Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 18(5)2018 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-29702598

RESUMO

Carbon fiber⁻epoxy composites have become prevalent in the aerospace industry where mechanical properties and light weight are at a premium. The significant non-destructive evaluation challenges of composites require new solutions, especially in detecting early-stage, or incipient, thermal damage. The initial stages of thermal damage are chemical rather than physical, and can cause significant reduction in mechanical properties well before physical damage becomes detectable in ultrasonic testing. Thermochromic fluorescent probe molecules have the potential to sense incipient thermal damage more accurately than traditional inspection methods. We have designed a molecule which transitions from a colorless, non-fluorescent state to a colorful, highly fluorescent state when exposed to temperature⁻time combinations that can cause damage in composites. Moreover, this molecule can be dispersed in a polymer film and attached to composite parts as a removable sensor. This work presents an evaluation of the sensor performance of this thermochromic film in comparison to ultrasonic C-scan as a method to detect incipient thermal damage in one of the most widely used carbon fiber⁻epoxy composite systems. Composite samples exposed to varying thermal exposures were used to evaluate the fluorescent thermal sensor films, and the results are compared to the results of ultrasonic imaging and short-beam shear tests for interlaminar shear strength.

2.
J Prosthet Dent ; 117(2): 303-309, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27666494

RESUMO

STATEMENT OF PROBLEM: Concern has been raised with regard to the low-temperature degradation (LTD) of translucent yttria-stabilized tetragonal zirconia polycrystalline (Y-TZP) for monolithic zirconia restorations. PURPOSE: The purpose of this in vitro study was to assess the LTD behavior of 4 commercially available translucent Y-TZP materials by accelerated aging specimens in steam at 134°C, 0.2 MPa. MATERIAL AND METHODS: Thin bars (22×3×0.2 mm) of Y-TZP, including Katana ML (Kuraray Noritake Dental Inc), Katana HT13 (Kuraray Noritake Dental Inc), Prettau (Zirkonzahn), and BruxZir (Glidewell Laboratories) (n=30 for each group), were machined from sintered blocks. Control specimens were assessed in the nonaged condition. Artificially ageing (n=5 per group at 5, 50, 100, 150, and 200 hours) was conducted in steam at 134°C at 0.2 MPa. The specimens were characterized, tested in 4-point flexure, and the fracture surfaces were analyzed. The monoclinic-to-tetragonal (m/t) peak intensity ratio measured by x-ray diffraction was used to calculate the monoclinic phase fraction and monitor LTD. Linear regression with heteroscedasticity-consistent robust standard errors was used to test for the effect of LTD (aging time) on (σf) and m/t. The Spearman rank correlation coefficient was used to assess the relationship between σf and monoclinic phase fraction (α=.05). RESULTS: Artificial aging resulted in LTD as shown by an increase in the monoclinic phase fraction for all specimens. After aging for 200 hours, the mean ±SD monoclinic phase fraction increased from 2.90 ±0.34% to 76.1 ±0.64% for Prettau, 2.69 ±0.18% to 76.0 ±0.26% for BruxZir, 4.6 ±0.19% to 35.8 ±0.80% for Katana HT13, and 3.57 ±0.35% to 33.2 ±1.1% for Katana ML (all P<.001). Flexural strength changed from a mean ±SD of 1612 ±197 MPa to all fractured during aging for Prettau (P<.001); 1248 ±73.5 MPa to all fractured during aging for BruxZir (P<.001); 1052 ±84.2 to 1099 ±70 MPa ±130 for Katana HT13 (P=.45); and from 875 ±130 to 909 ±70 MPa (P=.82) for Katana ML. The mean flexural strength values of Prettau and BruxZir decreased with an increase in the monoclinic phase with Spearman rank correlation coefficients of -0.80 (P=.001) for Prettau and -0.63 (P=.022) for BruxZir. No significant changes in flexural strength were measured for Katana ML or Katana HT13 (P>.05). CONCLUSIONS: The LTD of Y-TZP resulted in a significant decrease in flexural strength of Prettau and BruxZir, whereas Katana ML and Katana HT13 exhibited less LTD and no significant decrease in flexural strength.


Assuntos
Cerâmica/química , Restauração Dentária Permanente/métodos , Ítrio/química , Zircônio/química , Cerâmica/uso terapêutico , Análise do Estresse Dentário , Resistência à Tração , Fatores de Tempo , Ítrio/uso terapêutico , Zircônio/uso terapêutico
3.
Adv Mater ; 28(31): 6592-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27184010

RESUMO

A new class of rationally designed mechanophores is developed for highly sensitive built-in strain sensors in polymer composites. These mechanophores are designed to regenerate the π-conjugation pathway between the electron donor and electron acceptor by force-induced cleavage of the covalent bond to form a fluorescent dipolar dye.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...