Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 87(2): 02A702, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931920

RESUMO

To demonstrate a Mixed Axial and Radial field System (MARS) as the best magnet scheme for future ECRISs, MARS-D, a demonstrative ECRIS using a NbTi MARS magnet is progressing at Lawrence Berkeley National Laboratory. An optimized MARS design can use either NbTi or Nb3Sn coils with reduced engineering complexities to construct the needed high-field magnets. The optimized magnet design could enhance MARS-D to a next generation ECRIS by producing minimum-B field maxima of 5.6 T axially and 3.2 T radially for operating frequencies up to 45 GHz. In-progress test winding has achieved a milestone demonstrating the fabrication feasibility of a MARS closed-loop coil.

2.
Rev Sci Instrum ; 87(2): 02A736, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931954

RESUMO

The long-term operation of high charge state electron cyclotron resonance ion sources fed with high microwave power has caused damage to the plasma chamber wall in several laboratories. Porosity, or a small hole, can be progressively created in the chamber wall which can destroy the plasma chamber over a few year time scale. A burnout of the VENUS plasma chamber is investigated in which the hole formation in relation to the local hot electron power density is studied. First, the results of a simple model assuming that hot electrons are fully magnetized and strictly following magnetic field lines are presented. The model qualitatively reproduces the experimental traces left by the plasma on the wall. However, it is too crude to reproduce the localized electron power density for creating a hole in the chamber wall. Second, the results of a Monte Carlo simulation, following a population of scattering hot electrons, indicate a localized high power deposited to the chamber wall consistent with the hole formation process. Finally, a hypervapotron cooling scheme is proposed to mitigate the hole formation in electron cyclotron resonance plasma chamber wall.

3.
Rev Sci Instrum ; 85(2): 02A922, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593501

RESUMO

A new superconducting Electron Cyclotron Resonance Ion Source (ECRIS) is under development at LBNL to harness the winding techniques of a closed-loop sextupole coil for the next generation ECRIS and to enhance the capability of the 88-in. cyclotron facility. The proposed ECRIS will use a superconducting closed-loop sextupole coil to produce the radial field and a substantial portion of the axial field. The field strengths of the injection, central and extraction regions are adjusted by a three solenoids outside the closed-loop sextupole coil. In addition to maintaining the typical ECRIS magnetic field configuration, this new source will also be able to produce a dustpan-like minimum-B field to explore possible ECRIS performance enhancement. The dustpan-like minimum-B field configuration has about the same strengths for the maximum axial field at the injection region and the maximum radial pole fields at the plasma chamber walls but it can be substantially lower at the extraction region. The dustpan-like minimum-B will have a field maximum Bmax ≥ 2.6 T for operations up to 18 GHz with a ratio of Bmax/Bres ≥ 4 and higher ratios for lower frequencies. The field maxima of this new source can reach over 3 T both at the injection and the plasma chamber walls which could also support operation at 28 GHz. The source will be built of cryogen-free with the magnets directly cooled by cryo-coolers to simplify the cryostat structure. The source design features will be presented and discussed.

4.
Rev Sci Instrum ; 81(2): 02A309, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192330

RESUMO

Electron cyclotron resonance (ECR) ion sources are an essential component of heavy-ion accelerators. Over the past few decades advances in magnet technology and an improved understanding of the ECR ion source plasma physics have led to remarkable performance improvements of ECR ion sources. Currently third generation high field superconducting ECR ion sources operating at frequencies around 28 GHz are the state of the art ion injectors and several devices are either under commissioning or under design around the world. At the same time, the demand for increased intensities of highly charged heavy ions continues to grow, which makes the development of even higher performance ECR ion sources a necessity. To extend ECR ion sources to frequencies well above 28 GHz, new magnet technology will be needed in order to operate at higher field and force levels. The superconducting magnet program at LBNL has been developing high field superconducting magnets for particle accelerators based on Nb(3)Sn superconducting technology for several years. At the moment, Nb(3)Sn is the only practical conductor capable of operating at the 15 T field level in the relevant configurations. Recent design studies have been focused on the possibility of using Nb(3)Sn in the next generation of ECR ion sources. In the past, LBNL has worked on the VENUS ECR, a 28 GHz source with solenoids and a sextupole made with NbTi operating at fields of 6-7 T. VENUS has now been operating since 2004. We present in this paper the design of a Nb(3)Sn ECR ion source optimized to operate at an rf frequency of 56 GHz with conductor peak fields of 13-15 T. Because of the brittleness and strain sensitivity of Nb(3)Sn, particular care is required in the design of the magnet support structure, which must be capable of providing support to the coils without overstressing the conductor. In this paper, we present the main features of the support structure, featuring an external aluminum shell pretensioned with water-pressurized bladders, and we analyze the expected coil stresses with a two-dimensional finite element mechanical model.

5.
Rev Sci Instrum ; 81(2): 02B710, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192450

RESUMO

This paper describes the recent development and commissioning of a pepper-pot emittance meter at the Lawrence Berkeley National Laboratory (LBNL). It is based on a potassium bromide (KBr) scintillator screen in combination with a charged coupled device camera. Pepper-pot scanners record the full four-dimensional transverse phase space emittances which are particularly interesting for electron cyclotron resonance ion sources. The strengths and limitations of evaluating emittances using optical pepper-pot scanners are described and systematic errors induced by the optical data acquisition system will be presented. Light yield tests of KBr exposed to different ion species and first emittance measurement data using ion beams extracted from the 6.4 GHz LBNL electron cyclotron resonance ion source are presented and discussed.

6.
Rev Sci Instrum ; 79(3): 033302, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18377002

RESUMO

High performance electron cyclotron resonance (ECR) ion sources, such as VENUS (Versatile ECR for NUclear Science), produce large amounts of x-rays. By studying their energy spectra, conclusions can be drawn about the electron heating process and the electron confinement. In addition, the bremsstrahlung from the plasma chamber is partly absorbed by the cold mass of the superconducting magnet, adding an extra heat load to the cryostat. Germanium or NaI detectors are generally used for x-ray measurements. Due to the high x-ray flux from the source, the experimental setup to measure bremsstrahlung spectra from ECR ion sources is somewhat different from that for the traditional nuclear physics measurements these detectors are generally used for. In particular, the collimation and background shielding can be problematic. In this paper, we will discuss the experimental setup for such a measurement, the energy calibration and background reduction, the shielding of the detector, and collimation of the x-ray flux. We will present x-ray energy spectra and cryostat heating rates depending on various ion source parameters, such as confinement fields, minimum B-field, rf power, and heating frequency.

7.
Rev Sci Instrum ; 79(2 Pt 2): 02A321, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315111

RESUMO

The concepts and technical challenges related to developing a fourth generation electron cyclotron resonance (ECR) ion source with a rf frequency greater than 40 GHz and magnetic confinement fields greater than twice B(ECR) will be explored in this article. Based on the semiempirical frequency scaling of ECR plasma density with the square of operating frequency, there should be significant gains in performance over current third generation ECR ion sources, which operate at rf frequencies between 20 and 30 GHz. While the third generation ECR ion sources use NbTi superconducting solenoid and sextupole coils, the new sources will need to use different superconducting materials, such as Nb(3)Sn, to reach the required magnetic confinement, which scales linearly with rf frequency. Additional technical challenges include increased bremsstrahlung production, which may increase faster than the plasma density, bremsstrahlung heating of the cold mass, and the availability of high power continuous wave microwave sources at these frequencies. With each generation of ECR ion sources, there are new challenges to be mastered, but the potential for higher performance and reduced cost of the associated accelerator continues to make this a promising avenue for development.

8.
Rev Sci Instrum ; 79(2 Pt 2): 02C710, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315263

RESUMO

The next generation, superconducting electron cyclotron resonance (ECR) ion source VENUS (versatile ECR ion source for nuclear science) started operation with 28 GHz microwave heating in 2004. Since then it has produced world record ion beam intensities. For example, 2850 e microA of O(6+), 200 e microA of U(33+) or U(34+), and in respect to high charge state ions, 1 e microA of Ar(18+), 270 e microA of Ar(16+), 28 e microA of Xe(35+), and 4.9 e microA of U(47+) have been produced. A brief overview of the latest developments leading to these record intensities is given and the production of high intensity uranium beams is discussed in more detail.

9.
Transfusion ; 43(9): 1260-8, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12919429

RESUMO

BACKGROUND: As part of assessing the possibility of transfusion transmission of human herpesvirus 8 (HHV-8 or Kaposi's sarcoma-associated herpesvirus), HHV-8 seroprevalence was estimated among US blood donors, the performance of HHV-8 serologic tests was compared, and the presence of HHV-8 DNA was tested for in donated blood. STUDY DESIGN AND METHODS: Replicate panels of 1040 plasma specimens prepared from 1000 US blood donors (collected in 1994 and 1995) and 21 Kaposi's sarcoma patients were tested for antibodies to HHV-8 in six laboratories. HHV-8 PCR was performed on blood samples from 138 donors, including all 33 who tested seropositive in at least two laboratories and 22 who tested positive in at least one. RESULTS: The estimated HHV-8 seroprevalence among US blood donors was 3.5 percent (95% CI, 1.2%-9.8%) by a conditional dependence latent-class model, 3.0 percent (95% CI, 2.0%-4.6%) by a conditional independence latent-class model, and 3.3 percent (95% CI, 2.3%-4.6%) by use of a consensus-derived gold standard (specimens positive in two or more laboratories); the conditional dependence model best fit the data. In this model, laboratory specificities ranged from 96.6 to 100 percent. Sensitivities ranged widely, but with overlapping 95 percent CIs. HHV-8 DNA was detected in blood from none of 138 donors evaluated. CONCLUSIONS: Medical and behavioral screening does not eliminate HHV-8-seropositive persons from the US blood donor pool, but no viral DNA was found in donor blood. Further studies of much larger numbers of seropositive individuals will be required to more completely assess the rate of viremia and possibility of HHV-8 transfusion transmission. Current data do not indicate a need to screen US blood donors for HHV-8.


Assuntos
Doadores de Sangue/estatística & dados numéricos , Infecções por Herpesviridae/sangue , Infecções por Herpesviridae/epidemiologia , Herpesvirus Humano 8/isolamento & purificação , Anticorpos Antivirais/sangue , Bancos de Sangue/normas , Infecções por Herpesviridae/transmissão , Herpesvirus Humano 8/imunologia , Humanos , Padrões de Referência , Sensibilidade e Especificidade , Estudos Soroepidemiológicos , Estados Unidos/epidemiologia
10.
Transfusion ; 41(10): 1249-57, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11606824

RESUMO

BACKGROUND: CMV DNA screening may be a useful adjunct to serologic tests in distinguishing potentially infectious blood donations from those that are "CMV-safe." However, there is currently no consensus on the optimal assay method for accurate detection of CMV DNA in donors. STUDY DESIGN AND METHODS: A blinded multicenter evaluation of seven CMV PCR assays was performed by five laboratories by using coded sets of analytical controls and donor blood samples. RESULTS: Five assays displayed sufficient sensitivity for donor screening, as judged by consistent detection of a minimum of 25 CMV genome equivalents (geq) in analytical controls constructed to contain from 1 to 100 CMV geq in background DNA from 250,000 cells, while the other two assays displayed inadequate sensitivity. Three sensitive assays, two based on nested PCR directed at the UL93 and UL32 regions of the CMV genome and another test (Monitor Assay, Roche), did not detect CMV DNA in samples from any of 20 pedigreed CMV-seronegative, Western blot-negative (S-/WB-) donors. Two other assays based on nested PCR occasionally detected CMV DNA in S-WB- samples, and one sensitive nested PCR assay directed at UL123 detected CMV DNA in a large proportion (85%) of S-WB- samples. CONCLUSION: Seven CMV PCR assays currently used for research and/or diagnostic applications displayed marked variations in sensitivity, specificity, and reproducibility when applied to coded analytical and clinical control samples containing cellular DNA from the equivalent of 250,000 WBCs. These results will be useful in the selection of assays with performance characteristics appropriate to donor screening objectives. They may also help explain discrepant findings from previous studies that used PCR to determine CMV DNA prevalence in seronegative and seropositive blood donors.


Assuntos
Doadores de Sangue , Citomegalovirus/genética , DNA Viral/sangue , Reação em Cadeia da Polimerase/métodos , Infecções Oportunistas Relacionadas com a AIDS/diagnóstico , Infecções Oportunistas Relacionadas com a AIDS/microbiologia , Anticorpos Antivirais/sangue , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/microbiologia , Primers do DNA , Humanos , Programas de Rastreamento , Reação em Cadeia da Polimerase/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...