Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Comp Eff Res ; 13(4): e230047, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38389409

RESUMO

Aim: Posterior cranial fossa (PCF) surgery is associated with complications, including cerebrospinal fluid (CSF) leakage. Dural sealants such as polyethylene glycol (PEG)-based hydrogels and fibrin glue can prevent CSF leaks, with evidence suggesting PEG hydrogels may outperform fibrin glue. However, the budget impact of using PEG hydrogels in PCF surgeries in Europe is unclear. Materials & methods: A decision tree was developed based on a previous US model, to assess the budget impact of switching from fibrin glue to PEG hydrogel in PCF surgery across five European countries. Input costs were derived from published sources for the financial year 2022/2023. Health outcomes, including CSF leaks, were considered. Results: The model predicted that using PEG hydrogel instead of fibrin glue in PCF surgery can lead to cost savings in five European countries. Cost savings per patient ranged from EUR 419 to EUR 1279, depending on the country. Sensitivity analysis showed that the incidence of CSF leaks and pseudomeningoceles had a substantial impact on the model's results. Conclusion: PEG hydrogels may be a cost-effective alternative to fibrin glue in PCF surgery. The model predicted that cost savings would be mainly driven by a reduction in the incidence of postoperative CSF leaks, resulting in reduced reliance on lumbar drains, reparative surgery and shortened hospital stays.


Assuntos
Rinorreia de Líquido Cefalorraquidiano , Adesivo Tecidual de Fibrina , Humanos , Adesivo Tecidual de Fibrina/uso terapêutico , Procedimentos Neurocirúrgicos/efeitos adversos , Procedimentos Neurocirúrgicos/métodos , Vazamento de Líquido Cefalorraquidiano/prevenção & controle , Vazamento de Líquido Cefalorraquidiano/etiologia , Rinorreia de Líquido Cefalorraquidiano/etiologia , Rinorreia de Líquido Cefalorraquidiano/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Hidrogéis
2.
J Clin Med ; 12(18)2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37762900

RESUMO

Endoscopic procedures are routinely applied to cancer screening programs and surveillance. The preferred technique is usually deep sedation with propofol being a convenient agent allowing for a quicker patient recovery while maintaining a similar safety profile compared to traditional agents. However, adverse events, including respiratory depression and consequent undesirable cardiovascular side effects, may occur. The goal of this work is to evaluate the patient safety impact of adding capnography during endoscopic procedures under deep propofol sedation. Data were retrospectively collected from patients undergoing deep, procedural sedation for gastrointestinal (GI) endoscopy in October 2019 to January 2021 in a single Turkish university hospital. Included in the analysis were all adult patients classified by the American Society of Anesthesiologists (ASA) as I-IV, who were scheduled for GI endoscopy utilizing propofol alone or in combination. Data on 1840 patients were collected, of whom 1610 (730 pre- and 880 post-capnography implemention) met inclusion criteria. The primary outcome was a change in the composite incidence of mild oxygen desaturation (SpO2 75-90% for <60 s), severe oxygen desaturation (SpO2 < 75% anytime or <90% for >60 s), bradycardia (<60 ppm), and tachycardia (>25% from baseline). Without capnography, on average, 7.5 events of the primary endpoint were observed per 100 procedures and 2.9 with additional capnography monitoring (p < 0.001). A significant reduction was observed for mild oxygen desaturation, with a resulting odds ratio of 0.25 (95% CI 0.14 to 0.46). ASA I patients had the highest difference in combined incidence of any oxygen desaturation of 5.85% in the pre-capnography group and 0.64% in the post-capnography group. Although procedural sedation using propofol is not associated with severe adverse events, the incidence of composite adverse events could be reduced with the addition of capnography monitoring.

3.
J Med Econ ; 25(1): 503-514, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35387539

RESUMO

OBJECTIVES: Antiviral treatments for early intervention in patients with mild-to-moderate COVID-19 are needed as a complement to vaccination. We sought to estimate the impact on COVID-19 cases, deaths, and direct healthcare costs over 12 months following introduction of a novel, antiviral treatment, RD-X19, a light-based, at-home intervention designed for the treatment of mild-to-moderate COVID-19 infection. METHODS: A time-dependent, state transition (semi-Markov) cohort model was developed to simulate infection progression in individuals with COVID-19 in 3 US states with varying levels of vaccine uptake (Alabama, North Carolina, and Massachusetts) and at the national level between 1 June 2020 and 31 May 2021. The hypothetical cohort of patients entering the model progressed through subsequent health states after infection. Costs were assigned to each health state. Number of infections/vaccinations per day were incorporated into the model. Simulations were run to estimate outcomes (cases by severity, deaths, and direct healthcare costs) at various levels of adoption of RD-X19 (5%, 10%, 25%) in eligible infected individuals at the state and national levels and across three levels of clinical benefit based on the results from an early feasibility study of RD-X19. The clinical benefit reflects a decline in the duration of symptomatic disease by 1.2, 2.4 (base case), and 3.6 days. RESULTS: In the base case analysis with 10% adoption, simulated infections/deaths/direct healthcare costs were reduced by 10,059/275/$69 million in Alabama, 21,092/545/$135 million in North Carolina, and 16,670/415/$102 million in Massachusetts over 12 months. At the national level, 10% adoption reduced total infections/deaths/direct healthcare costs by 686,722/17,748/$4.41 billion. CONCLUSION: At-home, antiviral treatment with RD-X19 or other interventions with similar efficacy that decrease both symptomatic days and transmission probabilities can be used in concert with vaccines to reduce COVID-19 cases, deaths, and direct healthcare costs.


Assuntos
COVID-19 , Antivirais/uso terapêutico , Análise Custo-Benefício , Custos de Cuidados de Saúde , Humanos , Vacinação
4.
Eur J Gastroenterol Hepatol ; 33(1S Suppl 1): e522-e528, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33905213

RESUMO

OBJECTIVE: Respiratory compromise is a major cause of adverse events during procedural sedation; continuous monitoring is vital for identifying and halting decompensation. We performed a quality improvement investigation to assess patient safety during procedural sedation in gastroenterology and the impact of implementing capnography monitoring. PATIENTS AND METHODS: Sedation-related adverse events and interventions were prospectively recorded during the endoscopic procedure and in recovery. Assuming rates in published literature, power analysis determined that at least 1332 patients were required to show a 20% improvement in patient safety. Recorded sedation-related adverse events (mild and severe oxygen desaturations, bradycardia and tachycardia) and interventions were anonymized and aggregated to evaluate the quality improvement. Patient safety under current care was determined before capnography (Medtronic) was implemented in combination with training. RESULTS: Between February 2018 and April 2018, a baseline (1092 patients) for outcomes under current care was completed, with 11.45 events per 100 procedures recorded. Between May 2018 and July 2018, 1044 procedures including capnography monitoring were performed with 5.08 events per 100 procedures recorded. The distribution of American Society of Anesthesiologists scores and procedure types between baseline and capnography were comparable. The absolute difference between baseline and capnography was -6.4 events per 100 procedures [95% confidence interval (CI), -4.1 to -8.7; P ≤ 0.0001]. The 55% reduction in adverse events surpassed the 20% improvement in patient safety set as the goal of this quality improvement. After multivariate regression, the adjusted odds ratio for events after implementation of capnography was 0.46 (95% CI, 0.32-0.66). CONCLUSIONS: Addition of capnography to current care significantly decreased procedure-related safety events.


Assuntos
Capnografia , Gastroenterologia , Capnografia/métodos , Sedação Consciente/efeitos adversos , Sedação Consciente/métodos , Humanos , Monitorização Fisiológica/métodos , Segurança do Paciente , Melhoria de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...