Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Tech (Berl) ; 68(5): 503-510, 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37099745

RESUMO

OBJECTIVES: Left ventricular assist devices (LVADs) have been established as alternative to heart transplantation for patients with end-stage heart failure refractory to medical therapy. Right heart failure (RHF) after LVAD implantation is associated with inferior outcome. Its preoperative anticipation may influence the selection between a pure left ventricular and a biventricular device type and, thus, improve outcomes. Reliable algorithms to predict RHF are missing. METHODS: A numerical model was used for simulation of a cardiovascular circulation. The LVAD was placed as parallel circuit between left ventricle and aorta. In contrast to other studies, the dynamic hydraulic behavior of a pulsatile LVAD was replaced by that of a continuous LVAD. A variety of hemodynamic states was tested mimicking different right heart conditions. Adjustable parameters included heart rate (HR), pulmonary vascular resistance (PVR), tricuspid regurgitation (TR), right ventricular contractility (RVC) and pump speed. Outcome parameters comprised central venous pressure (CVP), mean pulmonary artery pressure (mPAP), cardiac output (CO) and occurrence of suction. RESULTS: Alteration of HR, PVR, TR, RVC and pump speed resulted in diverse effects on CO, CVP and mPAP, resulting in improvement, impairment or no change of the circulation, depending on the degree of alteration. CONCLUSIONS: The numerical simulation model allows prediction of circulatory changes and LVAD behaviour following variation of hemodynamic parameters. Such a prediction may be of particular advantage to anticipate RHF after LVAD implantation. It may help preoperatively to choose the appropriate strategy of only left ventricular or both left and right ventricular support.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Disfunção Ventricular Direita , Humanos , Ventrículos do Coração , Hemodinâmica , Insuficiência Cardíaca/terapia , Estudos Retrospectivos , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/terapia
2.
Diagnostics (Basel) ; 13(2)2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36672990

RESUMO

In many cardiac diseases, right and left ventricular volumes in systole and diastole are diagnostically and prognostically relevant. Measurements are made by segmentation of the myocardial borders on cardiac magnetic resonance (CMR) images. Automatic detection of myocardial contours is possible by signal thresholding techniques, but must be validated before use in clinical settings. Biventricular volumes were measured in end-diastole (EDVi) and in end-systole (ESVi) both manually and with the MassK application, with signal thresholds at 30%, 50%, and 70%. Stroke volumes (SV) and cardiac indices (CI) were calculated from volumetric measurements and from flow measured in the ascending aorta and the main pulmonary artery, and both methods were compared. Reproducibility of volumetric measurements was tested in 20 patients. Measurements were acquired in 94 patients aged 15 ± 9 years referred for various conditions. EDVi and ESVi of both ventricles were largest with manual segmentation and inversely proportional to the MassK threshold. Manual and k30 SV and CI corresponded best to flow measurements. Interobserver variability was low for all volumes manually and with MassK. In conclusion, manual and 30% threshold-based biventricular volume segmentation agree best with two-dimensional, phantom-corrected phase contrast flow measurements in a young cardiac referral population and are well reproducible.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...