1.
Radiol Phys Technol ; 17(2): 569-577, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38668937

RESUMO

This study aimed to assess the feasibility of a skin marker-less patient setup using a surface-guided radiotherapy (SGRT) system for extremity radiotherapy. Twenty-five patients who underwent radiotherapy to the extremities were included in this retrospective study. The first group consisted of 10 patients and underwent a traditional setup procedure using skin marks and lasers. The second group comprised 15 patients and had a skin marker-less setup procedure that used an SGRT system only. To compare the two setup procedures for setup accuracy, the mean 3D vector shift magnitude was 0.9 mm for the traditional setup procedure and 0.5 mm for the skin marker-less setup procedure (p < 0.01). In addition, SGRT systems have been suggested to improve the accuracy and reproducibility of patient setups and consistently reduce interfractional setup errors. These results indicate that a skin marker-less patient setup procedure using an SGRT system is useful for extremity irradiation.


Assuntos
Extremidades , Lasers , Radioterapia Guiada por Imagem , Humanos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Radioterapia Guiada por Imagem/métodos , Estudos Retrospectivos , Adulto , Pele/efeitos da radiação , Idoso de 80 Anos ou mais , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle
2.
Jpn J Radiol ; 35(12): 760-765, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29039108

RESUMO

PURPOSE: We propose a method of image-guided brachytherapy (IGBT) that combines MRI-based target volume delineation for the first fraction with CT datasets of subsequent fractions, using an automatic, applicator-based co-registration, and report our preliminary experience. MATERIALS AND METHODS: The MRI of the first fraction was used for the first brachytherapy planning. For each subsequent brachytherapy fraction, after the same applicator insertion, a new CT scan with the applicator in place was obtained. The MR image set was registered to the subsequent brachytherapy treatment planning CT using the applicator for rigid body registration. To demonstrate the registration quality, we used here the Dice index as a measurement of tandem delineation overlap between CT and MRI. RESULTS: The median Dice index was 0.879 (range 0.610-0.932), which indicated that the contours on CT and MRI fitted well. With this combination method, the median D90 of HR CTV and the calculated D2 cm3 of the bladder, rectum, and sigmoid in each fraction were 7.2 (4.0-10.4), 5.9 (2.3-7.7), 4.0 (1.9-6.7), and 3.8 (0.6-7.2) Gy, respectively. CONCLUSION: Our described method of MRI-guided IGBT offers a practical option for the benefits of target delineation.


Assuntos
Braquiterapia/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias do Colo do Útero/radioterapia , Fluxo de Trabalho , Colo do Útero/diagnóstico por imagem , Feminino , Humanos , Imagem Multimodal/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
3.
J Radiat Res ; 56(5): 849-55, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26160181

RESUMO

In Japan, cetuximab with concurrent bioradiotherapy (BRT) for squamous cell carcinoma of head and neck (SCCHN) was approved in December 2012. We herein report our initial experience of BRT, with special emphasis on acute toxicities of this combination therapy. Thirty-one non-metastatic SCCHN patients who underwent BRT using cetuximab between July 2013 and June 2014 were retrospectively evaluated. All patients received cetuximab with a loading dose of 400 mg/m(2) one week before the start of radiotherapy, followed by 250 mg/m(2) per week during radiotherapy. The median cycle of cetuximab was seven cycles and the median dose of radiotherapy was 70 Gy. Twenty-five patients (80.6%) accomplished planned radiotherapy and six cycles or more cetuximab administration. Six patients (19.4%) discontinued cetuximab. Grade 3 dermatitis, mucositis and infusion reaction occurred in 19.4%, 48.3% and 3.2%, respectively. One patient experienced Grade 3 gastrointestinal bleeding caused by diverticular hemorrhage during BRT. Grade 3 drug-induced pneumonitis occurred in two patients. The response rate was 74%, including 55% with a complete response. BRT using cetuximab for Japanese patients with SCCHN was feasible as an alternative for cisplatin-based concurrent chemoradiation, although longer follow-up is necessary to evaluate late toxicities.


Assuntos
Antineoplásicos/uso terapêutico , Cetuximab/uso terapêutico , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/radioterapia , Idoso , Idoso de 80 Anos ou mais , Dermatite/etiologia , Seguimentos , Humanos , Japão , Pessoa de Meia-Idade , Mucosite/etiologia , Lesões por Radiação/etiologia , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Resultado do Tratamento
4.
Brachytherapy ; 14(5): 642-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26024785

RESUMO

BACKGROUND AND PURPOSE: To relieve the pain and distress experienced by women who undergo high-dose-rate intracavitary radiotherapy (HDR-ICRT) for cervical cancer and to improve the current status of gynecologic brachytherapy in Japan, a new intravenous anesthetic protocol involving the administration of a combination of propofol and ketamine was developed. The primary aim of this study is to investigate the efficacy and safety of this new anesthetic protocol during HDR-ICRT for cervical cancer. METHODS AND MATERIALS: All the patients who were diagnosed with cervical cancer between December 2008 and February 2011, treated with three-channel brachytherapy and subjected to the new sedation protocol, were evaluated. A visual analog scale (VAS) was used to assess the pain during brachytherapy, and we collected VAS score at the next HDR-ICRT. Toxicities were graded using the Common Toxicity Criteria, version 3. RESULTS: A total of 178 sessions of HDR-ICRT were delivered to 57 patients. The patients' median VAS pain score was 0 (range, 0-10). The most frequent side effect was Grade 1-2 nausea, which occurred in 33 sessions (34%). However, 13 of 14 patients received concurrent cisplatin chemotherapy. None of the patients experienced Grade 3 or 4 adverse events. CONCLUSIONS: We have demonstrated that our new intravenous anesthetic protocol produces appropriate effects and can be performed by radiation oncologists who were required to finish training in basic life support and the cooperative system of emergency according to in-house guideline.


Assuntos
Anestesia Intravenosa , Anestésicos Intravenosos , Braquiterapia/efeitos adversos , Carcinoma/radioterapia , Dor/prevenção & controle , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestesia Intravenosa/efeitos adversos , Antineoplásicos/uso terapêutico , Carcinoma/tratamento farmacológico , Quimiorradioterapia/efeitos adversos , Cisplatino/uso terapêutico , Feminino , Humanos , Japão , Ketamina , Pessoa de Meia-Idade , Dor/etiologia , Medição da Dor , Propofol , Neoplasias do Colo do Útero/tratamento farmacológico
5.
J Radiat Res ; 55(5): 996-1001, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24914103

RESUMO

The purpose of this study was to retrospectively evaluate the incidence of delayed renal dysfunction after total body irradiation (TBI) in long-term survivors of TBI/hematopoietic stem cell transplantation (HSCT). Between 1989 and 2006, 24 pediatric patients underwent TBI as part of the conditioning regimen for HSCT at Chiba University Hospital. Nine patients who survived for more than 5 years were enrolled in this study. No patient had any evidence of renal dysfunction prior to the transplant according to their baseline creatinine levels. The median age at the time of diagnosis was 6 years old (range: 1-17 years old). The follow-up period ranged from 79-170 months (median: 140 months). Renal dysfunction was assessed using the estimated glomerular filtration rate (eGFR). The TBI dose ranged from 8-12 Gy delivered in 3-6 fractions over 2-3 d. The patients were treated with linear accelerators in the supine position, and the radiation was delivered to isocentric right-left and left-right fields via the extended distance technique. The kidneys and the liver were not shielded except in one patient with a left adrenal neuroblastoma. No patient required hemodialysis. The eGFR of four patients (44.4%) progressively decreased. The remaining patients did not demonstrate any eGFR deterioration. Only one patient developed hypertension. By evaluating the changes in eGFR, renal dysfunction among long-term survivors of TBI/HSCT could be detected. Our results suggested that the TBI schedule of 12 Gy in 6 fractions over three consecutive days affects renal function.


Assuntos
Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Nefropatias/diagnóstico , Nefropatias/etiologia , Neoplasias/complicações , Neoplasias/radioterapia , Sobreviventes , Irradiação Corporal Total/efeitos adversos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Estudos Longitudinais , Masculino , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA