Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Clin Nutr ; 118(4): 812-821, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37598747

RESUMO

BACKGROUND: New recommendations for the assessment of malnutrition and sarcopenia include body composition, specifically reduced muscle mass. Three-dimensional optical imaging (3DO) is a validated, accessible, and affordable alternative to dual X-ray absorptiometry (DXA). OBJECTIVE: Identify strengths and weaknesses of 3DO for identification of malnutrition in participants with low body mass index (BMI) and eating disorders. DESIGN: Participants were enrolled in the cross-sectional Shape Up! Adults and Kids studies of body shape, metabolic risk, and functional assessment and had BMI of <20 kg/m2 in adults or <85% of median BMI (mBMI) in children and adolescents. A subset was referred for eating disorders evaluation. Anthropometrics, scans, strength testing, and questionnaires were completed in clinical research centers. Lin's Concordance Correlation Coefficient (CCC) assessed agreement between 3DO and DXA; multivariate linear regression analysis examined associations between weight history and body composition. RESULTS: Among 95 participants, mean ± SD BMI was 18.3 ± 1.4 kg/m2 in adult women (N = 56), 19.0 ± 0.6 in men (N = 14), and 84.2% ± 4.1% mBMI in children (N = 25). Concordance was excellent for fat-free mass (FFM, CCC = 0.97) and strong for appendicular lean mass (ALM, CCC = 0.86) and fat mass (FM, CCC = 0.87). By DXA, 80% of adults met the low FFM index criterion for malnutrition, and 44% met low ALM for sarcopenia; 52% of children and adolescents were <-2 z-score for FM. 3DO identified 95% of these cases. In the subset, greater weight loss predicted lower FFM, FM, and ALM by both methods; a greater percentage of weight regained predicted a higher percentage of body fat. CONCLUSIONS: 3DO can accurately estimate body composition in participants with low BMI and identify criteria for malnutrition and sarcopenia. In a subset, 3DO detected changes in body composition expected with weight loss and regain secondary to eating disorders. These findings support the utility of 3DO for body composition assessment in patients with low BMI, including those with eating disorders. This trial was registered at clinicaltrials.gov as NCT03637855.


Assuntos
Transtornos da Alimentação e da Ingestão de Alimentos , Desnutrição , Sarcopenia , Adulto , Masculino , Criança , Adolescente , Humanos , Feminino , Índice de Massa Corporal , Composição Corporal/fisiologia , Desnutrição/diagnóstico , Absorciometria de Fóton/métodos , Redução de Peso
2.
Clin Nutr ; 42(9): 1619-1630, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37481870

RESUMO

BACKGROUND: Excess adiposity in children is strongly correlated with obesity-related metabolic disease in adulthood, including diabetes, cardiovascular disease, and 13 types of cancer. Despite the many long-term health risks of childhood obesity, body mass index (BMI) Z-score is typically the only adiposity marker used in pediatric studies and clinical applications. The effects of regional adiposity are not captured in a single scalar measurement, and their effects on short- and long-term metabolic health are largely unknown. However, clinicians and researchers rarely deploy gold-standard methods for measuring compartmental fat such as magnetic resonance imaging (MRI) and dual X-ray absorptiometry (DXA) on children and adolescents due to cost or radiation concerns. Three-dimensional optical (3DO) scans are relatively inexpensive to obtain and use non-invasive and radiation-free imaging techniques to capture the external surface geometry of a patient's body. This 3D shape contains cues about the body composition that can be learned from a structured correlation between 3D body shape parameters and reference DXA scans obtained on a sample population. STUDY AIM: This study seeks to introduce a radiation-free, automated 3D optical imaging solution for monitoring body shape and composition in children aged 5-17. METHODS: We introduce an automated, linear learning method to predict total and regional body composition of children aged 5-17 from 3DO scans. We collected 145 male and 206 female 3DO scans on children between the ages of 5 and 17 with three scanners from independent manufacturers. We used an automated shape templating method first introduced on an adult population to fit a topologically consistent 60,000 vertex (60 k) mesh to 3DO scans of arbitrary scanning source and mesh topology. We constructed a parameterized body shape space using principal component analysis (PCA) and estimated a regression matrix between the shape parameters and their associated DXA measurements. We automatically fit scans of 30 male and 38 female participants from a held-out test set and predicted 12 body composition measurements. RESULTS: The coefficient of determination (R2) between 3DO predicted body composition and DXA measurements was at least 0.85 for all measurements with the exception of visceral fat on 3D scan predictions. Precision error was 1-4 times larger than that of DXA. No predicted variable was significantly different from DXA measurement except for male trunk lean mass. CONCLUSION: Optical imaging can quickly, safely, and inexpensively estimate regional body composition in children aged 5-17. Frequent repeat measurements can be taken to chart changes in body adiposity over time without risk of radiation overexposure.


Assuntos
Obesidade Infantil , Adulto , Adolescente , Humanos , Criança , Masculino , Feminino , Pré-Escolar , Obesidade Infantil/diagnóstico por imagem , Composição Corporal , Índice de Massa Corporal , Absorciometria de Fóton/métodos , Adiposidade
3.
Am J Clin Nutr ; 118(3): 657-671, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37474106

RESUMO

BACKGROUND: The obesity epidemic brought a need for accessible methods to monitor body composition, as excess adiposity has been associated with cardiovascular disease, metabolic disorders, and some cancers. Recent 3-dimensional optical (3DO) imaging advancements have provided opportunities for assessing body composition. However, the accuracy and precision of an overall 3DO body composition model in specific subgroups are unknown. OBJECTIVES: This study aimed to evaluate 3DO's accuracy and precision by subgroups of age, body mass index, and ethnicity. METHODS: A cross-sectional analysis was performed using data from the Shape Up! Adults study. Each participant received duplicate 3DO and dual-energy X-ray absorptiometry (DXA) scans. 3DO meshes were digitally registered and reposed using Meshcapade. Principal component analysis was performed on 3DO meshes. The resulting principal components estimated DXA whole-body and regional body composition using stepwise forward linear regression with 5-fold cross-validation. Duplicate 3DO and DXA scans were used for test-retest precision. Student's t tests were performed between 3DO and DXA by subgroup to determine significant differences. RESULTS: Six hundred thirty-four participants (females = 346) had completed the study at the time of the analysis. 3DO total fat mass in the entire sample achieved R2 of 0.94 with root mean squared error (RMSE) of 2.91 kg compared to DXA in females and similarly in males. 3DO total fat mass achieved a % coefficient of variation (RMSE) of 1.76% (0.44 kg), whereas DXA was 0.98% (0.24 kg) in females and similarly in males. There were no mean differences for total fat, fat-free, percent fat, or visceral adipose tissue by age group (P > 0.068). However, there were mean differences for underweight, Asian, and Black females as well as Native Hawaiian or other Pacific Islanders (P < 0.038). CONCLUSIONS: A single 3DO body composition model produced accurate and precise body composition estimates that can be used on diverse populations. However, adjustments to specific subgroups may be warranted to improve the accuracy in those that had significant differences. This trial was registered at clinicaltrials.gov as NCT03637855 (Shape Up! Adults).


Assuntos
Composição Corporal , Etnicidade , Adulto , Feminino , Humanos , Masculino , Absorciometria de Fóton/métodos , Índice de Massa Corporal , Estudos Transversais , Obesidade/diagnóstico por imagem , Imagem Óptica
4.
Am J Clin Nutr ; 117(4): 802-813, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36796647

RESUMO

BACKGROUND: Recent 3-dimensional optical (3DO) imaging advancements have provided more accessible, affordable, and self-operating opportunities for assessing body composition. 3DO is accurate and precise in clinical measures made by DXA. However, the sensitivity for monitoring body composition change over time with 3DO body shape imaging is unknown. OBJECTIVES: This study aimed to evaluate the ability of 3DO in monitoring body composition changes across multiple intervention studies. METHODS: A retrospective analysis was performed using intervention studies on healthy adults that were complimentary to the cross-sectional study, Shape Up! Adults. Each participant received a DXA (Hologic Discovery/A system) and 3DO (Fit3D ProScanner) scan at the baseline and follow-up. 3DO meshes were digitally registered and reposed using Meshcapade to standardize the vertices and pose. Using an established statistical shape model, each 3DO mesh was transformed into principal components, which were used to predict whole-body and regional body composition values using published equations. Body composition changes (follow-up minus the baseline) were compared with those of DXA using a linear regression analysis. RESULTS: The analysis included 133 participants (45 females) in 6 studies. The mean (SD) length of follow-up was 13 (5) wk (range: 3-23 wk). Agreement between 3DO and DXA (R2) for changes in total FM, total FFM, and appendicular lean mass were 0.86, 0.73, and 0.70, with root mean squared errors (RMSEs) of 1.98 kg, 1.58 kg, and 0.37 kg, in females and 0.75, 0.75, and 0.52 with RMSEs of 2.31 kg, 1.77 kg, and 0.52 kg, in males, respectively. Further adjustment with demographic descriptors improved the 3DO change agreement to changes observed with DXA. CONCLUSIONS: Compared with DXA, 3DO was highly sensitive in detecting body shape changes over time. The 3DO method was sensitive enough to detect even small changes in body composition during intervention studies. The safety and accessibility of 3DO allows users to self-monitor on a frequent basis throughout interventions. This trial was registered at clinicaltrials.gov as NCT03637855 (Shape Up! Adults; https://clinicaltrials.gov/ct2/show/NCT03637855); NCT03394664 (Macronutrients and Body Fat Accumulation: A Mechanistic Feeding Study; https://clinicaltrials.gov/ct2/show/NCT03394664); NCT03771417 (Resistance Exercise and Low-Intensity Physical Activity Breaks in Sedentary Time to Improve Muscle and Cardiometabolic Health; https://clinicaltrials.gov/ct2/show/NCT03771417); NCT03393195 (Time Restricted Eating on Weight Loss; https://clinicaltrials.gov/ct2/show/NCT03393195), and NCT04120363 (Trial of Testosterone Undecanoate for Optimizing Performance During Military Operations; https://clinicaltrials.gov/ct2/show/NCT04120363).


Assuntos
Composição Corporal , Imagem Óptica , Masculino , Adulto , Feminino , Humanos , Absorciometria de Fóton/métodos , Estudos Transversais , Estudos Retrospectivos , Composição Corporal/fisiologia , Impedância Elétrica , Índice de Massa Corporal
5.
Med Phys ; 49(10): 6395-6409, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35837761

RESUMO

BACKGROUND: Many predictors of morbidity caused by metabolic disease are associated with body shape. 3D optical (3DO) scanning captures body shape and has been shown to accurately and precisely predict body composition variables associated with mortality risk. 3DO is safer, less expensive, and more accessible than criterion body composition assessment methods such as dual-energy X-ray absorptiometry (DXA). However, 3DO scanning has not been standardized across manufacturers for pose, mesh resolution, and post processing methods. PURPOSE: We introduce a scanner-agnostic algorithm that automatically fits a topologically consistent human mesh to 3DO scanned point clouds and predicts clinically important body metrics using a standardized body shape model. Our models transform raw scans captured by any 3DO scanner into fixed topology meshes with anatomical consistency, standardizing the outputs of 3DO scans across manufacturers and allowing for the use of common prediction models across scanning devices. METHODS: A fixed-topology body mesh template was automatically registered to 848 training scans from three different 3DO systems. Participants were between 18 and 89 years old with body mass index ranging from 14 to 52 kg/m2 . Scans were registered by first performing a coarse nearest neighbor alignment between the template and the input scan with an anatomically constrained principal component analysis (PCA) domain deformation using a device and gender specific bootstrap basis trained on 70 seed scans each. The template mesh was then optimized to fit the target with a smooth per-vertex surface-to-surface deformation. A combined unified PCA model was created from the superset of all automatically fit training scans including all three devices. Body composition predictions to DXA measurements were learned from the training mesh PCA coefficients using linear regression. Using this final unified model, we tested the accuracy of our body composition models on a withheld sample of 562 scans by fitting a PCA parameterized template mesh to each raw scan and predicting the expected body composition metrics from the principal components using the learned regression model. RESULTS: We achieved coefficients of determination (R2 ) above 0.8 on all nine fat and lean predictions except female visceral fat (0.77). R2 was as high as 0.94 (total fat and lean, trunk fat), and all root-mean-squared errors were below 3.0 kg. All predicted body composition variables were not significantly different from reference DXA measurements except for visceral fat and female trunk fat. Repeatability precision as measured by the coefficient of variation (%CV) was around 2-3x worse than DXA precision, with visceral fat %CV below 2x DXA %CV and female total fat mass at 5x. CONCLUSIONS: Our method provides an accurate, automated, and scanner agnostic framework for standardizing 3DO scans and a low cost, radiation-free alternative to criterion radiology imaging for body composition analysis. We published a web-app version of this work at https://shapeup.shepherdresearchlab.org/3do-bodycomp-analyzer/ that accepts mesh file uploads and returns templated meshes with body composition predictions for demo purposes.


Assuntos
Tecido Adiposo , Composição Corporal , Absorciometria de Fóton , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Modelos Lineares , Pessoa de Meia-Idade , Análise de Componente Principal , Cintilografia , Adulto Jovem
6.
Med Phys ; 47(12): 6232-6245, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32978970

RESUMO

PURPOSE: Total and regional body composition are important indicators of health and mortality risk, but their measurement is usually restricted to controlled environments in clinical settings with expensive and specialized equipment. A method that approaches the accuracy of the current gold standard method, dual-energy x-ray absorptiometry (DXA), while only requiring input from widely available consumer grade equipment, would enable the measurement of these important biometrics in the wild, enabling data collection at a scale that would have previously been prohibitive in time and expense. We describe an algorithm for predicting three-dimensional (3D) body shape and composition from a single frontal 2-dimensional image acquired with a digital consumer camera. METHODS: Duplicate 3D optical scans, two-dimensional (2D) optical images, and DXA whole-body scans were available for 183 men and 233 women from the Shape Up! Adults Study. A principal component analysis vector basis was fit to 3D point clouds of a training subset of 152 men and 194 women. The relationship between this vector space and DXA-derived body composition was modeled with linear regression. The principal component 3D shape was then fitted to match a silhouette extracted from a 2D photograph of a novel body. Body composition was predicted from the resulting 3D shape match using the linear mapping between the principal component parameters and the DXA metrics. Accuracy of body composition estimates from the silhouette method was evaluated against a simple model using height and weight as a baseline, and against DXA measurements as ground truth. Test-retest precision of the silhouette method was evaluated using the duplicate 2D optical images and compared against precision of the duplicate DXA scans. Paired t-tests were performed to detect significant differences between the sets. RESULTS: Results were reported on a held-out set. Body composition prediction achieved R2 s of 0.81 and 0.74 for percent fat prediction of males and females, respectively, on a held-out test set consisting of 31 males and 39 females. Precision estimates for fat mass were 2.31% and 2.06% for males and females, respectively, compared to 1.26% and 0.68% for DXA scans. The t-tests revealed no statistically significant differences between the silhouette method measurements and DXA measurements, or between retests. CONCLUSION: Total and regional body composition measures can be estimated from a single frontal photograph of a human body. Body composition prediction using consumer level photography can enable early screening and monitoring of possible physiological indicators of metabolic disease in regions where medical imagery or clinical assessment is inaccessible.


Assuntos
Composição Corporal , Somatotipos , Absorciometria de Fóton , Tecido Adiposo , Adulto , Peso Corporal , Feminino , Humanos , Masculino , Fotografação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...