Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 126
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Bioelectrochemistry ; 160: 108784, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39094447

RESUMO

Infectious diseases have threatened human life for as long as humankind has existed. One of the most crucial aspects of fighting against these infections is diagnosis to prevent disease spread. However, traditional diagnostic methods prove insufficient and time-consuming in the face of a pandemic. Therefore, studies focusing on detecting viruses causing these diseases have increased, with a particular emphasis on developing rapid, accurate, specific, user-friendly, and portable electrochemical biosensor systems. Peptides are used integral components in biosensor fabrication for several reasons, including various and adaptable synthesis protocols, long-term stability, and specificity. Here, we discuss peptide-based electrochemical biosensor systems that have been developed over the last decade for the detection of infectious diseases. In contrast to other reports on peptide-based biosensors, we have emphasized the following points i) the synthesis methods of peptides for biosensor applications, ii) biosensor fabrication approaches of peptide-based electrochemical biosensor systems, iii) the comparison of electrochemical biosensors with other peptide-based biosensor systems and the advantages and limitations of electrochemical biosensors, iv) the pros and cons of peptides compared to other biorecognition molecules in the detection of infectious diseases, v) different perspectives for future studies with the shortcomings of the systems developed in the past decade.


Assuntos
Técnicas Biossensoriais , Doenças Transmissíveis , Técnicas Eletroquímicas , Peptídeos , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Humanos , Peptídeos/química , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Doenças Transmissíveis/diagnóstico , Doenças Transmissíveis/virologia
2.
Talanta ; 280: 126688, 2024 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-39128315

RESUMO

In contemporary society, developing dependable point-of-care (POC) biosensors for the timely detection of cancer markers is crucial. Among various sensor types, screen-printed electrode (SPE)-based sensors, particularly electrochemical ones, stand out as promising candidates for POC applications. Despite ongoing efforts to create numerous SPE-based sensors, there is a continuous pursuit to enhance their sensitivity and analytical capabilities. This study presents an advanced electrochemical sensor designed to sensitively detect the hepatocellular carcinoma (HCC) marker Alpha-fetoprotein (AFP) in saliva. The sensor employs a gold SPE modified with hydroxyapatite, TiO2 nanoparticles, 1-butyl-3-methylimidazolium bis(trifluoromethyl sulfonyl)imide ionic liquid (IL), and AFP monoclonal antibodies. After thorough characterization and optimization using cyclic voltammetry (CV) and differential pulse voltammetry (DPV), the biosensor exhibited a broad detection range (0.01-400 ng/mL), a low limit of detection (LOD) at 0.058 ng/mL, and demonstrated high selectivity, repeatability, reproducibility, and stability. Furthermore, when tested with spiked human saliva samples, the biosensor displayed excellent recovery and robustness, showcasing its potential for noninvasive and POC diagnosis of HCC. In an environmentally conscious evaluation, the biosensor's greenness was assessed using the AGREE metric, yielding a high score of 0.85. This score indicates the biosensor's alignment with the principles of green analytical chemistry, underlining its eco-friendly attributes. This innovative electrochemical sensor contributes to the ongoing efforts for efficient and reliable POC diagnostic tools and aligns with a broader commitment to developing environmentally friendly solutions.


Assuntos
Técnicas Biossensoriais , Durapatita , Técnicas Eletroquímicas , Líquidos Iônicos , Saliva , Titânio , alfa-Fetoproteínas , Líquidos Iônicos/química , Titânio/química , Durapatita/química , Humanos , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos , alfa-Fetoproteínas/análise , alfa-Fetoproteínas/imunologia , Saliva/química , Limite de Detecção , Eletrodos , Química Verde , Biomarcadores Tumorais/análise
3.
Cancer Med ; 13(15): e70079, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39118454

RESUMO

BACKGROUND: Cancer remains a formidable global health challenge, currently affecting nearly 20 million individuals worldwide. Due to the absence of universally effective treatments, ongoing research explores diverse strategies to combat this disease. Recent efforts have concentrated on developing combined drug regimens and targeted therapeutic approaches. OBJECTIVE: This study aimed to investigate the anticancer efficacy of a conjugated drug system, consisting of doxorubicin and cisplatin (Dox-Cis), encapsulated within niosomes and modified with MUC-1 aptamers to enhance biocompatibility and target specific cancer cells. METHODS: The chemical structure of the Dox-Cis conjugate was characterized using Fourier Transform Infrared Spectroscopy (FTIR) and Liquid Chromatography Quadrupole Time-of-Flight Mass Spectrometry (LC-Q-TOF/MS). The zeta potential and morphological parameters of the niosomal vesicles were determined through Dynamic Light Scattering (DLS) and Transmission Electron Microscopy (TEM). In vitro assessments of cell viability and apoptosis were conducted on MUC-1 positive HeLa cells and MUC-1 negative U87 cells. RESULTS: The findings confirmed the successful conjugation of Dox and Cis within the niosomes. The Nio/Dox-Cis/MUC-1 formulation demonstrated enhanced efficacy compared to the individual drugs and their unencapsulated combination in both cell lines. Notably, the Nio/Dox-Cis/MUC-1 formulation exhibited greater effectiveness on HeLa cells (38.503 ± 1.407) than on U87 cells (46.653 ± 1.297). CONCLUSION: The study underscores the potential of the Dox-Cis conjugate as a promising strategy for cancer treatment, particularly through platforms that facilitate targeted drug delivery to cancer cells. This targeted approach could lead to more effective and personalized cancer therapies.


Assuntos
Aptâmeros de Nucleotídeos , Sobrevivência Celular , Cisplatino , Doxorrubicina , Lipossomos , Mucina-1 , Humanos , Doxorrubicina/farmacologia , Doxorrubicina/química , Mucina-1/metabolismo , Mucina-1/química , Lipossomos/química , Cisplatino/farmacologia , Cisplatino/química , Aptâmeros de Nucleotídeos/química , Aptâmeros de Nucleotídeos/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Apoptose/efeitos dos fármacos , Linhagem Celular Tumoral , Células HeLa , Protocolos de Quimioterapia Combinada Antineoplásica/farmacologia , Antineoplásicos/farmacologia , Antineoplásicos/química , Composição de Medicamentos/métodos
4.
Anal Chim Acta ; 1306: 342617, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692789

RESUMO

BACKGROUND: Alpha-fetoprotein (AFP) is a fetal protein that can indicate congenital anomalies such as Down syndrome and spinal canal blockage when detected at abnormal levels in pregnant women. Current AFP detection methods rely on invasive blood or serum samples, which require sophisticated equipment. From the many solutions proposed, colorimetric paper-based assays excel in point-of-care settings. The concept of paper-based ELISA (p-ELISA) enhances traditional methods, aligning with the ASSURED criteria for diagnostics in resource-limited regions. Despite success in microfluidic paper-based assay devices, laser printing remains underexplored for p-ELISA. Additionally, modifying the paper surface provides an additional layer of sensitivity enhancement. RESULTS: In this study, we developed a novel laser-printed paper-based ELISA (LP-pELISA) for rapid, sensitive, and noninvasive detection of AFP in saliva samples. The LP-pELISA platform was fabricated by printing hydrophobic barriers on filter paper using a laser printer, followed by depositing hydroxyapatite (HAp) as an immobilization material for the antibodies. The colorimetric detection was achieved using AuNPs functionalized with anti-AFP antibodies and silver nitrate enhancement. The LP-pELISA exhibited a linear response for AFP detection in both buffer and saliva samples over a range of 1.0-800 ng mL-1, with a limit of detection (LOD) reaching 1.0 ng mL-1. The assay also demonstrated good selectivity, repeatability, reproducibility, and stability. The LP-pELISA was further validated by testing spiked human saliva samples, showing its potential for point-of-care diagnosis of congenital disabilities. SIGNIFICANCE: The LP-pELISA is a noninvasive platform showcasing simplicity, cost-effectiveness, and user-friendliness, utilizing laser printing, hydroxyapatite modification, and saliva samples to efficiently detect AFP. Beyond its application for AFP, this method's versatility extends to other biomarkers, positioning it as a catalyst for the evolution of paper-based biosensors. The LP-pELISA holds promise as a transformative tool for point-of-care diagnostics, fostering advancements in healthcare with its innovative technology.


Assuntos
Colorimetria , Durapatita , Ensaio de Imunoadsorção Enzimática , Lasers , Papel , Saliva , alfa-Fetoproteínas , Humanos , Saliva/química , Durapatita/química , alfa-Fetoproteínas/análise , Impressão , Ouro/química , Limite de Detecção , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química
5.
Biosensors (Basel) ; 13(9)2023 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-37754085

RESUMO

Here, we report magnetic nanoparticle-based biosensor platforms for the rapid detection of SARS-CoV-2 antibody responses in human serum. The use of the proposed system enabled the detection of anti-SARS-CoV-2 spike (S) and nucleocapsid (N) proteins at a concentration of ng/mL in both buffer and real serum samples. In particular, the protocol, which is considered an indicator of innate immunity after vaccination or post-infection, could be useful for the evaluation of antibody response. We included a total of 48 volunteers who either had COVID-19 but were not vaccinated or who had COVID-19 and were vaccinated with CoronoVac or Biontech. Briefly, in this study, which was planned as a cohort, serum samples were examined 3, 6, and 12 months from the time the volunteers' showed symptoms of COVID-19 with respect to antibody response in the proposed system. Anti-S Ab and anti-N Ab were detected with a limit of detection of 0.98 and 0.89 ng/mL, respectively. These data were confirmed with the corresponding commercial an electrochemiluminescence immunoassay (ECLIA) assays. Compared with ECLIA, more stable data were obtained, especially for samples collected over 6 months. After this period, a drop in the antibody responses was observed. Our findings showed that it could be a useful platform for exploring the dynamics of the immune response, and the proposed system has translational use potential for the clinic. In conclusion, the MNP-based biosensor platform proposed in this study, together with its counterparts in previous studies, is a candidate for determining natural immunity and post-vaccination antibody response, as well as reducing the workload of medical personnel and paving the way for screening studies on vaccine efficacy.


Assuntos
COVID-19 , Nanopartículas de Magnetita , Humanos , Formação de Anticorpos , SARS-CoV-2 , COVID-19/diagnóstico , Anticorpos Antivirais
6.
J Pharm Biomed Anal ; 235: 115623, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37542827

RESUMO

Nanomaterials and nanotechnology offer promising opportunities in point-of-care (POC) diagnostics and therapeutics due to their unique physical and chemical properties. POC platforms aim to provide rapid and portable diagnostic and therapeutic capabilities at the site of patient care, offering cost-effective solutions. Incorporating nanomaterials with distinct optical, electrical, and magnetic properties can revolutionize the POC industry, significantly enhancing the effectiveness and efficiency of diagnostic and theragnostic devices. By leveraging nanoparticles and nanofibers in POC devices, nanomaterials have the potential to improve the accuracy and speed of diagnostic tests, making them more practical for POC settings. Technological advancements, such as smartphone integration, imagery instruments, and attachments, complement and expand the application scope of POCs, reducing invasiveness by enabling analysis of various matrices like saliva and breath. These integrated testing platforms facilitate procedures without compromising diagnosis quality. This review provides a summary of recent trends in POC technologies utilizing nanomaterials and nanotechnologies for analyzing disease biomarkers. It highlights advances in device development, nanomaterial design, and their applications in POC. Additionally, complementary tools used in POC and nanomaterials are discussed, followed by critical analysis of challenges and future directions for these technologies.


Assuntos
Nanoestruturas , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Testes Imediatos , Nanoestruturas/química , Nanotecnologia/métodos , Saliva
7.
ACS Appl Mater Interfaces ; 15(31): 37247-37258, 2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37499237

RESUMO

Recently, illicit drug use has become more widespread and is linked to problems with crime and public health. These drugs disrupt consciousness, affecting perceptions and feelings. Combining stimulants and depressants to suppress the effect of drugs has become the most common reason for drug overdose deaths. On-site platforms for illicit-drug detection have gained an important role in dealing, without any excess equipment, long process, and training, with drug abuse and drug trafficking. Consequently, the development of rapid, sensitive, noninvasive, and reliable multiplex drug-detecting platforms has become a major necessity. In this study, a multiplex laser-scribed graphene (LSG) sensing platform with one counter, one reference, and three working electrodes was developed for rapid and sensitive electrochemical detection of amphetamine (AMP), cocaine (COC), and benzodiazepine (BZD) simultaneously in saliva samples. The multidetection sensing system was combined with a custom-made potentiostat to achieve a complete point-of-care (POC) platform. Smartphone integration was achieved by a customized application to operate, display, and send data. To the best of our knowledge, this is the first multiplex LSG-based electrochemical platform designed for illicit-drug detection with a custom-made potentiostat device to build a complete POC platform. Each working electrode was optimized with standard solutions of AMP, COC, and BZD in the concentration range of 1.0 pg/mL-500 ng/mL. The detection limit of each illicit drug was calculated as 4.3 ng/mL for AMP, 9.7 ng/mL for BZD, and 9.0 ng/mL for COC. Healthy and MET (methamphetamine) patient saliva samples were used for the clinical study. The multiplex LSG sensor was able to detect target analytes in real saliva samples successfully. This multiplex detection device serves the role of a practical and affordable alternative to conventional drug-detection methods by combining multiple drug detections in one portable platform.


Assuntos
Estimulantes do Sistema Nervoso Central , Cocaína , Drogas Ilícitas , Metanfetamina , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Monitoramento de Medicamentos
8.
ACS Appl Mater Interfaces ; 15(20): 24109-24119, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37184103

RESUMO

Multifunctional electrospun nanofibers (ENs) with improved properties have increased attention nowadays. Their insoluble forms in water with decreased hydrophobicity are desired for the immobilization of biological molecules. Also, the addition of functional groups on the backbone provides the conjugation of biomolecules onto the surface of ENs via covalent bonds to increase their stability. Here, poly(vinylidene fluoride) (PVDF) was chosen to prepare a platform, which is insoluble in water, and polyethylenimine (PEI) was used to add amine groups on the surface of ENs to bind biological molecules via covalent conjugation. So, PVDF-PEI nanofibers were prepared on a glassy carbon electrode to immobilize an antimethamphetamine antibody (Anti-METH) as a model biomolecule. The obtained PVDF-PEI/Anti-METH was used for the bioelectrochemical detection of methamphetamine (METH), a common illicit drug. Bioelectrochemical detection of METH on PVDF-PEI/Anti-METH-coated electrodes was carried out by voltammetry in the range of 2.0-50 ng/mL METH. Moreover, the effect of dansyl chloride (DNC) derivatization of METH on the sensitivity of PVDF-PEI/Anti-METH was tested. Finally, METH analysis was carried out in synthetic body fluids. The obtained results showed that PVDF-PEI ENs can be adopted as an immobilization matrix for the biorecognition elements of biobased detection systems, and the derivative of METH (METH-DNC) increased the sensitivity of PVDF-PEI/Anti-METH.


Assuntos
Imunoconjugados , Metanfetamina , Nanofibras , Nanofibras/química , Polivinil/química , Anticorpos
9.
Biosensors (Basel) ; 13(3)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36979600

RESUMO

Microfluidics is very crucial in lab-on-a-chip systems for carrying out operations in a large-scale laboratory environment on a single chip. Microfluidic systems are miniaturized devices in which the fluid behavior and control can be manipulated on a small platform, with surface forces on the platform being greater than volumetric forces depending on the test method used. In recent years, paper-based microfluidic analytical devices (µPADs) have been developed to be used in point-of-care (POC) technologies. µPADs have numerous advantages, including ease of use, low cost, capillary action liquid transfer without the need for power, the ability to store reagents in active form in the fiber network, and the capability to perform multiple tests using various measurement techniques. These benefits are critical in the advancement of paper-based microfluidics in the fields of disease diagnosis, drug application, and environment and food safety. Cancer is one of the most critical diseases for early detection all around the world. Detecting cancer-specific biomarkers provides significant data for both early diagnosis and controlling the disease progression. µPADs for cancer biomarker detection hold great promise for improving cure rates, quality of life, and minimizing treatment costs. Although various types of bioanalytical platforms are available for the detection of cancer biomarkers, there are limited studies and critical reviews on paper-based microfluidic platforms in the literature. Hence, this article aims to draw attention to these gaps in the literature as well as the features that future platforms should have.


Assuntos
Técnicas Analíticas Microfluídicas , Neoplasias , Humanos , Microfluídica , Sistemas Automatizados de Assistência Junto ao Leito , Detecção Precoce de Câncer , Qualidade de Vida , Papel , Biomarcadores Tumorais , Neoplasias/diagnóstico , Dispositivos Lab-On-A-Chip
10.
Biosensors (Basel) ; 13(3)2023 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-36979612

RESUMO

Minimally invasive approaches for cancer diagnosis are an integral step in the quest to improve cancer survival. Liquid biopsies such as blood samples are matrices explored to extract valuable information about the tumor and its state through various indicators, such as proteins, peptides, tumor DNA, or circulating tumor cells. Although these markers are scarce, making their isolation and detection in complex matrices challenging, the development in polymer chemistry producing interesting structures, including molecularly imprinted polymers, branched polymers, nanopolymer composites, and hybrids, allowed the development of enhanced platforms with impressive performance for liquid biopsies analysis. This review describes the latest advances and developments in polymer synthesis and their application for minimally invasive cancer diagnosis. The polymer structures improve the operational performances of biosensors through various processes, such as increased affinity for enhanced sensitivity, improved binding, and avoidance of non-specific interactions for enhanced specificity. Furthermore, polymer-based materials can be a tremendous help in signal amplification of usually low-concentrated targets in the sample. The pros and cons of these materials, how the synthesis process affects their performance, and the device applications for liquid biopsies diagnosis will be critically reviewed to show the essentiality of this technology in oncology and clinical biomedicine.


Assuntos
Neoplasias , Humanos , Biópsia Líquida , Neoplasias/diagnóstico , Neoplasias/patologia , DNA , Polímeros/química , Proteínas
11.
ACS Appl Bio Mater ; 6(4): 1368-1379, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-36926800

RESUMO

Integrating electronic applications with paper, placed next to or below printed images or graphics, can further expand the possible uses of paper substrates. Consuming paper as a substrate in the field of electronics can lead to significant innovations toward papertronics applications as paper comprises various advantages like being disposable, inexpensive, biodegradable, easy to handle, simple to use, and easily available. All of these advantages will definitely spur the advancement of the electronics field, but unfortunately, putting electronics on paper is not an easy task because, compared to plastics, the paper surface is not just rough but also porous. For example, in the case of lateral flow assay testing the sensor response is delayed if the pore size of the paper is enormous. This might be a disadvantage for most electrical devices printed directly on paper. Still, some methods make it compatible when fit with a rough, absorbent surface of the paper. Building electronic devices on a standard paper substrate have sparked much interest because of its lightweight, environmental friendliness, minimal cost, and simple fabrication. A slew of improvements have been achieved in recent years to make paper electronics perform better in various applications, including transistors, batteries, and displays. In addition, flexible electronics have gained much interest in human-machine interaction and wireless sensing. This review briefly examines the origins and fabrication of paper electronics and then moves on to applications and exciting possible paths for paper-based electronics.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Região de Recursos Limitados , Eletrônica , Fontes de Energia Elétrica
12.
Talanta ; 254: 124166, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36493566

RESUMO

A facile amperometric biosensor that included oxidase mimicking Co/2Fe metal-organic framework (MOF) for sialic acid (SA) detection was prepared. Amperometric SA biosensor was constructed on a gold screen-printed electrode via immobilization of Co/2Fe MOF and N-acetylneuraminic Acid Aldolase (NANA-Aldolase) enzyme, respectively. NANA-Aldolase enzyme converts free SA into pyruvate and N-acetyl-d-mannosamine. After this conversion, oxidase mimicking Co/2Fe bimetallic MOF converts pyruvate into acetylphosphate and O2 into H2O2. Investigation of analytical characteristics resulted with the linear range of 0.02 mM-1.00 mM of SA concentration with limit of detection value of 0.026 mM. Sample application studies with developed SA biosensor were carried out with GD3 ganglioside and HeLa cancer cell lines which have high SA concentrations while A549 cell lines were also used as control group. Before detecting free SA, the bound SA was freed from SA sources where every step was monitored via electron impedance spectroscopy. Then, free SA was successfully detected with the amperometric SA biosensor and as a result, more practical and accurate system was developed.


Assuntos
Técnicas Biossensoriais , Estruturas Metalorgânicas , Oxirredutases , Ácido N-Acetilneuramínico , Enzimas Imobilizadas/química , Peróxido de Hidrogênio/química , Técnicas Biossensoriais/métodos , Ácido Pirúvico , Limite de Detecção , Eletrodos
13.
Artigo em Inglês | MEDLINE | ID: mdl-36315467

RESUMO

The use of porous materials as the core for synthesizing molecularly imprinted polymers (MIPs) adds significant value to the resulting sensing system. This review covers in detail the current progress and achievements regarding the synergistic combination of MIPs and porous materials, namely metal/covalent-organic frameworks (MOFs/COFs), including the application of such frameworks in the development of upgraded sensor platforms. The different processes involved in the synthesis of MOF/COF-MIPs are outlined, along with their intrinsic properties. Special attention is paid to debriefing the impact of the morphological changes that occur through the synergistic combination compared to those that occur due to the individual entities. Thereafter, the strategies used for building the sensors, as well as the transduction modes, are overviewed and discussed. This is followed by a full description of research advances for various types of MOF/COF-MIP-based (bio)sensors and their applications in the fields of environmental monitoring, food safety, and pharmaceutical analysis. Finally, the challenges/drawbacks, as well as the prospects of this research field, are discussed in detail.

14.
Biosensors (Basel) ; 12(9)2022 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-36140121

RESUMO

Diagnostic biomarkers based on epigenetic changes such as DNA methylation are promising tools for early cancer diagnosis. However, there are significant difficulties in directly and specifically detecting methylated DNA regions. Here, we report an electrochemical sensing system based on magnetic nanoparticles that enable a quantitative and selective analysis of the methylated septin9 (mSEPT9) gene, which is considered a diagnostic marker in early stage colorectal cancer (CRC). Methylation levels of SEPT9 in CRC samples were successfully followed by the selective recognition ability of a related peptide nucleic acid (PNA) after hybridization with DNA fragments in human patients' serums and plasma (n = 10). Moreover, this system was also adapted into a point-of-care (POC) device for a one-step detection platform. The detection of mSEPT9 demonstrated a limit of detection (LOD) value of 0.37% and interference-free measurement in the presence of branched-chain amino acid transaminase 1 (BCAT1) and SRY box transcription factor 21 antisense divergent transcript 1 (SOX21-AS1). The currently proposed functional platform has substantial prospects in translational applications of early CRC detection.


Assuntos
Neoplasias Colorretais , Nanopartículas de Magnetita , Ácidos Nucleicos Peptídicos , Aminoácidos de Cadeia Ramificada , Biomarcadores Tumorais , Neoplasias Colorretais/diagnóstico , DNA , Detecção Precoce de Câncer , Compostos Ferrosos , Humanos , Metalocenos , Septinas/genética , Septinas/metabolismo , Transaminases/metabolismo , Fatores de Transcrição/metabolismo
15.
Biosens Bioelectron ; 216: 114680, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36113389

RESUMO

Cardiovascular diseases (CVDs) are the number one cause of death worldwide, taking 17.9 million lives each year. The rapid, sensitive, and accurate determination of cardiac biomarkers is vital for the timely diagnosis of CVDs. For accurate diagnosis, dependence on a single biomarker is unreliable because each one has also been linked to other diseases. To overcome this problem, the multiplexed determination of two or more markers has emerged as a promising alternative to single-marker analysis. Over the last 5 years, research interest in the development of biosensors for targeting multiple cardiac markers has increased. In this study, we critically reviewed the various multiplexed biosensing approaches reported during the last 5 years, categorizing them by signal readouts. Prospective detection configurations, capture probes, electrode design strategies, electrode types, nanomaterials, reporter tags, and assay types were reviewed, tabulated, and critically discussed. Then, their advantages and limitations were highlighted. For each category, we provided our perspective as well as the overall critical discussion. Lastly, we summarized potential commercial multiplexed cardiac biosensors and commented on the challenges and future prospects for such sensors.


Assuntos
Técnicas Biossensoriais , Doenças Cardiovasculares , Nanoestruturas , Biomarcadores , Técnicas Biossensoriais/métodos , Doenças Cardiovasculares/diagnóstico , Humanos , Estudos Prospectivos
16.
Biosensors (Basel) ; 12(8)2022 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-36004979

RESUMO

Many emerging technologies have the potential to improve health care by providing more personalized approaches or early diagnostic methods. In this review, we cover smartphone-based multiplexed sensors as affordable and portable sensing platforms for point-of-care devices. Multiplexing has been gaining attention recently for clinical diagnosis considering certain diseases require analysis of complex biological networks instead of single-marker analysis. Smartphones offer tremendous possibilities for on-site detection analysis due to their portability, high accessibility, fast sample processing, and robust imaging capabilities. Straightforward digital analysis and convenient user interfaces support networked health care systems and individualized health monitoring. Detailed biomarker profiling provides fast and accurate analysis for disease diagnosis for limited sample volume collection. Here, multiplexed smartphone-based assays with optical and electrochemical components are covered. Possible wireless or wired communication actuators and portable and wearable sensing integration for various sensing applications are discussed. The crucial features and the weaknesses of these devices are critically evaluated.


Assuntos
Técnicas Biossensoriais , Smartphone , Biomarcadores/análise , Técnicas Biossensoriais/métodos , Atenção à Saúde , Sistemas Automatizados de Assistência Junto ao Leito
17.
Phytochem Anal ; 33(7): 1058-1067, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35795911

RESUMO

INTRODUCTION: The chronicity of advanced glycation end-products (AGEs) imparts various damages resulting in metabolic dysfunction and diseases involving inflammation and oxidative stress. The use of plant extracts is of high interest in complementary medicine. Yet, extracts are multicomponent mixtures, and difficult to pinpoint their exact mechanism. OBJECTIVES: We hypothesise that network pharmacology and bioinformatics can help experimental findings depict the exact active components and mechanism of action by which they induce their effects. Additionally, the toxicity and variability can be lowered and standardised with proper encapsulation methods. METHODOLOGY: Here, we propose the formulation of phytoniosomes encapsulating two Artemisia species (Artemisia dracunculus and Artemisia absinthium) to mitigate AGEs and their induced cell redox dysregulation in the liver. Extracts from different solvents were identified via liquid chromatography quadrupole time-of-flight mass spectrometry (LC-Q-TOF-MS/MS). Phytoniosomes were explored for their anti-glycating effect and modulation of AGE-induced damages in THLE-2 liver cells. Network pharmacology tools were used to identify possible targets and signalling pathways implicated. RESULTS: Data demonstrated that A. absinthium phytoniosomes had a significant anti-AGE effect comparable to reference molecules and higher than A. dracunculus. They were able to restore cell dysfunction through the restoration of tumour necrosis alpha (TNF-α), interleukin 6 (IL-6), nitric oxide, and total antioxidant capacity. Phytoniosomes were able to protect cells from apoptosis by decreasing caspase 3 activity. Network pharmacology and bioinformatic analysis confirmed the induction of the effect via Akt-PI3K-MAPK and AGE-RAGE signalling pathways through quercetin and luteolin actions. CONCLUSION: The current report highlights the potential of Artemisia phytoniosomes as strong contenders in AGE-related disease therapy.


Assuntos
Artemisia , Diabetes Mellitus , Medicamentos de Ervas Chinesas , Antioxidantes/farmacologia , Artemisia/química , Caspase 3 , Cromatografia Líquida , Interleucina-6 , Fígado/metabolismo , Luteolina , Farmacologia em Rede , Óxido Nítrico , Fosfatidilinositol 3-Quinases , Extratos Vegetais/química , Extratos Vegetais/farmacologia , Proteínas Proto-Oncogênicas c-akt/metabolismo , Quercetina , Solventes , Espectrometria de Massas em Tandem/métodos , Fator de Necrose Tumoral alfa
18.
Biosensors (Basel) ; 12(5)2022 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-35624602

RESUMO

The evolution of biosensors and diagnostic devices has been thriving in its ability to provide reliable tools with simplified operation steps. These evolutions have paved the way for further advances in sensing materials, strategies, and device structures. Polymeric composite materials can be formed into nanostructures and networks of different types, including hydrogels, vesicles, dendrimers, molecularly imprinted polymers (MIP), etc. Due to their biocompatibility, flexibility, and low prices, they are promising tools for future lab-on-chip devices as both manufacturing materials and immobilization surfaces. Polymers can also allow the construction of scaffold materials and 3D structures that further elevate the sensing capabilities of traditional 2D biosensors. This review discusses the latest developments in nano-scaled materials and synthesis techniques for polymer structures and their integration into sensing applications by highlighting their various structural advantages in producing highly sensitive tools that rival bench-top instruments. The developments in material design open a new door for decentralized medicine and public protection that allows effective onsite and point-of-care diagnostics.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Técnicas Biossensoriais/métodos , Nanoestruturas/química , Polímeros/química
19.
Mol Cell Biochem ; 477(10): 2345-2357, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35543857

RESUMO

Artemisia herba-alba (AHA) is a traditionally used plant to treat various diseases, including diabetes and metabolic dysfunctions. Plant extracts are generally explored empirically without a deeper assessment of their mechanism of action. Here, we describe a combinatorial study of biochemical, molecular, and bioinformatic (metabolite-protein pharmacology network) analyses to elucidate the mechanism of action of AHA and shed light on its multilevel effects in the treatment of diabetes-related advanced glycation end-products (AGE)-induced liver damages. The extract's polyphenols and flavonoids content were measured and then identified via LC-Q-TOF-MS/MS. Active compounds were used to generate a metabolite-target interaction network via Swiss Target Prediction and other databases. The extract was tested for its antiglycation and aggregation properties. Next, THLE-2 liver cells were challenged with AGEs, and the mechanistic markers were measured [TNF-α, IL-6, nitric oxide, total antioxidant capacity, lipid peroxidation (LPO), and caspase 3]. Metabolite and network screening showed the involvement of AHA in diabetes, glycation, liver diseases, aging, and apoptosis. Experimental confirmation showed that AHA inhibited protein modification and AGE formation. Additionally, AHA reduced inflammatory mediators (IL-6, TNFα), oxidative stress markers (NO, LPO), and apoptosis (Caspase 3). On the other hand, cellular total antioxidant capacity was restored to normal levels. The combinatorial study showed that AHA regulates AGE-induced liver damages through MAPK-AKT and AGE-RAGE signaling pathways. This report highlights the combination of experimental and network pharmacology for the exact elucidation of AHA mechanism of action as a multitarget option in the therapy of diabetes and AGEs-related diseases.


Assuntos
Artemisia , Diabetes Mellitus , Antioxidantes/farmacologia , Artemisia/metabolismo , Caspase 3/metabolismo , Diabetes Mellitus/tratamento farmacológico , Flavonoides/farmacologia , Produtos Finais de Glicação Avançada/metabolismo , Mediadores da Inflamação/metabolismo , Interleucina-6/metabolismo , Fígado/metabolismo , Óxido Nítrico/metabolismo , Extratos Vegetais/farmacologia , Polifenóis/farmacologia , Proteínas Proto-Oncogênicas c-akt/metabolismo , Receptor para Produtos Finais de Glicação Avançada/metabolismo , Transdução de Sinais , Espectrometria de Massas em Tandem , Fator de Necrose Tumoral alfa/metabolismo
20.
Mikrochim Acta ; 189(5): 202, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35474492

RESUMO

The construction of a rapid and easy immunofluorescence bioassay for SARS-CoV-2 detection is described. We report for the first time a novel one-pot synthetic approach for simultaneous photoinduced step-growth polymerization of pyrene (Py) and ring-opening polymerization of ε-caprolactone (PCL) to produce a graft fluorescent copolymer PPy-g-PCL that was conjugated to SARS-CoV-2-specific antibodies using EDC/NHS chemistry. The synthesis steps and conjugation products were fully characterized using standard spectral analysis. Next, the PPy-g-PCL was used for the construction of a dot-blot assay which was calibrated for applications to human nasopharyngeal samples. The analytical features of the proposed sensor showed a detection range of 6.03-8.7 LOG viral copy mL-1 (Ct Scores: 8-25), the limit of detection (LOD), and quantification (LOQ) of 1.84 and 6.16 LOG viral copy mL-1, respectively. The repeatability and reproducibility of the platform had a coefficient of variation (CV) ranging between 1.2 and 5.9%. The fluorescence-based dot-blot assay was tested with human samples. Significant differences were observed between the fluorescence intensity of the negative and positive samples, with an overall correct response of 93.33%. The assay demonstrated a high correlation with RT-PCR data. This strategy opens new insights into simplified synthesis procedures of the reporter molecules and their high potential sensing and diagnosis applications.


Assuntos
COVID-19 , SARS-CoV-2 , Bioensaio , COVID-19/diagnóstico , Caproatos , Corantes , Humanos , Lactonas , Poli A , Poliésteres , Polimerização , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA