Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 96(14): 5428-5436, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38551643

RESUMO

Rheumatoid arthritis (RA), a common chronic inflammatory illness, is still incurable, reducing the sufferers' quality of life significantly. Adenosine 5'-triphosphate (ATP) and hypochlorous acid (HOCl) are key indicators in RA, but their precise mechanisms in RA pathophysiology are unknown. As a result, in order to detect ATP and HOCl simultaneously, we created two new dual-channel/localization single-molecule fluorescence probes, RhTNMB and RhFNMB. Furthermore, RhFNMB outperformed RhTNMB in terms of detection performance. ATP and HOCl produce independent fluorescence responses in the light red channel (λex = 520 nm, λem = 586 nm) and deep red channel (λex = 620 nm, λem = 688 nm), respectively, without spectral crosstalk. It should be noted that the probe RhFNMB successfully imaged ATP in mitochondria and HOCl in cells. Surprisingly, the probe RhFNMB demonstrated remarkable detection ability in the diagnosis and treatment of Pseudomonas aeruginosa-induced abdominal inflammation in mice. We continued to apply the probe RhFNMB to track ATP and HOCl in RA and discovered that ATP and HOCl concentrations were considerably greater in RA joints than in normal joints. We also confirmed the therapeutic effect of methotrexate on RA. This study is the first to achieve dual-channel imaging of ATP and HOCl, which is of great value for the early diagnosis and therapy of RA.


Assuntos
Artrite Reumatoide , Ácido Hipocloroso , Animais , Camundongos , Fluorescência , Corantes Fluorescentes , Qualidade de Vida , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/tratamento farmacológico , Diagnóstico Precoce
2.
Anal Chem ; 95(11): 5034-5044, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36898151

RESUMO

Adenosine triphosphate (ATP), as an important intracellular energy currency produced in mitochondria, is closely related to various diseases in living organisms. Currently, the biological application of AIE fluorophore as a fluorescent probe for ATP detection in mitochondria is rarely reported. Herein, D-π-A and D-A structure-based tetraphenylethylene (TPE) fluorophores were employed to synthesize six different ATP probes (P1-P6), and the phenylboronic acid groups and dual positive charge sites of probes could interact with the vicinal diol of ribose and negatively charged triphosphate structure of ATP, respectively. However, P1 and P4 with a boronic acid group and a positive charge site had poor selectivity for ATP detection. In contrast, P2, P3, P5, and P6 with dual positive charge sites exhibited better selectivity than P1 and P4. In particular, P2 had more advantages of high sensitivity, selectivity, and good time stability for ATP detection than P3, P5, and P6, which was ascribed to its D-π-A structure, linker 1 (1,4-bis(bromomethyl)benzene), and dual positive charge recognition sites. Then, P2 was employed to detect ATP, and it exhibited a low detection limit of 3.62 µM. Moreover, P2 showed utility in the monitoring of mitochondrial ATP level fluctuations.


Assuntos
Corantes Fluorescentes , Estilbenos , Corantes Fluorescentes/química , Trifosfato de Adenosina , Mitocôndrias
3.
Analyst ; 148(1): 38-46, 2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36416251

RESUMO

Mitochondria are important subcellular organelles involved in many cellular activities. Therefore, it is very important to monitor the concentration of various substances in mitochondria. In this work, we constructed a dual-response mitochondria-targeted fluorescent probe HBTN for the detection of viscosity and HOCl in vitro and in vivo. HBTN not only has a long emission wavelength with an emission peak of 680 nm, but also has a large Stokes shift of 278 nm. The fluorescence intensity of probe HBTN at 680 nm has a good linear relationship with solution viscosity, which can be used for quantitative detection of viscosity. In addition, the probe HBTN enables ratiometric detection of HOCl with a low detection limit (DL = 24.5 nM) and rapid response (<20 min). More importantly, the probe HBTN has been successfully applied to the detection of viscosity and exogenous/endogenous HOCl in the mitochondria of MCF-7 cells. Furthermore, the probe HBTN has been implemented in imaging viscosity and HOCl in zebrafish. HBTN is expected to be a practical tool for monitoring viscosity and HOCl in vivo.


Assuntos
Corantes Fluorescentes , Peixe-Zebra , Humanos , Animais , Viscosidade , Mitocôndrias , Microscopia de Fluorescência/métodos , Ácido Hipocloroso
4.
Spectrochim Acta A Mol Biomol Spectrosc ; 281: 121649, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-35872428

RESUMO

Hypochlorous acid is an important active substance involved in a variety of physiological processes in living organisms, while abnormal concentrations of HOCl are strongly associated with a variety of diseases such as cancer, inflammation, atherosclerosis, and Alzheimer's disease. As a result, it's crucial to establish a reliable method for tracking HOCl in vivo in order to investigate its physiological consequences. In this work, we developed a fluorescent probe DFSN with both AIE and ESIPT for imaging HOCl in vivo. DFSN not only has a basic structure and is easy to synthesize, but also has superior performance. The probe responds to HOCl in less than 10 s and has good selectivity and sensitivity to HOCl (DL = 6.3 nM), with a 110-fold increase in fluorescence intensity following response. In addition, DFSN can realize the rapid detection of hypochlorous acid with naked eyes. Moreover, DFSN can be used for the detection of exogenous and endogenous HOCl in RAW264.7 cells, and additionally enables the tracking of HOCl in cancer cells (Hela cells and HepG2 cells). More notably, it has been utilized to image hypochlorous acid in zebrafish with great success. The probe DFSN will be useful in determining the physiological significance of HOCl.


Assuntos
Corantes Fluorescentes , Ácido Hipocloroso , Animais , Corantes Fluorescentes/química , Células HeLa , Humanos , Ácido Hipocloroso/química , Camundongos , Células RAW 264.7 , Peixe-Zebra
5.
Anal Chem ; 94(12): 5006-5013, 2022 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-35294170

RESUMO

Small-molecule biothiols, including cysteine (Cys), homocysteine (Hcy), and glutathione (GSH), participate in various pathological and physiological processes. It is still a challenge to simultaneously distinguish Cys and Hcy because of their similar structures and reactivities, as well as the interference from the high intramolecular concentration of GSH. Herein, a novel fluorescent probe, CySI, based on cyanine and thioester was developed to differentiate Cys and Hcy through a single-wavelength excitation and two distinctly separated emission channels. The probe exhibited a turn-on fluorescence response to Cys at both 625 nm (the red channel) and 740 nm (the near-infrared channel) but only showed fluorescence turn-on to Hcy at 740 nm (the near-infrared channel) and no fluorescent response to GSH. With the aid of built-in self-calibration of single excitation and dual emissions, simultaneous discriminative determinations of Cys and Hcy were realized through red and near-infrared channels. CySI exhibited excellent selectivity toward Cys and Hcy with a fast response. This probe was further exploited to visualize exogenous Cys and Hcy in cells through dual emission channels under one excitation. Moreover, it could efficiently target mitochondria and was applied to monitor the endogenous Cys fluctuations independently in mitochondria through the red emission channel.


Assuntos
Cisteína , Corantes Fluorescentes , Corantes Fluorescentes/química , Glutationa , Células HeLa , Homocisteína , Humanos , Espectrometria de Fluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...