Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lab Chip ; 20(18): 3302-3309, 2020 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-32743622

RESUMO

To detect the presence of antibodies in blood against SARS-CoV-2 in a highly sensitive and specific manner, here we describe a robust, inexpensive ($200), 3D-printable portable imaging platform (TinyArray imager) that can be deployed immediately in areas with minimal infrastructure to read coronavirus antigen microarrays (CoVAMs) that contain a panel of antigens from SARS-CoV-2, SARS-1, MERS, and other respiratory viruses. Application includes basic laboratories and makeshift field clinics where a few drops of blood from a finger prick could be rapidly tested in parallel for the presence of antibodies to SARS-CoV-2 with a test turnaround time of only 2-4 h. To evaluate our imaging device, we probed and imaged coronavirus microarrays with COVID-19-positive and negative sera and achieved a performance on par with a commercial microarray reader 100× more expensive than our imaging device. This work will enable large scale serosurveillance, which can play an important role in the months and years to come to implement efficient containment and mitigation measures, as well as help develop therapeutics and vaccines to treat and prevent the spread of COVID-19.


Assuntos
Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Análise em Microsséries/métodos , Pneumonia Viral/diagnóstico , COVID-19 , Teste para COVID-19 , Infecções por Coronavirus/imunologia , Humanos , Microscopia , Pandemias , Pneumonia Viral/imunologia , Impressão Tridimensional , Vigilância em Saúde Pública , Pontos Quânticos
2.
Sci Rep ; 10(1): 12458, 2020 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-32719382

RESUMO

Rapidly isolating rare targets from larger, clinically relevant fluid volumes remains an unresolved problem in biomedicine and diagnosis. Here, we describe how 3D particle sorting can enrich targets at ultralow concentrations over 100-fold within minutes not possible with conventional approaches. Current clinical devices based on biochemical extraction and microfluidic solutions typically require high concentrations and/or can only process sub-milliliter volumes in time. In a proof-of-concept application, we isolated bacteria from whole blood as demanded for rapid sepsis diagnosis where minimal numbers of bacteria need to be found in a 1-10 mL blood sample. After sample encapsulation in droplets and target enrichment with the 3D particle sorter within a few minutes, downstream analyses were able to identify bacteria and test for antibiotic susceptibility, information which is critical for successful treatment of bloodstream infections.


Assuntos
Bactérias/isolamento & purificação , Sangue/microbiologia , Microfluídica/métodos , Sepse/sangue , Sepse/microbiologia , Humanos , Microfluídica/instrumentação , Sepse/diagnóstico
3.
bioRxiv ; 2020 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-32511369

RESUMO

To detect the presence of antibodies in blood against SARS-CoV-2 in a highly sensitive and specific manner, here we describe a robust, inexpensive ($200), 3D-printable portable imaging platform (TinyArray imager) that can be deployed immediately in areas with minimal infrastructure to read coronavirus antigen microarrays (CoVAMs) that contain a panel of antigens from SARS-CoV-2, SARS-1, MERS, and other respiratory viruses. Application includes basic laboratories and makeshift field clinics where a few drops of blood from a finger prick could be rapidly tested in parallel for the presence of antibodies to SARS-CoV-2 with a test turnaround time of only 2-4 h. To evaluate our imaging device, we probed and imaged coronavirus microarrays with COVID-19-positive and negative sera and achieved a performance on par with a commercial microarray reader 100x more expensive than our imaging device. This work will enable large scale serosurveillance, which can play an important role in the months and years to come to implement efficient containment and mitigation measures, as well as help develop therapeutics and vaccines to treat and prevent the spread of COVID-19.

4.
J Med Microbiol ; 69(1): 52-62, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31846419

RESUMO

Introduction. The alarming rise in urinary tract infection (UTI) antimicrobial resistance has resulted from a combination of high prevalence, low specificity and the lack of a rapid, point-of-care (POC) antibiotic susceptibility test (AST), which has led to the overuse/inappropriate use of antibiotics.Aim. This study aimed to evaluate the performance of a rapid POC phenotypic AST device in reporting susceptibility information within 2 h.Methodology. Instrument calibration was performed with model bacteria and fluorescent microbeads to determine the dynamic range and limit of detection for quantifying concentrations of bacteria and demonstrate the ability to rapidly differentiate susceptible and resistant model bacteria. We then evaluated 30 presumptive UTI-positive patient urine samples in a clinical pilot study using a panel of 5 common UTI antibiotics plus a growth control and compared our results to the hospital standard of care AST.Results. Our device was able to robustly detect and quantify bacteria concentrations from 50 to 105 colony-forming units (c.f.u.) ml-1. The high sensitivity of this measurement technique enabled the device to differentiate between susceptible and resistant model bacteria with 100 % specificity over a 2 h growth period. In the clinical pilot study, an overall categorical agreement (CA) of 90.7 % was observed (sensitivity=91.4 %, specificity=88.9 %, n=97) with performance for individual drugs ranging from 85 % CA (ceftazidime) to 100 % (nitrofurantoin).Conclusions. By reducing the typical timeframe for susceptibility testing from 2-3 days to 2 h, our POC phenotypic AST can provide critical information to clinicians prior to the administration of antibiotic therapy.


Assuntos
Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Testes de Sensibilidade Microbiana/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Infecções Urinárias/microbiologia , Bactérias/isolamento & purificação , Humanos , Projetos Piloto , Sensibilidade e Especificidade , Fatores de Tempo , Urina/microbiologia
5.
Lab Chip ; 20(3): 477-489, 2020 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-31872202

RESUMO

Sepsis due to antimicrobial resistant pathogens is a major health problem worldwide. The inability to rapidly detect and thus treat bacteria with appropriate agents in the early stages of infections leads to excess morbidity, mortality, and healthcare costs. Here we report a rapid diagnostic platform that integrates a novel one-step blood droplet digital PCR assay and a high throughput 3D particle counter system with potential to perform bacterial identification and antibiotic susceptibility profiling directly from whole blood specimens, without requiring culture and sample processing steps. Using CTX-M-9 family ESBLs as a model system, we demonstrated that our technology can simultaneously achieve unprecedented high sensitivity (10 CFU per ml) and rapid sample-to-answer assay time (one hour). In head-to-head studies, by contrast, real time PCR and BioRad ddPCR only exhibited a limit of detection of 1000 CFU per ml and 50-100 CFU per ml, respectively. In a blinded test inoculating clinical isolates into whole blood, we demonstrated 100% sensitivity and specificity in identifying pathogens carrying a particular resistance gene. We further demonstrated that our technology can be broadly applicable for targeted detection of a wide range of antibiotic resistant genes found in both Gram-positive (vanA, nuc, and mecA) and Gram-negative bacteria, including ESBLs (blaCTX-M-1 and blaCTX-M-2 families) and CREs (blaOXA-48 and blaKPC), as well as bacterial speciation (E. coli and Klebsiella spp.) and pan-bacterial detection, without requiring blood culture or sample processing. Our rapid diagnostic technology holds great potential in directing early, appropriate therapy and improved antibiotic stewardship in combating bloodstream infections and antibiotic resistance.


Assuntos
Antibacterianos/farmacologia , Enterobacteriaceae/efeitos dos fármacos , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Reação em Cadeia da Polimerase , Enterococos Resistentes à Vancomicina/efeitos dos fármacos , Enterobacteriaceae/isolamento & purificação , Humanos , Dispositivos Lab-On-A-Chip , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Técnicas Analíticas Microfluídicas/instrumentação , Tamanho da Partícula , Propriedades de Superfície , Enterococos Resistentes à Vancomicina/isolamento & purificação
6.
Elife ; 72018 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-30152756

RESUMO

Most bacteria use an indirect pathway to generate aminoacylated glutamine and/or asparagine tRNAs. Clinical isolates of Mycobacterium tuberculosis with increased rates of error in gene translation (mistranslation) involving the indirect tRNA-aminoacylation pathway have increased tolerance to the first-line antibiotic rifampicin. Here, we identify that the aminoglycoside kasugamycin can specifically decrease mistranslation due to the indirect tRNA pathway. Kasugamycin but not the aminoglycoside streptomycin, can limit emergence of rifampicin resistance in vitro and increases mycobacterial susceptibility to rifampicin both in vitro and in a murine model of infection. Moreover, despite parenteral administration of kasugamycin being unable to achieve the in vitro minimum inhibitory concentration, kasugamycin alone was able to significantly restrict growth of Mycobacterium tuberculosis in mice. These data suggest that pharmacologically reducing mistranslation may be a novel mechanism for targeting bacterial adaptation.


Assuntos
Aminoglicosídeos/farmacologia , Farmacorresistência Bacteriana/efeitos dos fármacos , Mycobacterium tuberculosis/efeitos dos fármacos , Biossíntese de Proteínas/efeitos dos fármacos , Rifampina/farmacologia , Aminoacilação , Aminoglicosídeos/administração & dosagem , Aminoglicosídeos/farmacocinética , Aminoglicosídeos/uso terapêutico , Animais , Sinergismo Farmacológico , Edeína/farmacologia , Injeções Intraperitoneais , Camundongos , Testes de Sensibilidade Microbiana , Especificidade de Órgãos , RNA de Transferência/metabolismo , Rifampina/uso terapêutico , Estreptomicina/administração & dosagem , Estreptomicina/farmacocinética , Estreptomicina/farmacologia , Estreptomicina/uso terapêutico , Tuberculose/tratamento farmacológico , Tuberculose/microbiologia , Tuberculose/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...