Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Anaesthesiol Scand ; 68(4): 502-511, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38286568

RESUMO

BACKGROUND: Several studies report lack of meropenem pharmacokinetic/pharmacodynamic (PK/PD) target attainment (TA) and risk of therapeutic failure with intermittent bolus infusions in intensive care unit (ICU) patients. The aim of this study was to describe meropenem TA in an ICU population and the clinical response in the first 72 h after therapy initiation. METHODS: A prospective observational study of ICU patients ≥18 years was conducted from 2014 to 2017. Patients with normal renal clearance (NRC) and augmented renal clearance (ARC) and patients on continuous renal replacement therapy (CRRT) were included. Meropenem was administered as intermittent bolus infusions, mainly at a dose of 1 g q6h. Peak, mid, and trough levels were sampled at 24, 48, and 72 h after therapy initiation. TA was defined as 100% T > 4× MIC or trough concentration above 4× MIC. Meropenem PK was estimated using traditional calculation methods and population pharmacokinetic modeling (P-metrics®). Clinical response was evaluated by change in C-reactive protein (CRP), Sequential Organ Failure Assessment (SOFA) score, leukocyte count, and defervescence. RESULTS: Eighty-seven patients were included, with a median Simplified Acute Physiology (SAPS) II score 37 and 90 days mortality rate of 32%. Median TA was 100% for all groups except for the ARC group with 45.5%. Median CRP fell from 175 (interquartile range [IQR], 88-257) to 70 (IQR, 30-114) (p < .001) in the total population. A reduction in SOFA score was observed only in the non-CRRT groups (p < .001). CONCLUSION: Intermittent meropenem bolus infusion q6h gives satisfactory TA in an ICU population with variable renal function and CRRT modality, except for ARC patients. No consistent relationship between TA and clinical endpoints were observed.


Assuntos
Antibacterianos , Estado Terminal , Humanos , Meropeném/farmacocinética , Antibacterianos/uso terapêutico , Estado Terminal/terapia , Cuidados Críticos , Unidades de Terapia Intensiva
2.
Lab Anim ; 58(1): 34-43, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37669442

RESUMO

Serum corticosterone, serum buprenorphine, body weight change, consumption of food and water and behaviour-based pain assessment were measured in catheterised and non-catheterised male Wistar rats undergoing myocardial infarct (MI) surgery under general anaesthesia following buprenorphine dosing by subcutaneous (Bup-SC, 0.05 mg/kg) and oral (Bup-O, 0.4 mg/kg) routes. Buprenorphine was dosed subcutaneously at half an hour before and 8, 16 and 24 hours after surgery (Bup-SC), orally at one hour before surgery (Bup-O1) or at one hour before and 12 hours after surgery (Bup-O2) in catheterised rats and at one hour before and 24 hours after surgery (Bup-O24) in non-catheterised rats. Serum corticosterone, body weight changes and food and water consumption were not significantly different between treatments in catheterised rats. Bup-SC resulted in rapidly decreasing serum concentrations below the clinically effective concentrations (1 ng/mL) already at two hours after the first dose. Bup-O provided significantly higher and slowly decreasing serum concentrations, at or above clinically effective concentrations, for 24 hours (Bup-O1) and 42 hours (Bup-O2) after surgery. In non-catheterised rats, body weight development and food consumption were significantly higher in Bup-O24 rats compared to Bup-SC rats. The results indicate that a SC buprenorphine dose of 0.05 mg/kg every eight hours provides long periods of serum concentrations below clinically effective levels, and that a higher dose and/or more frequent dosage are required to provide stable serum concentrations at or above clinically effective levels. A single oral buprenorphine dose of 0.4 mg/kg provides clinically effective and stable serum concentrations for 24 hours in rats after MI surgery.


Assuntos
Buprenorfina , Ratos , Masculino , Animais , Analgésicos Opioides , Corticosterona , Ratos Wistar , Resultado do Tratamento , Peso Corporal
3.
J Pharm Biomed Anal ; 219: 114908, 2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-35803015

RESUMO

We developed three ultra-high pressure liquid chromatography coupled to mass spectrometry detection (UHPLC-MS/MS) methods to quantify 25 antihypertensive drugs in serum samples. Patient-reported drug lists were collected, and drug concentrations were analysed in samples from 547 patients, half with uncontrolled hypertension, and all treated with ≥ 2 antihypertensive drugs. For sample preparation, serum was mixed with deuterated internal standards and acetonitrile and precipitated. Aliquots of the supernatant were injected on UHPLC-MSMS with a C18 reversed phase column. The mobile phase was 0.1 % HCOOH (formic acid) in water and 0.1 % HCOOH in acetonitrile (except in methanol for spironolactone/canrenone) at a flow rate of 0.4 mL/min. The calibrators and internal controls were prepared in Autonorm™. The calibration ranges were wide, and the models were linear or quadratic with squared correlation coefficients ≥ 0.97. The limits of detection and quantification, specificity, carry-over, and matrix effects were acceptable. The accuracy of the internal controls was in the range 85-121 %, and the intermediate precision for all drugs was 4-28 %. The patient-reported antihypertensive drug use and the detected serum drug concentrations were in accordance with that most frequently prescribed nationally. The percent non-detectable level was 5-10 % for bendroflumethiazide, doxazosin, nifedipine, and ramipril. Often the drug dose chosen was lower than the recommended maximum daily dose. We report the maximum (Cmax) and minimum (Cmin) drug concentrations after drug intake. The inter-individual pharmacokinetic variability at Cmin was 18-fold for hydrochlorothiazide, 22-fold for losartan carboxyl acid, 26-fold for amlodipine, 44-fold for candesartan, and 50-fold for valsartan. Our methods are suitable for measuring antihypertensive drugs in patient serum for therapy control.


Assuntos
Anti-Hipertensivos , Hipertensão , Acetonitrilas , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Hipertensão/tratamento farmacológico , Espectrometria de Massas em Tandem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...