Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Aviat Space Environ Med ; 83(10): 929-34, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23066613

RESUMO

INTRODUCTION: Medical knowledge of the human body in microgravity and hypergravity is based upon studies of healthy individuals well-conditioned for such environments. Little data exist regarding the effects of spaceflight on untrained commercial passengers. We examined the responses of potential spaceflight participants (SFP) to centrifuge G-force exposure. METHODS: There were 77 individuals (65 men, 12 women), 22-88 yr old, who underwent 6 centrifuge runs over 48 h. Day 1 consisted of two +Gz runs (peak = 3.5+Gz, run 2) and two +Gx runs (peak = 6.0+Gx, run 4). Day 2 consisted of two runs approximating a suborbital spaceflight profile. Data included blood pressure, electrocardiogram, and postrun questionnaires regarding motion sickness, disorientation, greyout, and other symptoms. RESULTS: Of the 77 participants, average age was 50.4 +/- 12.7 yr. Average heart rate (HR) varied by sex and direction of G-exposure (+Gz: F 150 +/- 19, M 123 +/- 27; +Gx: F 135 +/- 30, M 110 +/- 27). Age and peak HR were inversely related (HR < 120 bpm: 60.2 +/- 12.2 yr, HR > 120: 47.1 +/- 10.9 yr). HR during peak G-exposure for the final run was associated with post-run imbalance (no imbalance: HR 126 +/- 26, imbalance: HR 145 +/- 21); no other significant hemodynamic change, sex, or age variation was associated with imbalance. Age and greyout were inversely associated; there was no association between greyout and vital sign change, sex, or G-force magnitude. Baseline/pretrial mean arterial pressure (MAP) was not associated with any symptoms. DISCUSSION: The results suggest that most individuals with well-controlled medical conditions can withstand acceleration forces involved in launch/landing profiles of commercial spaceflight vehicles. Further investigation will help refine which conditions present significant risk during suborbital flight and beyond.


Assuntos
Aceleração/efeitos adversos , Hipergravidade/efeitos adversos , Voo Espacial , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Confusão/etiologia , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Enjoo devido ao Movimento/etiologia , Equilíbrio Postural , Inquéritos e Questionários , Síncope/etiologia , Viagem , Adulto Jovem
2.
Rev Sci Instrum ; 78(5): 055107, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17552860

RESUMO

We present the performance characteristics of a time-of-flight secondary ion mass spectrometer designed for 157 nm laser postionization of sputtered neutrals for high sensitivity elemental and isotopic analyses. The instrument was built with the aim of analyzing rare element abundances in micron to submicron samples such as interstellar grains and cometary dust. Relative sensitivity factors have been determined for secondary ion mass spectrometry which show an exponential dependency against the first ionization potential. This allows elemental abundances to be measured with errors below 25% for most major elements. The accuracy for isotope ratios, where isotopes can be resolved from isobaric interferences, is usually limited only by counting statistics. In laser secondary neutral mass spectrometry, the spatial and temporal overlaps between the laser and sputtered neutral atoms are modeled and predictions of total detection efficiency and isotopic and elemental fractionation are compared with experimental data. Relative sensitivity factors for laser-ionized secondary neutrals from a stainless steel standard are found to vary less than 3% above saturation laser pulse energy enabling more accurate quantification.


Assuntos
Poeira Cósmica/análise , Lasers , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...