Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 14(1): 6795, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37880209

RESUMO

O-acetylation is a common modification of sialic acids that has been implicated in a multitude of biological and disease processes. A lack of analytical methods that can determine exact structures of sialic acid variants is a hurdle to determine roles of distinct O-acetylated sialosides. Here, we describe a drift tube ion mobility-mass spectrometry approach that can elucidate exact O-acetylation patterns as well as glycosidic linkage types of sialosides isolated from complex biological samples. It is based on the use of a library of synthetic O-acetylated sialosides to establish intrinsic collision cross section (CCS) values of diagnostic fragment ions. The CCS values were used to characterize O-acetylated sialosides from mucins and N-linked glycans from biologicals as well as equine tracheal and nasal tissues. It uncovered contrasting sialic acid linkage types of acetylated and non-acetylated sialic acids and provided a rationale for sialic acid binding preferences of equine H7 influenza A viruses.


Assuntos
Glicosídeos Cardíacos , Ácido N-Acetilneuramínico , Animais , Cavalos , Ácido N-Acetilneuramínico/metabolismo , Glicosídeos , Acetilação , Ácidos Siálicos/metabolismo , Espectrometria de Massas
2.
Artigo em Inglês | MEDLINE | ID: mdl-33540147

RESUMO

Erlotinib is a first-generation epithelial growth factor receptor inhibitor used in the treatment of non-small cellular lung cancers. Our previously published method on a Thermo TSQ Quantum Ultra triple quadrupole mass spectrometer for the quantitation of erlotinib, OSI-420, and OSI-413 and some other kinase inhibitors was transferred to a more sensitive Sciex QTRAP5500 system. Both methods showed comparable performance in the previous range (5-5000 and 1-1000 ng/mL for erlotinib and OSI-420) with comparable accuracies and precisions (98.9-106.2 vs 98.7.0-104.0, and 3.7-13.4 vs 4.6-13.2), and a high level of agreement between the methods (R2 = 0.9984 and 0.9951) for the quality control samples. The new system however was also capable of quantifying lower concentrations of both erlotinib and OSI-420 (0.5 and 0.1 ng/mL) with sufficient accuracy and precision. Along with the increased sensitivity we included the semi-quantitative determination of additional erlotinib metabolites M2, M3, M5, M6, M7, M8, M9, M10, M11, M12, M16 (hydroxy-erlotinib), M17, M18, M19, M20, M21 in a 0.1-1000 ng/mL range to the method. With a simple crash, dilute, and shoot sample preparation with acetonitrile and a 4.5 min analytical run time the method outperformed most other published methods in speed and simplicity and was suitable for TDM. Further, enhancement of the understanding of the pharmacokinetics of erlotinib and its metabolites was demonstrated.


Assuntos
Cromatografia Líquida/métodos , Cloridrato de Erlotinib , Quinazolinas , Espectrometria de Massas em Tandem/métodos , Cloridrato de Erlotinib/análogos & derivados , Cloridrato de Erlotinib/análise , Cloridrato de Erlotinib/química , Isomerismo , Modelos Lineares , Quinazolinas/análise , Quinazolinas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Mol Pharm ; 17(4): 1276-1292, 2020 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-32142290

RESUMO

meta-Tetra(hydroxyphenyl)chlorin (mTHPC) is one of the most potent second-generation photosensitizers, clinically used for photodynamic therapy (PDT) of head and neck squamous cell carcinomas. However, improvements are still required concerning its present formulation (i.e., Foscan, a solution of mTHPC in ethanol/propylene glycol (40:60 w/w)), as mTHPC has the tendency to aggregate in aqueous media, e.g., biological fluids, and it has limited tumor specificity. In the present study, polymeric micelles with three different diameters (17, 24, and 45 nm) based on benzyl-poly(ε-caprolactone)-b-poly(ethylene glycol) (PCLn-PEG; n = 9, 15, or 23) were prepared with mTHPC loadings ranging from 0.5 to 10 wt % using a film-hydration method as advanced nanoformulations for this photosensitizer. To favor the uptake of the micelles by cancer cells that overexpress the epidermal growth factor receptor (EGFR), the micelles were decorated with an EGFR-targeted nanobody (named EGa1) through maleimide-thiol chemistry. The enhanced binding of the EGFR-targeted micelles at 4 °C to EGFR-overexpressing A431 cells, compared to low-EGFR-expressing HeLa cells, confirmed the specificity of the micelles. In addition, an enhanced uptake of mTHPC-loaded micelles by A431 cells was observed when these were decorated with the EGa1 nanobody, compared to nontargeted micelles. Both binding and uptake of targeted micelles were blocked by an excess of free EGa1 nanobody, demonstrating that these processes occur through EGFR. In line with this, mTHPC loaded in EGa1-conjugated PCL23-PEG (EGa1-P23) micelles demonstrated 4 times higher photocytotoxicity on A431 cells, compared to micelles lacking the nanobody. Importantly, EGa1-P23 micelles also showed selective PDT against A431 cells compared to the low-EGFR-expressing HeLa cells. Finally, an in vivo pharmacokinetic study shows that after intravenous injection, mTHPC incorporated in the P23 micelles displayed prolonged blood circulation kinetics, compared to free mTHPC, independently of the presence of EGa1. Thus, these results make these micelles a promising nanomedicine formulation for selective therapy.


Assuntos
Mesoporfirinas/farmacologia , Polímeros/química , Anticorpos de Domínio Único/química , Anticorpos de Domínio Único/farmacologia , Animais , Linhagem Celular Tumoral , Sistemas de Liberação de Medicamentos/métodos , Receptores ErbB/metabolismo , Etilenoglicóis/química , Feminino , Células HeLa , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Micelas , Nanomedicina/métodos , Nanopartículas/química , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/química , Fármacos Fotossensibilizantes/farmacologia , Poliésteres/química , Polietilenoglicóis/química
4.
J Control Release ; 293: 113-125, 2019 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-30472374

RESUMO

The aim of the present study was to develop folic acid (FA) conjugates which can deliver the kinase inhibitor dactolisib to the kidneys via folate receptor-mediated uptake in tubular epithelial cells. Dactolisib is a dual inhibitor of phosphatidylinositol 3-kinase (PI3K) and mammalian target of rapamycin (mTOR) and is considered an attractive agent for treatment of polycystic kidney disease. The ethylenediamine platinum(II) linker, herein called Lx, was employed to couple dactolisib via coordination chemistry to thiol-containing FA-spacer adducts to yield FA-Lx-dactolisib conjugates. The dye lissamine was coupled via similar linker chemistry to folate to yield fluorescent FA-Lx-lissamine conjugates. Three different spacers (PEG5-Cys, PEG27-Cys or an Asp-Arg-Asp-Asp-Cys peptide spacer) were used to compare the influence of hydrophilicity and charged groups in the spacer on interaction with target cells and in vivo organ distribution of the final conjugates. The purity and identity of the final products were confirmed by UPLC and LC-MS analysis, respectively. FA-Lx-dactolisib conjugates were stable in serum and culture medium, while dactolisib was released from the conjugates in the presence of glutathione. All three type of conjugates were internalized efficiently by HK-2 cells and uptake could be blocked by an excess of folic acid in the medium, demonstrating FR mediated uptake. FA-Lx-dactolisib conjugates showed nanomolar inhibition of the PI3K pathway (Akt phosphorylation) and mTOR pathway (S6 phosphorylation) in cultured kidney epithelial cells (HK-2 cells). After intraperitoneal administration, all three types conjugates accumulated extensively in kidneys of iKsp-Pkd1del mice with polycystic kidney disease. In conclusion, folate conjugates were successfully prepared by platinum(II) coordination chemistry and accumulated in a target-specific manner in kidney cells and polycystic kidneys. The folate conjugate of dactolisib thus may have potential for targeted therapy of polycystic kidney disease.


Assuntos
Antineoplásicos/administração & dosagem , Ácido Fólico/administração & dosagem , Imidazóis/administração & dosagem , Inibidores de Fosfoinositídeo-3 Quinase/administração & dosagem , Doenças Renais Policísticas/tratamento farmacológico , Quinolinas/administração & dosagem , Linhagem Celular , Liberação Controlada de Fármacos , Ácido Fólico/química , Humanos , Imidazóis/química , Túbulos Renais/citologia , Fosfatidilinositol 3-Quinases/metabolismo , Inibidores de Fosfoinositídeo-3 Quinase/química , Doenças Renais Policísticas/metabolismo , Quinolinas/química , Serina-Treonina Quinases TOR/antagonistas & inibidores , Serina-Treonina Quinases TOR/metabolismo
5.
J Am Chem Soc ; 139(2): 1011-1018, 2017 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-28002670

RESUMO

Progress in glycoscience is hampered by a lack of well-defined complex oligosaccharide standards that are needed to fabricate the next generation of microarrays, to develop analytical protocols to determine exact structures of isolated glycans, and to elucidate pathways of glycan biosynthesis. We describe here a chemoenzymatic methodology that makes it possible, for the first time, to prepare any bi-, tri-, and tetra-antennary asymmetric N-glycan from a single precursor. It is based on the chemical synthesis of a tetra-antennary glycan that has N-acetylglucosamine (GlcNAc), N-acetyllactosamine (LacNAc), and unnatural Galα(1,4)-GlcNAc and Manß(1,4)-GlcNAc appendages. Mammalian glycosyltransferases recognize only the terminal LacNAc moiety as a substrate, and thus this structure can be uniquely extended. Next, the ß-GlcNAc terminating antenna can be converted into LacNAc by galactosylation and can then be enzymatically modified into a complex structure. The unnatural α-Gal and ß-Man terminating antennae can sequentially be decaged by an appropriate glycosidase to liberate a terminal ß-GlcNAc moiety, which can be converted into LacNAc and then elaborated by a panel of glycosyltransferases. Asymmetric bi- and triantennary glycans could be obtained by removal of a terminal ß-GlcNAc moiety by treatment with ß-N-acetylglucosaminidase and selective extension of the other arms. The power of the methodology is demonstrated by the preparation of an asymmetric tetra-antennary N-glycan found in human breast carcinoma tissue, which represents the most complex N-glycan ever synthesized. Multistage mass spectrometry of the two isomeric triantennary glycans uncovered unique fragment ions that will facilitate identification of exact structures of glycans in biological samples.


Assuntos
Glicosídeo Hidrolases/síntese química , Polissacarídeos/química , Animais , Glicosídeo Hidrolases/química , Humanos
6.
Bioelectrochemistry ; 112: 153-7, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26936113

RESUMO

The impregnation of leafy vegetables with cryoprotectants using a combination of vacuum impregnation (VI) and pulsed electric fields (PEF) has been proposed by our research group as a method of improving their freezing tolerance and consequently their general quality after thawing. In this study, we have investigated the metabolic consequences of the combination of these unit operations on spinach. The vacuum impregnated spinach leaves showed a drastic decrease in the porosity of the extracellular space. However, at maximum weight gain, randomly located air pockets remained, which may account for oxygen-consuming pathways in the cells being active after VI. The metabolic activity of the impregnated leaves showed a drastic increase that was further enhanced by the application of PEF to the impregnated tissue. Impregnating the leaves with trehalose by VI led to a significant accumulation of trehalose-6-phosphate (T6P), however, this was not further enhanced by PEF. It is suggested that the accumulation of T6P in the leaves may increase metabolic activity, and increase tissue resistance to abiotic stress.


Assuntos
Eletricidade , Folhas de Planta/efeitos dos fármacos , Folhas de Planta/metabolismo , Spinacia oleracea/efeitos dos fármacos , Spinacia oleracea/metabolismo , Trealose/farmacologia , Criopreservação , Porosidade , Fosfatos Açúcares/metabolismo , Trealose/análogos & derivados , Trealose/metabolismo , Vácuo
7.
Artigo em Inglês | MEDLINE | ID: mdl-26038236

RESUMO

Cytochrome P450 1A2 (CYP1A2) plays an important role in drug metabolism. Caffeine (CAF) is converted into paraxanthine (PX) by this enzyme and is used as a xenobiotic substrate to determine the CYP1A2 phenotype in humans. A method for the quantification of CAF and PX in saliva was developed using liquid-liquid extraction with ethyl acetate and analysis with ultra-high-performance liquid chromatography. Peaks from CAF, PX and internal standard were resolved within 6min. The method was validated from 0.05 to 5µgmL(-1) CAF and 0.025-2.5µgmL(-1) PX. Inter- and intra-day accuracies ranged from 91.2 to 107.2% with precisions <13.5%. The limits of detection were 0.16 and 0.63 ngmL(-1) for PX and CAF, respectively. PX/CAF concentration ratios from volunteers were 0.26-1.09 with mean ratios of 0.78±0.26 and 0.38±0.10 for regular and light/non-coffee drinkers, respectively.


Assuntos
Cafeína/análise , Cromatografia Líquida de Alta Pressão/métodos , Citocromo P-450 CYP1A2/classificação , Saliva/química , Teofilina/análise , Cafeína/metabolismo , Citocromo P-450 CYP1A2/metabolismo , Humanos , Modelos Lineares , Fenótipo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Teofilina/metabolismo
8.
Electrophoresis ; 34(18): 2615-22, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23857580

RESUMO

A new MEKC-ESI-MS method for the analysis of amino acids (AAs) in human urine was developed employing ammonium perfluorooctanoate (APFO) as volatile surfactant. The influence of APFO on the MS signal of AAs was evaluated by infusion experiments, which showed that APFO hardly affects analyte responses and presents significantly less ion suppression than equal concentrations of ammonium acetate. In order to obtain efficient separation of AAs, MEKC parameters such as the pH and APFO concentration of the BGE, were optimized. Optimum AA resolution, including baseline separation of leucine and isoleucine, was obtained using 150 mM APFO (pH 9.0) as BGE, representing a considerable selectivity improvement over CE using 50 mM ammonium acetate (pH 9.0). Optimization of CE-MS parameters, such as sheath liquid composition and flow rate, and ESI and MS settings, led to LODs ranging from 9 to 26 ng/mL for the 20 tested AAs, which is highly favorable for an MEKC-MS method. Good linearity (r(2) > 0.99) and repeatability were obtained for all AAs tested with RSD values of 3.0-6.7% for peak area and <1.5% for migration time. The applicability of the MEKC-MS method was demonstrated by the quantitative determination of AAs in urine employing only a 1:1 dilution with BGE as sample pretreatment. All AAs could selectively be detected and quantified obtaining relevant concentration values for normal human urine.


Assuntos
Aminoácidos/urina , Caprilatos/química , Cromatografia Capilar Eletrocinética Micelar/métodos , Fluorocarbonos/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Tensoativos/química , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
J Chromatogr A ; 1267: 138-43, 2012 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-22959866

RESUMO

In this study, in-line frit-free solid-phase extraction (SPE) has been studied for the preconcentration of analytes prior to analysis by capillary electrophoresis-mass spectrometry (CE-MS). The mixed-mode sorbent Oasis HLB was selected for the trapping of compounds of different polarity. Using 2-ethylidene-1,5-dimethyl-3,3-diphenylpirrolidine (EDDP), dihydrocodeine and codeine as test compounds, SPE parameters such as the pH of the sample and composition of the washing and elution solvent were optimized. Trapping of the analytes was optimal at pH 8.0 or higher. For efficient elution of the SPE micro column, 85% of methanol in water with 2% (v/v) acetic acid was used, which also prevented current break down in subsequent CE analysis. CE resolution of the test compounds was highest for background electrolytes (BGEs) with a pH above 8. For optimal analysis, samples were 1:1 diluted with carbonate buffer (1M, pH 8.0) prior to analysis, BGE was 60mM ammonium acetate buffer (pH 10.0), and the injected sample volume was 60 µl (i.e., 30 capillary volumes). Good recoveries were found: 101% for EDDP, 88% for codeine and 90% for dihydrocodeine. Intraday RSDs for migration time and peak areas were below 0.56% and 15%, respectively. Peak widths at half height obtained with SPE-CE-MS were 12s for EDDP, 3.7s for dihydrocodeine and 7.4s for codeine, and were comparable to those for CE-MS. LODs were 0.22 pg/ml for EDDP, 2.1 pg/ml for dihydrocodeine and 24 pg/ml for codeine. It is concluded that the applied fritless in-line preconcentration construct proved to be highly useful for improving the sensitivity of CE while maintaining separation.


Assuntos
Codeína/análogos & derivados , Codeína/química , Eletroforese Capilar/métodos , Espectrometria de Massas/métodos , Extração em Fase Sólida/métodos , Codeína/isolamento & purificação
10.
Int J Pharm ; 416(2): 433-42, 2011 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-21291975

RESUMO

Natural bioactive compounds have been studied for a long time for their chemopreventive and therapeutic potential in several chronic inflammatory diseases, including cancer. However, their physicochemical properties generally result in poor chemical stability and lack of in vivo bioavailability. Very few human clinical trials have addressed absorption, distribution, metabolism, and excretion of these compounds in relation to efficacy. This limits the use of these valuable natural compounds in the clinic. In this study, we examined caffeic acid (derivatives), carvacrol (derivatives), thymol, pterostilbene (derivatives), and N-(3-oxo-dodecanoyl)-l-homoserine lactone. These are natural compounds with strong anti-inflammatory properties derived from plants and bacteria. However, these compounds have poor water solubility or are chemically unstable. To overcome these limitations we have prepared liposomal formulations. Our results show that lipophilic 3-oxo-C(12)-homoserine lactone and stilbene derivatives can be loaded into liposomal lipid bilayer with efficiencies of 50-70%. Thereby, the liposomes solubilize these compounds, allowing intravenous administration without use of solvents. When compounds could not be loaded into the lipid bilayer (carvacrol and thymol) or are rapidly extracted from the liposomes in the presence of serum albumin (3-oxo-C(12)-homoserine lactone and pterostilbene derivatives), derivatization of the compound into a water-soluble prodrug was shown to improve loading efficiency and encapsulation stability. The phosphate forms of carvacrol and pterostilbene were loaded into the aqueous interior of the liposomes and encapsulation was unaffected by the presence of serum albumin. Chemical instability of resveratrol was improved by liposome-encapsulation, preventing inactivating cis-trans isomerization. For caffeic acid, liposomal encapsulation did not prevent oxidation into a variety of products. Still, by derivatization into a phenyl ester, the compound could be stably encapsulated without chemical degradation. Despite the instability of liposome-association of 3-oxo-C(12)-homoserine lactone and resveratrol, intravenous administration of these compounds inhibited tumor growth for approximately 70% in a murine tumor model, showing that simple solubilization can have important therapeutic benefits.


Assuntos
Anti-Inflamatórios/administração & dosagem , Produtos Biológicos/administração & dosagem , Carcinoma de Células Escamosas/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Animais , Anti-Inflamatórios/química , Anti-Inflamatórios/farmacocinética , Produtos Biológicos/química , Produtos Biológicos/farmacocinética , Carcinoma de Células Escamosas/patologia , Estabilidade de Medicamentos , Feminino , Neoplasias de Cabeça e Pescoço/patologia , Lipossomos , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Oxirredução , Solubilidade
11.
Electrophoresis ; 31(14): 2319-27, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20564266

RESUMO

In this study, the usefulness of noncovalently coated capillaries with layers of charged polymers is investigated to obtain global electrophoretic profiles of urinary metabolites covering a broad range of different compound classes in a highly repeatable way. Capillaries were coated with a bilayer of polybrene (PB) and poly(vinyl sulfonate) (PVS), or with a triple layer of PB, dextran sulfate (DS) and PB. The bilayer and triple layer coatings were evaluated at acidic (pH 2.0) and alkaline (pH 9.0) separation conditions, thereby providing separation conditions for basic and acidic compounds. A representative metabolite mixture and spiked urine samples were used for the evaluation of the four CE methods. Migration time repeatability (RSD<2%) and plate numbers (N, 100,000-400,000) were similar for the test compounds in all CE methods, except for some multivalent ions that may exhibit adsorption to oppositely charged coatings. The analysis of cationic compounds with the PB-DS-PB CE method at low pH (i.e. after the EOF time) provided a larger separation window and number of separated peaks in urine compared to the analysis with the PB-PVS CE method at low pH (i.e. before the EOF time). Approximately, 600 molecular features were detected in rat urine by the PB-DS-PB CE-MS method whereas about 300 features were found with the PB-PVS CE-MS method. This difference can be attributed to reduced comigration of compounds with the PB-DS-PB CE-MS method and a related decrease of ion suppression. With regard to the analysis of anionic compounds by CE-MS, in general analyte responses were significantly lower than that for cationic compounds, most probably due to less efficient ionization and to ion suppression effects caused by the background electrolyte. Hence, further optimization is required for the sensitive CE-MS analysis of anionic compounds in body fluids. It is concluded that the selection of a CE method for profiling of cationic metabolites in urine depends on the purpose of the study. For high-throughput analyses, the PB-PVS CE-MS method is favored whereas the PB-DS-PB CE-MS method provides a more information-rich metabolic profile, but at the cost of prolonged analysis time.


Assuntos
Ânions/urina , Cátions/urina , Eletroforese Capilar/métodos , Metaboloma , Metabolômica/métodos , Animais , Espectrometria de Massas/métodos , Ratos , Urina/química
12.
Psychopharmacology (Berl) ; 208(4): 555-62, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20066402

RESUMO

BACKGROUND: In chronic studies, the classical benzodiazepine chlordiazepoxide (CDP) is often the preferred drug because, unlike other benzodiazepines, it is soluble in water. However, rapid CDP hydrolysis in solution has been described. This would diminish plasma levels in chronic minipump studies and introduce the corelease of active compounds. METHODS: Therefore, the present study aimed to explore the putative hydrolysis of CDP in aqueous solution over time and to identify the hydrolysis products. Moreover, we aimed to characterize the hydrolysis products for their in vitro (3H-flunitrazepam binding and oocyte electrophysiology) and in vivo (stress-induced hyperthermia paradigm) GABAA receptor potency. RESULTS: CDP in solution hydrolyzed to the ketone structure demoxepam which was confirmed using mass spectrometry. The hydrolysis was concentration dependent (first-order kinetics) and temperature dependent. CDP exerted greater potency compared to demoxepam in vitro (increased activity at GABAA receptors containing α1 subunits) and in vivo (stress-induced hyperthermia), although 3H-flunitrazepam binding was comparable. CONCLUSIONS: The classical benzodiazepine CDP is rapidly hydrolyzed in solution to the active compound demoxepam which possesses a reduced activity at the GABAA receptor. Chronic studies that use CDP in aqueous solution should thus be interpreted with caution. It is therefore important to consider drug stability in chronic minipump applications.


Assuntos
Benzodiazepinas/farmacologia , Clordiazepóxido/farmacocinética , Bombas de Infusão Implantáveis , Animais , Benzodiazepinas/química , Temperatura Corporal/efeitos dos fármacos , Clordiazepóxido/química , Clordiazepóxido/farmacologia , Cromatografia Líquida/métodos , Estabilidade de Medicamentos , Febre , Hidrólise , Masculino , Espectrometria de Massas/métodos , Camundongos , Camundongos da Linhagem 129 , Oócitos/efeitos dos fármacos , Oócitos/fisiologia , Técnicas de Patch-Clamp/métodos , Ensaio Radioligante/métodos , Receptores de GABA-A/metabolismo , Fatores de Tempo , Trítio
13.
Electrophoresis ; 30(10): 1828-35, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19391148

RESUMO

This paper describes the hyphenation of cIEF and MALDI-TOF MS via a fractionation or spotting device. After focusing in cIEF the compounds are hydrodynamically mobilized and deposited on a MALDI target plate using a sheath liquid interface, which provides the catholyte solution and the electrical ground. From previous experiments, sample conditions that resulted in a high resolution in cIEF and acceptable protein signal intensity in MS were selected [Silvertand et al., Electrophoresis, 2008, 29, 1985-1996]. Besides the mixture of test proteins, the sample solution contains 1% Pharmalyte, 0.3% hydroxyethyl cellulose and 0.1% Tween 20 and is used for both optimization as well as characterization of the cIEF-MALDI-TOF MS system. Hyphenation problems encountered are mainly due to transfer of the liquid from the needle to the MALDI target plate and are solved by choosing the proper sheath catholyte (200 mM NH4OH in 50% methanol with 0.1% Tween20). MS electropherograms were reconstructed by plotting the intensities of the m/z values corresponding to the proteins versus migration time (related to spot number). Reproducibility, peak width and signal intensity for different focusing and spotting (fractionation) times were calculated using these reconstructed MS electropherograms as well as the UV electropherograms. The best results were obtained with focusing time of 75 min (no under- or overfocusing) and a spotting time of 5 s (highest protein signal intensity in MS). The applicability of the system is demonstrated by the analysis of a biopharmaceutical (glucagon) and its deamidation product.


Assuntos
Eletroforese Capilar/instrumentação , Proteínas/análise , Proteômica/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Eletroforese Capilar/métodos , Glucagon/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Espectrofotometria Ultravioleta/métodos
14.
J Chromatogr A ; 1216(18): 4107-12, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-19272607

RESUMO

Recently, oversulfated chondroitin sulfate (OSCS) present in certain lots of heparin was identified as the toxic contaminant responsible for severe side effects following intravenous heparin administration. The United States Pharmacopeia (USP) and European Pharmacopeia (Eur.Ph.) announced an immediate revision of their monographs for heparin sodium by adding two US Food and Drugs Administration-recommended tests for OSCS based on nuclear magnetic resonance and capillary electrophoresis (CE). However, the proposed CE method provides only partial separation of the OSCS contaminant from heparin, thereby hindering appropriate impurity profiling. Here we present an improved CE method that is especially useful for the reliable quantification of OSCS in heparin samples, but also allows determination of the common impurity dermatan sulfate (DS). Parameters such as type and concentration of background electrolyte, capillary temperature, sample concentration and injection volume were investigated and optimized. Enhancement of the OSCS-heparin separation was achieved by using high concentrations of Tris phosphate (pH 3.0) as background electrolyte. High currents and excessive Joule heating were prevented by employing fused-silica capillaries with an internal diameter of 25 microm. Good separations of OSCS, heparin and DS are obtained within 17 min. The method permits injection of relatively high heparin concentrations (up to 50 mg/ml) and large sample volumes (up to 5% of the capillary volume) allowing OSCS and DS determination in heparin down to the 0.05% and 0.5% (w/w) level, respectively. The CE method is shown to be repeatable and linear (R(2)>0.99) for OSCS, heparin and DS. CE analyses of OSCS-contaminated heparin samples and different heparin standards further demonstrate the utility of the method.


Assuntos
Sulfatos de Condroitina/análise , Dermatan Sulfato/análise , Eletroforese Capilar/métodos , Heparina/análise , Contaminação de Medicamentos , Sensibilidade e Especificidade
15.
Electrophoresis ; 29(10): 1985-96, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18409160

RESUMO

Low repeatability of migration time, peak area, and linearity (pI vs. mobilization time) is a problem often encountered in capillary IEF (cIEF) and is mainly caused by protein precipitation and protein-wall interactions. In order to study the influence of these phenomena, the effect of different classes of additives on repeatability of migration time, peak area and linearity of a mixture of seven model proteins has been investigated. Moreover, the influence of these additives on protein signal suppression in MALDI-TOF MS has been studied. The optimal ampholyte blend (stabilizes pH gradient) to be used depends on the selected UV detection wavelength. All tested ampholyte blends show a significant and comparable signal suppression in MS. The best detergent (to prevent precipitation and wall interaction) should be determined for each sample individually, but generally polyethylene oxide and zwitterionic detergents show good repeatability for migration time (RSD <4.5%) and peak area (majority <10%). The RSD of R(2) is <1.3% for the hydrophilic protein mixture. However, these components cause severe signal suppression in MS. Therefore glucoside detergents should preferably be used for MS coupling. Viscosity-increasing agents (for hydrodynamic wall coating and to minimize diffusion) in particular cellulose derivatives, give good repeatability for migration times (RSD <4.5% at lower concentrations), peak area (except for high concentration methylcellulose and hydroxyethylcellulose all within 7.5%), and correlation (pI vs. migration time), but severe signal suppression is observed in MALDI-TOF MS. Overall, cIEF repeatability and linearity can significantly be improved by adding the appropriate components. However, when the system is coupled to a MALDI-TOF MS, compromises have to be made between high repeatability and linearity on one hand and MS signal intensity on the other.


Assuntos
Focalização Isoelétrica/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Detergentes , Eletroforese Capilar/métodos , Eletroforese Capilar/estatística & dados numéricos , Humanos , Concentração de Íons de Hidrogênio , Focalização Isoelétrica/estatística & dados numéricos , Proteínas/química , Proteínas/isolamento & purificação , Reprodutibilidade dos Testes , Solubilidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/estatística & dados numéricos , Viscosidade
16.
Analyst ; 132(1): 75-81, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17180183

RESUMO

The feasibility of using noncovalently bilayer-coated capillaries for capillary electrophoresis-mass spectrometry (CE-MS) of acidic proteins was investigated using background electrolytes (BGEs) of medium pH. The capillary was coated by successively rinsing the capillary with solutions of the oppositely charged polymers polybrene (PB) and poly(vinyl sulfonic acid) (PVS). Volatile BGEs containing ammonium formate and/or N-methyl morpholine were tested at pH 7.5 and 8.5. Overall, these BGEs provided relatively fast protein separations (analysis times of ca. 12 min) and showed high efficiencies (70,000-300,000 plates) when the ionic strength was sufficiently high. Migration-time reproducibilities were very favorable with RSDs of less than 1.0%. Infusion experiments showed satisfactory MS responses for studied proteins dissolved in ammonium formate (pH 8.5), however, high concentrations of N-methyl morpholine appeared to seriously suppress the MS protein signals. Evaluation of the CE-MS system was performed by analyzing a mixture of intact proteins yielding efficient separations and good-quality mass spectra. CE-MS analysis of a reconstituted formulation of the biopharmaceutical recombinant human growth hormone (rhGH) which was stored for a prolonged time, revealed one degradation product which was provisionally identified as desamido rhGH. Based on the MS responses the amount of degradation was estimated to be ca. 25%.


Assuntos
Eletroforese Capilar/métodos , Proteínas/análise , Animais , Eletroforese Capilar/instrumentação , Hormônio do Crescimento Humano/análise , Humanos , Concentração de Íons de Hidrogênio , Análise Espectral/métodos
17.
Electrophoresis ; 27(11): 2091-9, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16736451

RESUMO

The potential of capillaries noncovalently coated with a bilayer of oppositely charged polymers for the analysis of peptides by CE-MS was investigated. Bilayer coatings were produced by subsequently rinsing fused-silica capillaries with a solution of Polybrene (PB) and poly(vinyl sulfonate) (PVS). The PB-PVS coating showed to be fully compatible with MS detection causing no ionization suppression or background signals. The bilayer coating provided a considerable EOF at low pH, thereby facilitating the fast separation of peptides using a BGE of formic acid (pH 2.5). Under optimized CE-MS conditions, for enkephalin peptides high separation efficiencies were obtained with plate numbers in the range of 300,000-500,000. It is demonstrated that both the cancellation of the hydrodynamic capillary flow induced by the nebulizer gas and a sufficiently high-data acquisition rate are crucial for achieving these efficiencies. The overall performance of the CE-MS system using PB-PVS-coated capillaries was evaluated by the analysis of a tryptic digest of cytochrome c. The system provided an efficient separation of the peptide mixture, which could be effectively monitored by MS/MS detection allowing identification of at least 13 peptides within a time interval of 1.5 min. In addition, the PB-PVS coating proved to be very consistent yielding stable CE-MS patterns with highly favorable migration time reproducibilities (RSDs < 1% over a 3-day period).


Assuntos
Eletroforese Capilar/instrumentação , Brometo de Hexadimetrina/química , Espectrometria de Massas/instrumentação , Peptídeos/análise , Polivinil/química , Ácidos Sulfônicos/química , Reprodutibilidade dos Testes
18.
J Clin Endocrinol Metab ; 88(12): 5898-906, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14671188

RESUMO

A disturbed sleep-wake rhythm is common in Alzheimer disease (AD) patients and correlated with decreased melatonin levels and a disrupted circadian melatonin rhythm. Melatonin levels in the cerebrospinal fluid are decreased during the progression of AD neuropathology (as determined by the Braak stages), already in cognitively intact subjects with the earliest AD neuropathology (Braak stages I-II) (preclinical AD). To investigate the molecular mechanisms behind the decreased melatonin levels, we measured monoamines and mRNA levels of enzymes of the melatonin synthesis and its noradrenergic regulation in pineal glands from 18 controls, 33 preclinical AD subjects, and 25 definite AD patients. Pineal melatonin levels were highly correlated with cerebrospinal fluid melatonin levels. The circadian melatonin rhythm disappeared because of decreased nocturnal melatonin levels in both the preclinical AD and AD patients. Also the circadian rhythm of beta(1)-adrenergic receptor mRNA disappeared in both patient groups. The precursor of melatonin, serotonin was stepwise depleted during the course of AD, as indicated by the up-regulated monoamine oxidase A mRNA and activity (5-hydroxyindoleacetic acid:serotonin ratio). We conclude that a dysfunction of noradrenergic regulation and the depletion of serotonin by increased monoamine oxidase A result in the loss of melatonin rhythm already in preclinical AD.


Assuntos
Doença de Alzheimer/metabolismo , Melatonina/metabolismo , Glândula Pineal/metabolismo , Idoso , Doença de Alzheimer/líquido cefalorraquidiano , Doença de Alzheimer/fisiopatologia , Estudos de Casos e Controles , Ritmo Circadiano , Dopamina/metabolismo , Humanos , Ácido Hidroxi-Indolacético/metabolismo , Melatonina/biossíntese , Melatonina/líquido cefalorraquidiano , Monoaminoxidase/genética , Norepinefrina/metabolismo , RNA Mensageiro/metabolismo , Receptores Adrenérgicos beta 1/genética , Serotonina/metabolismo
19.
Analyst ; 128(7): 838-43, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12894819

RESUMO

A method using gas chromatography (GC)-mass spectrometry (MS) for the simultaneous determination of the smoke uptake parameters thiocyanate, nicotine and cotinine in human tissues is reported. Nicotine, cotinine and thiocyanate, in combination with a phase-transfer catalyst, were extracted from urine, saliva and hair into dichloromethane (DCM). Thiocyanate was alkylated in the DCM-layer to form a pentafluorobenzyl derivative. The biochemical markers in DCM were directly injected into the GC system and separated on a DB-1MS column using a 9.4 min temperature program. The method was validated in urine and saliva between the limits of quantitation (1.0-15 microg ml(-1) thiocyanate, 0.010-3.0 microg ml(-1) nicotine and cotinine in urine, 0.010-1.0 microg ml(-1) nicotine and cotinine in saliva). The calibration curves were found to be linear (r > 0.996), the within- and between-day accuracy's were 83-120%, the repeatability coefficients of variation were 3-20% and the limits of detection were 0.060 ng ml(-1) thiocyanate and 0.60 ng ml(-1) nicotine and cotinine. The results of the analysis of the biomarkers in the urine of 44 volunteers were used to develop a predictive model for smoking status, using discriminant analysis. The classification model correctly classified 93.2% of cross-validated grouped cases. Saliva samples were used to confirm the results of the classification method.


Assuntos
Biomarcadores/análise , Fumar/metabolismo , Cotinina/farmacocinética , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cabelo/metabolismo , Humanos , Nicotina/farmacocinética , Saliva/metabolismo , Tiocianatos/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...