Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Thorac Cardiovasc Surg ; 29(5): 233-240, 2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-36935120

RESUMO

PURPOSE: Structural valve deterioration (SVD) remains a limitation on the use of bioprosthetic valves, with patient and valve-related factors contributing to early SVD. The Trifecta valve has been reported to have excellent hemodynamics but studies have highlighted early failure. We present a review and case series at a New Zealand tertiary hospital defining early SVD as failure within 3 years of implant. METHODS: A retrospective review from January 2015 to July 2019 included 525 patients undergoing surgical aortic valve replacement with 263 patients receiving an Abbott Trifecta or Trifecta Glide Technology (GT) valve. Our review found an acceptable safety profile for the valve with excellent hemodynamics, with a low mortality, stroke, and permanent pacemaker rate. RESULTS: Three patients out of 263 were identified from the study period as having early SVD requiring reintervention within 3 years of valve implantation leading to a 1.14% failure rate. One of the valves that had early SVD was a new generation Trifecta GT. An additional four patients were identified to have valves implanted prior to the study period and had valve failure at greater than 3 years post implantation. Five cases had cusp tears as their mechanism of failure, raising concerns about durability. CONCLUSION: The Trifecta valve has an acceptable safety profile and offers good hemodynamics due to the externally mounted leaflets. However, our experience of early SVD and failure is concerning for valve durability. Further comparison to other bioprosthetic valves and longer term follow-up are required to characterize the mechanism of failures.

2.
J Card Surg ; 37(12): 5243-5253, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36317394

RESUMO

BACKGROUND: With guidelines progressively recommending bioprosthetic aortic valves in younger patients, a greater emphasis is placed on structural valve deterioration (SVD) as an important clinical endpoint for both transcatheter and surgically implanted valves. However, SVD of bioprosthetic valves is a complex entity with varying definitions in the literature and a multifaceted pathogenesis. AIM: This review first aims to establish the most updated definitions of SVD as per the literature. We then explore the patient- and valve-related factors that play the greatest roles in facilitating early SVD. METHODS: A PubMed literature review was conducted to identify the relevant research in this field within the past two decades. CONCLUSION: Increasing rates of obesity and metabolic syndrome pose a significant risk to the longevity of bioprosthetic valves. Additionally, externally mounted valves have proven to sacrifice durability for superior haemodynamics. Bioprosthetic SVD continues to be a multifactorial issue that will require various patient- and valve-related factors to be addressed.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Falha de Prótese , Valva Aórtica/cirurgia , Desenho de Prótese , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...