Br J Nurs ; 29(21): 1277-1281, 2020 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-33242271

RESUMO

Electromagnetic (EM) guided enteral tube placement may reduce lung misplacement to almost zero in expert centres, but more than 60 undetected misplacements had occurred by 2016 resulting in major morbidity or death. AIM: Determine the accuracy of manufacturer guidance in trace interpretation against what is referred to as the 'GI flexure system'. METHODS: The authors prospectively observed the accuracy of the 'GI flexure system' of trace interpretation against manufacturer guidance in primary nasointestinal (NI) tube placements. FINDINGS: Contrary to manufacturer guidance, 33% of traces deviated >5 cm from the sagittal midline and 26.5% were oesophageal when entering the lower left quadrant, incorrectly indicating lung and gastric placement, respectively. Conversely, the GI flexure system identified ≥99.4% of GI traces when they reached the gastric body flexure; 100% at the superior duodenal flexure. All lung misplacements were identified by the absence of GI flexures. CONCLUSION: Current manufacturer guidance should be updated to the GI flexure system of interpretation.


Assuntos
Intubação Gastrointestinal , Fenômenos Eletromagnéticos , Humanos , Pulmão
2.
Br J Nurs ; 29(12): 662-668, 2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32579459

RESUMO

BACKGROUND: Blind (unguided) feeding tube placement results in 0.5% of patients suffering major complications mainly due to lung misplacement detected prior to feeding. Electromagnet-guided (Cortrak) tube placement could pre-empt such complications but undetected misplacements still occur due to incorrect trace interpretation. By identifying gastrointestinal (GI) flexures from the trace, 'the GI flexure system', it has been proposed that tube position can be interpreted. AIMS: To audit agreement between standards of interpreting tube position: the Cortrak 'GI flexure' system versus X-ray. METHODS: In 185 primary nasointestinal tube placements tube position determined by Cortrak trace interpretation (GI flexure) was retrospectively compared with radiological position in a blinded study. FINDINGS: Radiological and Cortrak interpretation agreed in 92.2-98.3% of placements at different GI flexures. Discrepancy mainly occurred because some radiological images were unclear or did not cover all anatomical points. CONCLUSION: The GI flexure method of Cortrak interpretation appears safe but would necessitate prospective radiological investigation to definitively test equivalence.


Assuntos
Intubação Gastrointestinal , Humanos , Estudos Prospectivos , Radiografia , Estudos Retrospectivos , Raios X
3.
Br J Nurs ; 28(18): 1170-1174, 2019 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-31597070

RESUMO

BACKGROUND: safe placement and securement of feeding tubes are essential to establishing early enteral nutrition. Nasogastric or nasojejunal feeding tubes are often inadvertently removed, and using a nasal bridle can reduce the number of tube replacements required. AIM: to review current nasal bridle practices on one intensive care unit. Over a 3-month period, nasal bridle use was recorded to measure unintentional tube loss and tube duration (the time a tube remained in situ). METHOD: an observational service evaluation. FINDINGS: 109 patients were recruited; 205 tubes were passed and 77 bridles were inserted, with 42% (n=46) of the bridles placed on day 1. Tubes secured with tape were more likely to be dislodged than tubes secured with a bridle, P=0.0001. Duration of tubes remaining in situ was significantly longer in patients who had a bridle fitted on day 1, P=0.0001 compared with tubes secured with tape. CONCLUSION: securing a tube with a nasal bridle from day 1 is independently associated with reduced tube loss, increased duration of tube use, and likelihood that the tube would reach redundancy when it was no longer required.


Assuntos
Nutrição Enteral/instrumentação , Falha de Equipamento/estatística & dados numéricos , Unidades de Terapia Intensiva , Intubação Gastrointestinal/instrumentação , Nutrição Enteral/métodos , Humanos , Intubação Gastrointestinal/métodos
4.
Child Care Health Dev ; 45(4): 606-612, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30995694

RESUMO

BACKGROUND: Many young people are involved in caring for parents, siblings, or other relatives who have an illness or disability. The aim of this study was to estimate the prevalence of caring by young people in England. METHOD: A national survey of 925 English young people was conducted using the 18-item survey version of the Multidimensional Assessment of Caring Activities Checklist for Young Carers. RESULTS: Around 7% of young people were identified as doing at least a high amount of caring activity and 3% a very high amount. Most frequently, caring by a young person is for a mother or a sibling, with a physical disability. Caring activity consisted mostly of domestic activities, household management, and emotional care. CONCLUSION: This study provides the most up to date and methodologically sophisticated survey data on the prevalence of young caring in England, with implications for policy and practice.


Assuntos
Cuidadores/estatística & dados numéricos , Filho de Pais com Deficiência/estatística & dados numéricos , Adolescente , Fatores Etários , Cuidadores/psicologia , Criança , Pessoas com Deficiência/estatística & dados numéricos , Empatia , Inglaterra , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Relações Pais-Filho , Prevalência , Fatores Sexuais
5.
Br J Nurs ; 27(18): 1036-1041, 2018 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-30281347

RESUMO

Over 50 % of tape-secured feeding tubes are inadvertently lost. The impact of nasal bridle securement on nasogastric (NG) and nasointestinal (NI) tube loss, outcome and duration of use was determined from 1 October 2014 (NG) and 1 January 2010 respectively to 31 December 2017. From this and published data, the potential impact of nasal bridles on major complications was determined. Use of nasal bridles was independently associated with: an 80% reduction in inadvertent NI tube loss (odds ratio (OR): 95% confidence interval (CI): 0.2: 0.12-0.33, p<0.0001); increased duration of tube use (2.2 days, 95% CI: 0.7-3.7, p= 0.004); and an almost threefold likelihood of tubes being used until no longer needed (OR: 2.8, 95%CI: 1.9-4.3, p<0.0001). In a single-room intensive care unit, inadvertent tube loss dropped from 53% to 9% and tube redundancy (tube no longer required) rose from 20% to 64%. UK-wide bridle securement, by reducing premature tube loss and the need for replacement by 40%, could be associated with 1422 fewer pneumonias or pneumothoraces and 768 fewer deaths.


Assuntos
Intubação Gastrointestinal/instrumentação , Adulto , Idoso , Estado Terminal , Feminino , Humanos , Intubação Gastrointestinal/efeitos adversos , Intubação Gastrointestinal/métodos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Retrospectivos
6.
Injury ; 49(10): 1922-1926, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30082111

RESUMO

BACKGROUND: Recent national (NICE) guidelines in England recommend that initial debridement and wound excision of open tibial fractures take place within 12 h of the time of injury, a change from the previous target of 24 h. This study aims to assess the effect of timing of the initial debridement and wound excision on major infective complications, the impact of the new guidance, and the feasibility of adhering to the 12 h target within the infrastructure currently existing in four major trauma centres in England. METHODS: A retrospective review was performed of Gustilo-Anderson grade 3B open tibial fractures presenting acutely to four Major Trauma Centres (MTCs) in England with co-located plastic surgery services over a ten-month period. The incidence of deep infective complications was compared between patients who underwent initial surgery according to the new NICE guidance and those who did not. Patients warranting emergency surgery for severely contaminated injury, concomitant life-threatening injury and neurovascular compromise were excluded. Multi-variable logistic regression analysis was performed to assess the effect of timing of surgical debridement on development of deep infective complications. RESULTS: 112 patients with 116 fractures were included. Six fractures (5.2%) developed deep infective complications. 38% (n = 44) underwent primary debridement within 12 h and 90% within 24 h. There was no significant difference in the incidence of major infective complications if debrided in less than or greater than 12 h (4.5% vs 5.6%, p = 1.00). Logistic regression found no significant relationship between timing of wound excision and development of deep infection. There was no significant decrease in mean time to debridement following introduction of new national guidance (13.6 vs 16.1 h) in these four MTCs. CONCLUSION: Overall, the rate of deep infection in high energy open tibial fractures managed within the four major trauma centes is low. Achieving surgical debridement within 12 h is challenging within the current infrastructure, and it is unclear whether adhering to this target will significantly affect the incidence of severe infective complications. Debridement within 24 h appears achievable. If a 12-h target is to be met, it is vital to ensure dedicated orthoplastic capacity is adequately resourced.


Assuntos
Desbridamento , Fraturas Expostas/cirurgia , Infecção da Ferida Cirúrgica/prevenção & controle , Fraturas da Tíbia/cirurgia , Centros de Traumatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desbridamento/métodos , Inglaterra , Fixação Interna de Fraturas , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Técnicas de Fechamento de Ferimentos , Adulto Jovem
7.
Br J Nurs ; 26(12): 656-663, 2017 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-28640722

RESUMO

Stroke patients with dysphagia often depend on nutrition, hydration and medication via nasogastric (NG) feeding tubes. Securing tubes using tape is associated with repeated tube loss. In this study, the authors determined cause and effect by auditing tube placement methods, delays incurred, duration and costs. Of 202 NG tube placements in 75 patients, 67 placements occurred in 17 patients over a full course of enteral nutrition (EN) and 40 of these placements were tracked. Tubes were secured by tape in 100%, mittens 31% and special observation 5.4%. However, over an EN course, inadvertent tube loss occurred in 82% of patients and was associated with age (p=0.049) and mitten use (p<0.001): 64% of tubes were lost due to patients and 9% slipped. Average 'tube life' was 2 days, less than 25% of the EN episode (p<0.001). While tube placement occurred within 2.55 hours of request, X-ray confirmation led to a delay in feed and drugs of 8-9 hours per tube placement and loss of 18.8% of feeding time per EN episode. Delays exceeded the 1-hour and 4-hour limits for antibiotics and other medicines in 20% and 80%, respectively. In the 17 tracked patients, it was estimated that 55% of the £5979 direct costs could be saved by nasal bridle use. In conclusion, most tubes studied were lost to inadvertent tube removal, leading to clinically significant delays to nutrition, hydration and drug treatments; this may impair recovery. Reducing tube loss is likely to reduce patient distress, treatment cost and enhance recovery.


Assuntos
Transtornos de Deglutição/enfermagem , Nutrição Enteral/instrumentação , Nutrição Enteral/métodos , Análise de Falha de Equipamento , Intubação Gastrointestinal/métodos , Acidente Vascular Cerebral/terapia , Fita Cirúrgica , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
8.
Clin Nutr ESPEN ; 14: 1-8, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-28531392

RESUMO

BACKGROUND & AIMS: Delayed gastric emptying (DGE) commonly limits the use of enteral nutrition (EN) and may increase ventilator-associated pneumonia. Nasointestinal feeding has not been tested against dual prokinetic treatment (Metoclopramide and Erythromycin) in DGE refractory to metoclopramide. This trial tests the feasibility of recruiting this 'treatment-failed' population and the proof of concept that nasointestinal (NI) feeding can increase the amount of feed tolerated (% goal) when compared to nasogastric (NG) feeding plus metoclopramide and erythromycin treatment. METHODS: Eligible patients were those who were mechanically ventilated and over 20 years old, with delayed gastric emptying (DGE), defined as a gastric residual volume ≥250 ml or vomiting, and who failed to respond to first-line prokinetic treatment of 3 doses of 10 mg IV metoclopramide over 24 h. When assent was obtained, patients were randomised to receive immediate nasointestinal tube placement and feeding or nasogastric feeding plus metoclopramide and erythromycin (prokinetic) treatment. RESULTS: Of 208 patients with DGE, 77 were eligible, 2 refused assent, 25 had contraindications to intervention, almost exclusively prokinetic treatment, and it was feasible to recruit 50. Compared to patients receiving prokinetics (n = 25) those randomised to nasointestinal feeding (n = 25) tolerated more of their feed goal over 5 days (87-95% vs 50-89%) and had a greater area under the curve (median [IQR] 432 [253-464]% vs 350 [213-381]%, p = 0.026) demonstrating proof of concept. However, nasointestinally fed patients also had a larger gastric loss (not feed) associated with the NI route but not with the fluid volume or energy delivered. CONCLUSIONS: This is first study showing that in DGE refractory to metoclopramide NI feeding can increase the feed goal tolerated when compared to dual prokinetic treatment. Future studies should investigate the effect on clinical outcomes. EU CLINICAL TRIALS REGISTER: EudraCT number: 2012-001374-29.


Assuntos
Estado Terminal/terapia , Nutrição Enteral/métodos , Esvaziamento Gástrico/efeitos dos fármacos , Intubação Gastrointestinal/métodos , Metoclopramida/uso terapêutico , Estado Nutricional , Falha de Tratamento , Adulto , Eritromicina/uso terapêutico , Feminino , Fármacos Gastrointestinais/uso terapêutico , Objetivos , Humanos , Intestino Delgado , Masculino , Metoclopramida/administração & dosagem , Pessoa de Meia-Idade , Resultado do Tratamento , Vômito/tratamento farmacológico
9.
Br J Nurs ; 23(12): 641-4, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25039627

RESUMO

Misplacing 17-23% of nasogastric (NG) tubes above the stomach ( Rollins et al, 2012 ; Rayner, 2013 ) represents a serious risk in terms of aspiration, further invasive (tube) procedures, irradiation from failed X-ray confirmation, delay to feed and medication. One causal factor is that in the National Patient Safety Agency (NPSA) guidance to place a tube, length is measured from nose to ear to xiphisternum (NEX) ( NSPA, 2011 ); NEX is incorrect because it only approximates the nose to gastro-oesophageal junction (GOJ) distance and is therefore too short. To overcome this and because the xiphisternum is more difficult to locate, local policy is to measure in the opposite direction; xiphisternum to ear to nose (XEN), then add 10 cm. The authors determined whether external body measurements can be used to estimate the NG tube length to safely reach the gastric body. This involved testing the statistical association of body length, age, sex and XEN in consecutive critically ill patients against internal anatomical landmarks determined from an electromagnetic (EM) trace of the tube path. XEN averaged 50 cm in 71 critically ill patients aged 53±20 years. Tube marking and the EM trace were used to determine mean insertion distances at pre-gastro-oesophageal junction (GOJ) (48 cm), where the tube first turns left towards the stomach and becomes shallow on the trace; gastric body (62 cm), where the tube reaches the left-most part of the stomach; and gastric antrum (73 cm) at the midline on the EM trace. Using body length, age, sex and XEN in a linear regression model, only 25% of variability was predicted, showing that external measurements cannot reliably predict the length of tube required to reach the stomach. A tube length of XEN (or NEX) is too short to guarantee gastric placement and is unsafe. XEN+10 cm or more complex measurements will reach the gastric body (mid-stomach) in most patients, but because of wide variation, external measurements often fail to predict a safe distance. Only the EM trace or possibly direct vision can show in real time whether the tip has safely reached the gastric body.


Assuntos
Intubação Gastrointestinal/enfermagem , Intubação Gastrointestinal/normas , Segurança do Paciente/normas , Pneumonia Aspirativa/prevenção & controle , Guias de Prática Clínica como Assunto/normas , Adulto , Idoso , Junção Esofagogástrica/diagnóstico por imagem , Feminino , Humanos , Intubação Gastrointestinal/métodos , Masculino , Pessoa de Meia-Idade , Radiografia , Processo Xifoide/diagnóstico por imagem
10.
Br J Nurs ; 23(7): 352, 354-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24732985

RESUMO

Recent evidence suggests official statistics greatly underestimate the occurrence of complications from misplaced nasogastric (NG) tubes, even when detected. Current methods of confirming tube position do not provide adequate protection from misplacement. In addition, some tubes are inadequately radio-opaque. We prospectively audited placement of Cortrak polyurethane tubes (PUTs) to determine: accuracy of the electromagnetic (EM) trace in confirming tube position, radio-opacity of PUTs compared with previously placed polyvinylchloride (PVC) Ryles tubes and whether 12 French PUTs can be used to aspirate gastric residual volumes (GRVs). A total of 127 PUTs were placed in 113 patients. EM traces accurately confirmed tube position compared with X-ray (100% agreement). A 'gastric' EM trace has been defined for future use by other operators. PUTs were adequately radio-opaque with good agreement between interpreters (>98%) whereas PVC Ryles tubes were insufficiently radio-opaque (57-73%), invisible in 23% of cases and with poor agreement between interpreters leaving risk of error. The alternative of using pH confirmation was not possible in 44%. In these cases subsequent X-ray incurred a 2-hour delay to feed and medicines. In addition, neither post-placement pH testing nor X-ray warn of lung placement and potential trauma, whereas the EM trace warned of lung placement prior to damage in 7% of placements. 12 French, single-port PUTs appear adequate to aspirate large GRVs. EM tracing may be considered a standalone method of confirming NG tube position. Corflo (Cortrak) PUTs are adequately radio-opaque. Use of PVC Ryles and other inadequately radio-opaque tubes should stop.


Assuntos
Campos Eletromagnéticos , Concentração de Íons de Hidrogênio , Intubação Gastrointestinal/métodos , Raios X , Humanos , Unidades de Terapia Intensiva , Intubação Gastrointestinal/instrumentação
11.
PLoS One ; 8(3): e58332, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23526977

RESUMO

In this work, the infrared (IR) spectra of living neural cells in suspension, native brain tissue, and native brain tumor tissue were investigated. Methods were developed to overcome the strong IR signal of liquid water so that the signal from the cellular biochemicals could be seen. Measurements could be performed during surgeries, within minutes after resection. Comparison between normal tissue, different cell lineages in suspension, and tumors allowed preliminary assignments of IR bands to be made. The most dramatic difference between tissues and cells was found to be in weaker IR absorbances usually assigned to the triple helix of collagens. Triple helix domains are common in larger structural proteins, and are typically found in the extracellular matrix (ECM) of tissues. An algorithm to correct offsets and calculate the band heights and positions of these bands was developed, so the variance between identical measurements could be assessed. The initial results indicate the triple helix signal is surprisingly consistent between different individuals, and is altered in tumor tissues. Taken together, these preliminary investigations indicate this triple helix signal may be a reliable biomarker for a tumor-like microenvironment. Thus, this signal has potential to aid in the intra-operational delineation of brain tumor borders.


Assuntos
Biomarcadores Tumorais/química , Biomarcadores Tumorais/metabolismo , Neoplasias Encefálicas/metabolismo , Proteínas de Neoplasias/química , Proteínas de Neoplasias/metabolismo , Proteínas do Tecido Nervoso/química , Proteínas do Tecido Nervoso/metabolismo , Espectrofotometria Infravermelho/métodos , Algoritmos , Animais , Encéfalo/metabolismo , Linhagem Celular , Linhagem Celular Tumoral , Colágeno/química , Colágeno/metabolismo , Matriz Extracelular/metabolismo , Glioblastoma/metabolismo , Humanos , Neoplasias Meníngeas/metabolismo , Meningioma/metabolismo , Camundongos , Camundongos Nus , Modelos Moleculares , Estrutura Secundária de Proteína , Ratos , Espectrofotometria Infravermelho/estatística & dados numéricos , Microambiente Tumoral
SELEÇÃO DE REFERÊNCIAS