Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Viruses ; 15(8)2023 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-37632119

RESUMO

SARS-CoV-2 can be detected in the feces of infected people, consequently in wastewater, and in bivalve mollusks, that are able to accumulate viruses due to their ability to filter large amounts of water. This study aimed to monitor SARS-CoV-2 RNA presence in 168 raw wastewater samples collected from six wastewater treatment plants (WWTPs) and 57 mollusk samples obtained from eight harvesting sites in Campania, Italy. The monitoring period spanned from October 2021 to April 2022, and the results were compared and correlated with the epidemiological situation. In sewage, the ORF1b region of SARS-CoV-2 was detected using RT-qPCR, while in mollusks, three targets-RdRp, ORF1b, and E-were identified via RT-dPCR. Results showed a 92.3% rate of positive wastewater samples with increased genomic copies (g.c.)/(day*inhabitant) in December-January and March-April 2022. In the entire observation period, 54.4% of mollusks tested positive for at least one SARS-CoV-2 target, and the rate of positive samples showed a trend similar to that of the wastewater samples. The lower SARS-CoV-2 positivity rate in bivalve mollusks compared to sewages is a direct consequence of the seawater dilution effect. Our data confirm that both sample types can be used as sentinels to detect SARS-CoV-2 in the environment and suggest their potential use in obtaining complementary information on SARS-CoV-2.


Assuntos
Bivalves , COVID-19 , Humanos , Animais , Águas Residuárias , RNA Viral/genética , SARS-CoV-2/genética , COVID-19/epidemiologia , Itália/epidemiologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-37107807

RESUMO

Legionella is a pathogen that colonizes soils, freshwater, and building water systems. People who are most affected are those with immunodeficiencies, so it is necessary to monitor its presence in hospitals. The purpose of this study was to evaluate the presence of Legionella in water samples collected from hospitals in the Campania region, Southern Italy. A total of 3365 water samples were collected from January 2018 to December 2022 twice a year in hospital wards from taps and showers, tank bottoms, and air-treatment units. Microbiological analysis was conducted in accordance with the UNI EN ISO 11731:2017, and the correlations between the presence of Legionella and water temperature and residual chlorine were investigated. In total, 708 samples (21.0%) tested positive. The most represented species was L. pneumophila 2-14 (70.9%). The serogroups isolated were 1 (27.7%), 6 (24.5%), 8 (23.3%), 3 (18.9%), 5 (3.1%), and 10 (1.1%). Non-pneumophila Legionella spp. represented 1.4% of the total. Regarding temperature, the majority of Legionella positive samples were found in the temperature range of 26.0-40.9 °C. An influence of residual chlorine on the presence of the bacterium was observed, confirming that chlorine disinfection is effective for controlling contamination. The positivity for serogroups other than serogroup 1 suggested the need to continue environmental monitoring of Legionella and to focus on the clinical diagnosis of other serogroups.


Assuntos
Legionella pneumophila , Legionella , Humanos , Cloro/análise , Abastecimento de Água , Hospitais , Monitoramento Ambiental , Água/análise , Microbiologia da Água
3.
Acta Biomed ; 93(3): e2022262, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35775780

RESUMO

BACKGROUND AND AIM: On January 9, 2020, the World Health Organization (WHO) declared that Chinese health authorities had identified a new coronavirus strain never before isolated in humans, the 2019-nCoV later redefined SARS-CoV-2, that still today represent a public health problem. The present survey started on 10 February 2020 with the aim of a) assessing the risk perception in healthcare workers and young students, following the evolution of attitudes, perception and knowledge over time, b) provide useful information to the general population during survey. RESULTS: A study sample consisting of 4116 Italian individuals of both sexes was enrolled. High levels of risk perception, low perception of self-efficacy and low levels of knowledge scores (24.55 ± 5.76 SD) were obtained indicating the need for continuous population monitoring as well as further communication strategies carried out at institution levels. CONCLUSION: The results of the present study could help public health authorities in carrying out informative campaigns for general population and could be an important tool in evaluating public knowledge and misperceptions during the management of the COVID-19. (www.actabiomedica.it).


Assuntos
COVID-19 , Epidemias , Atitude , Feminino , Humanos , Masculino , Saúde Pública , SARS-CoV-2
4.
Nurs Open ; 7(5): 1578-1587, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32802379

RESUMO

Aim: To develop an instrument to investigate knowledge and predictive factors of needlestick and sharps injuries (NSIs) in nursing students during clinical placements. Design: Instrument development and cross-sectional study for psychometric testing. Methods: A self-administered instrument including demographic data, injury epidemiology and predictive factors of NSIs was developed between October 2018-January 2019. Content validity was assessed by a panel of experts. The instrument's factor structure and discriminant validity were explored using principal components analysis. The STROBE guidelines were followed. Results: Evidence of content validity was found (S-CVI 0.75; I-CVI 0.50-1.00). A three-factor structure was shown by exploratory factor analysis. Of the 238 participants, 39% had been injured at least once, of which 67.3% in the second year. Higher perceptions of "personal exposure" (4.06, SD 3.78) were reported by third-year students. Higher scores for "perceived benefits" of preventive behaviours (13.6, SD 1.46) were reported by second-year students.


Assuntos
Ferimentos Penetrantes Produzidos por Agulha , Estudantes de Enfermagem , Estudos Transversais , Humanos , Ferimentos Penetrantes Produzidos por Agulha/epidemiologia , Psicometria , Inquéritos e Questionários
5.
Acta Biomed ; 91(3-S): 165-167, 2020 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-32275284

RESUMO

The aim of this study was to evaluate the correlation between the microbial air contamination values obtained by active sampling (colony-forming units per cubic metre, CFU/m3) and by passive sampling (Index of microbial air contamination, IMA) and to calculate the corresponding equations. Air sampling was performed in ten dental clinics (DC), before (T0), during (T1) and after (T2) the clinical activity, for five consecutive days, once a month for a period of three months, for a total of 450 air samplings. The correlation was evaluated using the Spearman test, and a p value below 0.05 was considered statistically significant. A statistically significant correlation was found considering both the results obtained from the total observations and from the single sampling times, T0, T1 and T2. Different correlation patterns were observed stratifying by DC. Both methods were able to evaluate the microbial air quality and highlight critical situations; therefore, both can be used with this aim. However, in particular during the activity, passive sampling resulted more sensitive, and for its simplicity, economy and standardization by IMA, as suggested by several authors, can be suggested for routine monitoring.


Assuntos
Microbiologia do Ar , Clínicas Odontológicas , Monitoramento Ambiental/métodos , Contagem de Colônia Microbiana , Correlação de Dados
6.
Environ Res ; 164: 574-579, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29625340

RESUMO

BACKGROUND: Legionellosis' treatment failures have been recently reported showing the possibility of resistance development to traditional therapy, especially in healthcare related disease cases. Environmental impact of antibiotic residues, especially in hospital waters, may act on the resistome of Legionella resulting in developing resistance mechanisms. OBJECTIVES: In this study we investigate the antibiotic susceptibility of environmental Legionella pneumophila (Lpn) strains isolated from hospital water systems in Campania, a region located in Southwest Italy. METHODS: 5321 hospital water samples were investigated for the presence of Lpn. Among positive samples, antibiotic susceptibility was tested for a random subset of 125 Lpn strains (25 Lpn isolates from each of the following serogroups: 1, 3, 5, 6, 8). Susceptibility testing was performed, using the E-test on buffered charcoal yeast extract agar supplemented with α-ketoglutarate, for 10 antimicrobial drugs: azithromycin, cefotaxime, clarithromycin, doxycycline, erythromycin, rifampicin, tigecycline, ciprofloxacin, levofloxacin and moxifloxacin. Non parametric tests were used to determine and assess the significant differences in susceptibility to the different antimicrobics between the serogroups. RESULTS: Among the isolated strains, none showed resistance to the antibiotics tested. Rifampicin was the most active antibiotic against overall Legionella strains, followed by levofloxacin. Between the macrolides the clarithromycin was overall the most active drug, instead the azithromycin was the less active. Analyzing the different serogroups a significant difference was found between serogroup 1 and non-1 serogroup isolates for doxycycline and tigecycline. CONCLUSIONS: Antibiotic susceptibility of environmental isolates of Legionella spp. might be useful for the early detection of resistance to antibiotics that directly impacts on mortality and length of hospital stay.


Assuntos
Anti-Infecciosos , Legionella pneumophila , Legionella , Antibacterianos/farmacologia , Monitoramento Ambiental , Itália , Legionella pneumophila/efeitos dos fármacos , Testes de Sensibilidade Microbiana
7.
Food Environ Virol ; 10(2): 187-192, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29248990

RESUMO

Human enteroviruses (HEVs) occur in high concentrations in wastewater and can contaminate receiving environmental waters, constituting a major cause of acute waterborne disease worldwide. In this study, we investigated the relative abundance, occurrence, and seasonal distribution of polio and other enteroviruses at three wastewater treatment plants (WWTPs) in Naples, Southern Italy, from January 2010 to December 2014. Influent and effluent samples from the three WWTPs were collected monthly. One hundred and sixty-one of the 731 wastewater samples collected (22.0%) before and after water treatment were CPE positive on RD cells; while no samples were positive on L20B cells from any WWTPs. Among the 140 non-polio enterovirus isolated from inlet sewage, 69.3% were Coxsackieviruses type B and 30.7% were Echoviruses. Among these, CVB3 and CVB5 were most prevalent, followed by CVB4 and Echo6. The twenty-one samples tested after treatment contained 6 CVB4, 5 CVB3, 3 Echo11, and 2 Echo6; while other serotypes were isolated less frequently. Data on viral detection in treated effluents of WWTPs confirmed the potential environmental contamination by HEVs and could be useful to establish standards for policies on wastewater management.


Assuntos
Infecções por Enterovirus/virologia , Enterovirus/isolamento & purificação , Águas Residuárias/virologia , Purificação da Água/métodos , Humanos , Itália , Poliomielite/virologia , Poliovirus/isolamento & purificação , Esgotos/virologia , Inquéritos e Questionários
8.
Artigo em Inglês | MEDLINE | ID: mdl-28640202

RESUMO

Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®µ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®µ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®µ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®µ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.


Assuntos
Microbiologia do Ar , Legionella pneumophila/genética , Legionella pneumophila/isolamento & purificação , Microbiologia da Água , Poluição da Água , Aerossóis , Poluição do Ar em Ambientes Fechados , Monitoramento Ambiental , Hospitais , Humanos , Itália , Reação em Cadeia da Polimerase em Tempo Real , Medição de Risco , Banheiros
9.
Clin Nutr ; 36(6): 1707-1709, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-27729172

RESUMO

INTRODUCTION: Intestinal bacterial flora plays a central role in human intestinal health and disease. Short Bowel Syndrome (SBS), a clinical condition deriving from extensive bowel resections, influence intestinal microbiota (IM) composition in order to reach a new metabolic balance. Little is known about IM in adult patients after wide intestinal resections. MATERIAL AND METHODS: Fecal samples from 12 SBS patients and 16 controls were analyzed in their microbial profile by using both culture-dependent method and quantitative Real-Time PCR (qRT-PCR). RESULTS: The two methods revealed significant lower concentrations of Bacteroidetes (p-value = .02), Firmicutes (p-value = .05), Bifidobacterium (p-value < .01), and Methanobrevibacter Smithii (p-value = .04) in SBS patients than controls. CONCLUSIONS: The significantly different fecal microbiome in SBS patients compared with healthy controls could open new perspectives on the care of their intestinal functions.


Assuntos
Microbioma Gastrointestinal , Síndrome do Intestino Curto/microbiologia , Adulto , Idoso , Bifidobacterium/isolamento & purificação , Estudos de Casos e Controles , Fezes/microbiologia , Feminino , Firmicutes/isolamento & purificação , Humanos , Intestinos/microbiologia , Lactobacillus/isolamento & purificação , Masculino , Methanobrevibacter/isolamento & purificação , Pessoa de Meia-Idade , Projetos Piloto , Síndrome do Intestino Curto/terapia , Adulto Jovem
10.
J Occup Environ Med ; 58(8): 805-9, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27281711

RESUMO

OBJECTIVE: The aim of this study is to validate the use of the Framingham Risk Score (FRS) as clinical tool to predict the risk of diagnosis of unsuitability for work in a cohort of Italian workers. METHODS: A cohort of workers has been observed from January 2006 to March 2014. FRS was calculated at each visit. Health surveillance diagnosis of unsuitability for work was selected as outcome. RESULTS: Two thousand eight hundred fifty seven workers were observed, 58.9% were men, mean age was 51.6 (±6.7), the mean FRS was 15.1% (±10.7%). Increased values of FRS at baseline were associated with increased rate of diagnosis of unsuitability for work (Hazard ratio [HR], 11.2, 95%CI, 3.3 to 37.8). CONCLUSIONS: FRS is a strong predictor of diagnosis of unsuitability for work and should be used as a clinical tool for the assessment of fitness for work in health surveillance.


Assuntos
Avaliação da Capacidade de Trabalho , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco/métodos , Fatores de Risco
11.
Environ Res ; 146: 47-50, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26717079

RESUMO

BACKGROUND: Legionella is an intracellular microorganism living in natural and artificial aquatic environments. Although its transmission to humans is linked to the inhalation of contaminated aerosols, there is no validated air sampling method for the control and prevention of the disease. The aim of the present study was to provide more information on the distribution of Legionella spp. in indoor environments and to determine whether the same Legionella strains are isolated from air and water samples. METHODS: Ten healthcare facilities located in seven regions of Italy were enrolled. The serological typing of Legionella spp. from water samples and the surrounding air by active and passive sampling was assessed using polyvalent and monovalent antisera. Subsequently, the strains identified as Legionella pneumophila (Lpn) underwent molecular typing by sequence-based typing (SBT) using seven genes (flaA, pilE, asd, mip, mompS, proA, and neuA). The allelic profile number was assigned using the European Working Group for Legionella Infections-SBT database. RESULTS: Lpn serogroup 6 was the most prevalent serogroup; it was found simultaneously in the air and water samples of three different healthcare facilities. In the remaining seven hospitals, Lpn serogroups 1, 6, 7, 9, and 12 were isolated exclusively from water samples. The molecular investigation showed that Lpn strains in the water and air samples of each positive healthcare facility had the same allelic profile. Strains, identified as sequence types (STs) 728 and ST 1638+ST 1324, were isolated in two respective healthcare facilities, and a new strain, identified as ST 1989, was obtained in one healthcare facility. CONCLUSION: The application of the SBT method allowed to verify the homology among Legionella strains from water samples and the surrounding air. The results showed that the same Lpn strains were present in the air and water samples, and a new Legionella strain was identified.


Assuntos
Microbiologia do Ar , Água Potável/microbiologia , Legionella pneumophila/isolamento & purificação , Proteínas de Bactérias/genética , Contagem de Colônia Microbiana , Instalações de Saúde , Itália , Legionella pneumophila/genética , Análise de Sequência de DNA
12.
Ann Ig ; 27(3): 546-53, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26152541

RESUMO

BACKGROUND: Lack of knowledge is the major reason for non-compliance with correct healthcare-associated infections (HAI) prevention procedures. The aim of this study was to evaluate knowledge of the Dental School (DSS) and Dental Hygiene (DHS) students with regard to the prevention of HAI, as basic knowledge for improving and harmonizing the educational content in the different Italian Universities. METHODS: A cross-sectional study was carried out using an anonymous questionnaire that was completed by DSS (I, II, III, IV, and V year) in seven Universities and DHS (I, II, and III year) in three Universities. The questions dealt with three specific areas: healthcare-associated infections, standard precautions and hand hygiene. Factors associated with an unacceptable level of knowledge (score <17.5) were analyzed using a logistic regression model. A p value <0.05 was considered to be significant. RESULTS: Five hundred and four questionnaires were collected: 81.5% for DSS and 18.5% for DHS. Mean overall score (±DS) achieved by the total number of students was 18.2±2.93 on an overall perfect score of 25; 18.2±3.04 for DSS and 17.8±2.31 for DHS. Stratifying by area, the average score 2.7±1.07 (53%) for HAI, 10.3±1.61 (85.9%) for standard precautions, and 5.2±1.44 (64.8%) for hand hygiene was observed. A significantly different level of knowledge (p<0.001) between DSS and DHS was observed only for HAI (2.8±1.07 for DSS vs 2.1±0.96 for DHS). Significant differences among the academic years were found only for DSS concerning HAI and standard precautions. The logistic regression model showed that an age <23 years was a risk factor for lack of knowledge on HAI, but a protective factor for lack of knowledge about standard precautions and hand hygiene; attending DH degree course was associated with lack of knowledge on HAI. CONCLUSIONS: Although the overall score obtained both by DSS and DHS indicated an acceptable level of knowledge, lack of knowledge was highlighted, in particular, for hand hygiene. Therefore, it is necessary to implement and validate effective teaching models in undergraduate courses in order to provide the scientific basis and the theoretical and practical preparation for the prevention and control of HAI.


Assuntos
Infecção Hospitalar/prevenção & controle , Conhecimentos, Atitudes e Prática em Saúde , Controle de Infecções/métodos , Estudantes de Odontologia/estatística & dados numéricos , Adulto , Estudos Transversais , Feminino , Humanos , Itália , Modelos Logísticos , Masculino , Inquéritos e Questionários , Universidades , Adulto Jovem
13.
Neurol Sci ; 36(8): 1457-62, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25809570

RESUMO

The amount of sun exposure in early life and consequent vitamin D3 level may influence the risk of developing Parkinson's disease (PD). Yet few studies have previously investigated birth trends in PD related to a possible seasonality and sun exposure. The aim of this study was to investigate a possible relationship between PD risk and sun exposure looking at seasonal birth variation of PD subjects in the homogenous geographic area of Naples, Italy. We selected 898 PD subjects and matched with 1796 controls. McNemar's test with Bonferroni correction and autocorrelation were used to test seasonality in birth trends. No difference was found for the month and season of birth between PD subjects and controls. We found a 3.3 % increase of PD female subjects born in September (3.3 %) and 4.1 % increase of PD male subjects born in spring comparing to controls but were not significant after Bonferroni correction. This study evaluated for the first time the seasonal birth trends in relation to PD risk in a Southern European population. We found no association between seasonal birth variations and risk of PD.


Assuntos
Doença de Parkinson/epidemiologia , Parto , Estações do Ano , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Estudos Transversais , Surtos de Doenças , Feminino , Humanos , Incidência , Itália , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
Epidemiol Prev ; 38(6 Suppl 2): 62-5, 2014.
Artigo em Italiano | MEDLINE | ID: mdl-25759346

RESUMO

OBJECTIVE: To propose a standardized protocol for the evaluation of Legionella contamination in air. DESIGN: A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. RESULTS: Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). CONCLUSIONS: Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.


Assuntos
Microbiologia do Ar , Poluição do Ar em Ambientes Fechados , Hospitais/estatística & dados numéricos , Legionella/isolamento & purificação , Técnicas de Tipagem Bacteriana , Infecção Hospitalar/prevenção & controle , Monitoramento Ambiental/métodos , Monitoramento Ambiental/normas , Humanos , Itália , Legionella/classificação , Legionella/crescimento & desenvolvimento , Legionelose/prevenção & controle , Banheiros , Eliminação de Resíduos Líquidos , Microbiologia da Água
15.
Sci Total Environ ; 420: 289-99, 2012 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-22335883

RESUMO

A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWSs) reached 872,000cfu/mL. After clinical activity, there was a significant decrease in the Total Viable Count (TVC) in tap water and in DUWSs. Pseudomonas aeruginosa was found in 2.38% (7/294) of tap water samples and in 20.06% (59/294) of DUWS samples; Legionella spp. was found in 29.96% (89/297) of tap water samples and 15.82% (47/297) of DUWS samples, with no significant difference between pre- and post-clinical activity. Microbial air contamination was highest during dental treatments, and decreased significantly at the end of the working activity (p<0.05). The microbial buildup on surfaces increased significantly during the working hours. This study provides data for the establishment of standardized sampling methods, and threshold values for contamination monitoring in dentistry. Some very critical situations have been observed which require urgent intervention. Furthermore, the study emphasizes the need for research aimed at defining effective managing strategies for dental clinics.


Assuntos
Microbiologia do Ar , Clínicas Odontológicas , Monitoramento Ambiental/normas , Contaminação de Equipamentos , Microbiologia da Água , Equipamentos Odontológicos/microbiologia , Humanos , Itália , Níveis Máximos Permitidos
16.
Sci Total Environ ; 408(19): 4045-51, 2010 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-20547411

RESUMO

The dental practice is associated with a high risk of infections, both for patients and healthcare operators, and the environment may play an important role in the transmission of infectious diseases. A microbiological environmental investigation was carried out in six dental clinics as a pilot study for a larger multicentre study that will be performed by the Italian SItI (Society of Hygiene, Preventive Medicine and Public Health) working group "Hygiene in Dentistry". Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days of the week, before and during treatments. Air and surfaces were also examined at the end of the daily activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and relative to the different sampling times. Microbial water contamination in Dental Unit Water Systems (DUWS) reached values of up to 26x10(4)cfu/mL (colony forming units per millilitre). P. aeruginosa was found in 33% of the sampled DUWS and Legionella spp. in 50%. A significant decrease in the Total Viable Count (TVC) was recorded during the activity. Microbial air contamination showed the highest levels during dental treatments and tended to decrease at the end of the working activity (p<0.05). Microbial buildup on surfaces increased significantly during the working hours. As these findings point out, research on microbial environmental contamination and the related risk factors in dental clinics should be expanded and should also be based on larger collections of data, in order to provide the essential knowledge aimed at targeted preventive interventions.


Assuntos
Bactérias/isolamento & purificação , Clínicas Odontológicas/estatística & dados numéricos , Monitoramento Ambiental , Poluentes Ambientais/isolamento & purificação , Contaminação de Equipamentos/estatística & dados numéricos , Contagem de Colônia Microbiana , Humanos , Itália , Legionella/isolamento & purificação , Projetos Piloto , Pseudomonas/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...