Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Colloid Interface Sci ; 263(1): 80-3, 2003 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-12804888

RESUMO

Cobalt ferrite particles with diameters ranging from a few micrometer to about 15 nm were synthesized using a modified oxidation process. The fine control of the particle size was achieved by introducing various concentrations of Fe(3+) ions at the beginning of the reaction. Among the particle sizes obtained by using this method, particles with a grain size of about 36 nm showed a magnetization (M(s)) of 64 emu/g and a maximum coercivity (H(c)) of 2020 Oe at room temperature. The corresponding squareness ratio was found to be 0.53.

2.
J Electron Microsc (Tokyo) ; 50(4): 321-4, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11592677

RESUMO

High-resolution transmission electron microscopy and electron energy-loss spectroscopy of a multi-walled carbon nanotube (MWCNT) at elevated temperatures were studied. Although the observation was carried out at 200 kV, the crystal structures of the MWCNT were observed without introducing defects. In addition, contamination on the MWCNT, such as nanobubbles, was removed during the observation at 600 degrees C. In this paper, we report the observation conditions and experimental results. The experimental results obtained both at 600 degrees C and at room temperature were compared.

3.
J Synchrotron Radiat ; 8(Pt 2): 363-5, 2001 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11512781

RESUMO

In a conventional in-laboratory XAFS apparatus using conventional X-ray source, sealed tube or rotating anode, has been used. In which the X-ray source is fixed and the sample is moved (translated and rotated). Hence it has been difficult or required a complex method in order to put a heavy element, such as a cryogenic cooler, high temperature furnace and an in-situ reacting cell, at a sample position. Nowadays, there is a strong demand for obtaining dynamic information of a sample and in-situ observation becomes almost unavoidable. We have developed a compact X-ray tube and a new goniometer on which X-ray source is moved and monochromatic X-ray comes out of goniometer is fixed. Therefore it becomes easier to put a various cell at a sample position.

5.
Phys Rev B Condens Matter ; 36(17): 9410-9412, 1987 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-9942834
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...