Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hernia ; 26(2): 525-532, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34599719

RESUMO

PURPOSE: The laparoscopic ventral hernia repair (LVHR) may have a limit of effectiveness, especially in defects greater than 80 cm2, with a higher recurrence rate which contraindicates this technique. The purpose of this study is to analyze the indication of LVHR determining and comparing the recurrence rate according to defect size in two series. METHODS: We analyzed all patients who underwent LVHR between 2007 and 2017. Patients were divided according to the ring size: < o ≥ 80 cm2 into group one (G1) and group two (G2) respectively. In both groups, all three techniques were used: intraperitoneal onlay mesh (IPOM), IPOM with closure of the defect (IPOM plus), and IPOM plus + anterior videoscopic component separation (AVCS). RESULTS: A total of 258 patients underwent LVHR. Mean recurrence rate was 13% in G1 and 24% in G2. A statistically significant difference was found when comparing the IPOM technique among both groups, with a higher recurrence rate when ring size was ≥ 80 cm2 (p < 0.5). However, when comparing recurrence rate in IPOM plus and IPOM plus + AVCS between both groups, no significant differences were observed, yielding a p of 0.51 and 0.63, respectively. CONCLUSION: The IPOM technique has shown a limit of effectiveness in large ventral hernia defects. The combination of techniques (ring closure and AVCS) may be useful to expand the indication for this surgery to larger defects and to reduce the recurrence rate. Prospective randomized studies are required to confirm this trend.


Assuntos
Hérnia Ventral , Herniorrafia , Laparoscopia , Hérnia Ventral/cirurgia , Herniorrafia/métodos , Humanos , Laparoscopia/métodos , Estudos Prospectivos , Recidiva , Telas Cirúrgicas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...