise , Sistema Respiratório/metabolismo , Adulto , Idoso , Simulação por Computador , Difusão , Expiração , Voluntários Saudáveis , Humanos , Pessoa de Meia-Idade , Dinâmica não Linear , Análise de Regressão , Testes de Função Respiratória , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...