Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 12(5)2022 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-35624659

RESUMO

Wearable biosensors for continuous health monitoring, particularly those used for glucose detection, have a limited operational lifetime due to biodegradation and fouling. As a result, patients must change sensors frequently, increasing cost and patient discomfort. Arrays of multiple sensors, where the individual devices can be activated on demand, increase overall operational longevity, thereby reducing cost and improving patient outcomes. This work demonstrates the feasibility of this approach via decomposition of combustible nitrocellulose membranes that protect the individual sensors from exposure to bioanalytes using a current pulse. Metal contacts, connected by graphene-loaded PEDOT:PSS polymer on the surface of the membrane, deliver the required energy to decompose the membrane. Nitrocellulose membranes with a thickness of less than 1 µm consistently transfer on to polydimethylsiloxane (PDMS) wells. An electrical energy as low as 68 mJ has been shown to suffice for membrane decomposition.


Assuntos
Técnicas Biossensoriais , Grafite , Colódio , Humanos , Polímeros
2.
Adv Sci (Weinh) ; 9(8): e2104644, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35043603

RESUMO

Tripartite coupling between phonons, magnons, and photons in a periodic array of elliptical magnetostrictive nanomagnets delineated on a piezoelectric substrate to form a 2D two-phase multiferroic crystal is investigated. Surface acoustic waves (SAW) (phonons) of 5-35 GHz frequency launched into the substrate cause the magnetizations of the nanomagnets to precess at the frequency of the wave, giving rise to confined spin-wave modes (magnons) within the nanomagnets. The spin waves, in turn, radiate electromagnetic waves (photons) into the surrounding space at the SAW frequency. Here, the phonons couple into magnons, which then couple into photons. This tripartite phonon-magnon-photon coupling is thus exploited to implement an extreme sub-wavelength electromagnetic antenna whose measured radiation efficiency and antenna gain exceed the approximate theoretical limits for traditional antennas of the same dimensions by more than two orders of magnitude at some frequencies. Micro-magnetic simulations are in excellent agreement with experimental observations and provide insight into the spin-wave modes that couple into radiating electromagnetic modes to implement the antenna.

3.
Drug Chem Toxicol ; 45(2): 767-774, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32529856

RESUMO

The Portable In Vitro Exposure Cassette (PIVEC) was developed for on-site air quality testing using lung cells. Here, we describe the incorporation of a sensor within the PIVEC for real time monitoring of cellular oxidative stress during exposure to contaminated air. An electrochemical, enzymatic biosensor based on cytochrome c (cyt c) was selected to measure reactive oxygen species (ROS), including hydrogen peroxide and super oxides, due to the stability of signal over time. Human A549 lung cells were grown at the air-liquid interface and exposed within the PIVEC to dry 40 nm copper nanoparticle aerosols for 10 minutes. The generation of ROS compounds was measured during exposure and post-exposure for one hour using the biosensor and compared to intracellular ROS determined using the 2',7'-dichlorodihydrofluoroscein diacetate (DCFH-DA) assay. A similar increase in oxidative stress upon aerosol exposure was measured using both the cyt c biosensor and DCFH-DA assay. The incorporation of a biosensor within the PIVEC is a unique, first-of-its-kind system designed to monitor the real-time effect of aerosols.


Assuntos
Peróxido de Hidrogênio , Estresse Oxidativo , Aerossóis/química , Aerossóis/farmacologia , Humanos , Peróxido de Hidrogênio/farmacologia , Oxirredução , Estudo de Prova de Conceito , Espécies Reativas de Oxigênio
4.
Toxicol Res (Camb) ; 7(5): 754-759, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30210779

RESUMO

This study evaluated the cytocompatibility of single- and poly-crystalline ZnO thin films using extract and direct contact methods. Exposure to poly-crystalline ZnO extract resulted in reduced cell viability, on average 82%/70% as measured by MTS/LDH assays, respectively. Direct exposure to both single- and poly-crystalline ZnO thin films resulted in reduced cell viability, which was attributed to anoikis due to inhibition of cell adhesion to the substrate by zinc. Intracellular zinc imaging suggests that single crystalline ZnO thin films do not result in a significant change in intracellular zinc concentrations. Overall, the results suggest that single-crystalline ZnO thin films have better short-term (24 h) cytocompatibility and support their potential to serve as a biocompatible sensor material.

5.
Proc SPIE Int Soc Opt Eng ; 85842013 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-24244830

RESUMO

BACKGROUND: There are numerous clinical applications for non-invasive monitoring of deep tissue temperature. We present the design and experimental performance of a miniature radiometric thermometry system for measuring volume average temperature of tissue regions located up to 5cm deep in the body. METHODS: We constructed a miniature sensor consisting of EMI-shielded log spiral microstrip antenna with high gain on-axis and integrated high-sensitivity 1.35GHz total power radiometer with 500 MHz bandwidth. We tested performance of the radiometry system in both simulated and experimental multilayer phantom models of several intended clinical measurement sites: i) brown adipose tissue (BAT) depots within 2cm of the skin surface, ii) 3-5cm deep kidney, and iii) human brain underlying intact scalp and skull. The physical models included layers of circulating tissue-mimicking liquids controlled at different temperatures to characterize our ability to quantify small changes in target temperature at depth under normothermic surface tissues. RESULTS: We report SAR patterns that characterize the sense region of a 2.6cm diameter receive antenna, and radiometric power measurements as a function of deep tissue temperature that quantify radiometer sensitivity. The data demonstrate: i) our ability to accurately track temperature rise in realistic tissue targets such as urine refluxed from prewarmed bladder into kidney, and 10°C drop in brain temperature underlying normothermic scalp and skull, and ii) long term accuracy and stability of ∓0.4°C over 4.5 hours as needed for monitoring core body temperature over extended surgery or monitoring effects of brown fat metabolism over an extended sleep/wake cycle. CONCLUSIONS: A non-invasive sensor consisting of 2.6cm diameter receive antenna and integral 1.35GHz total power radiometer has demonstrated sufficient sensitivity to track clinically significant changes in temperature of deep tissue targets underlying normothermic surface tissues for clinical applications like the detection of vesicoureteral reflux, and long term monitoring of brown fat metabolism or brain core temperature during extended surgery.

6.
Proc SPIE Int Soc Opt Eng ; 85842013 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-24244831

RESUMO

BACKGROUND: Brown adipose tissue (BAT) plays an important role in whole body metabolism and could potentially mediate weight gain and insulin sensitivity. Although some imaging techniques allow BAT detection, there are currently no viable methods for continuous acquisition of BAT energy expenditure. We present a non-invasive technique for long term monitoring of BAT metabolism using microwave radiometry. METHODS: A multilayer 3D computational model was created in HFSS™ with 1.5 mm skin, 3-10 mm subcutaneous fat, 200 mm muscle and a BAT region (2-6 cm3) located between fat and muscle. Based on this model, a log-spiral antenna was designed and optimized to maximize reception of thermal emissions from the target (BAT). The power absorption patterns calculated in HFSS™ were combined with simulated thermal distributions computed in COMSOL® to predict radiometric signal measured from an ultra-low-noise microwave radiometer. The power received by the antenna was characterized as a function of different levels of BAT metabolism under cold and noradrenergic stimulation. RESULTS: The optimized frequency band was 1.5-2.2 GHz, with averaged antenna efficiency of 19%. The simulated power received by the radiometric antenna increased 2-9 mdBm (noradrenergic stimulus) and 4-15 mdBm (cold stimulus) corresponding to increased 15-fold BAT metabolism. CONCLUSIONS: Results demonstrated the ability to detect thermal radiation from small volumes (2-6 cm3) of BAT located up to 12 mm deep and to monitor small changes (0.5 °C) in BAT metabolism. As such, the developed miniature radiometric antenna sensor appears suitable for non-invasive long term monitoring of BAT metabolism.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...