Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lasers Med Sci ; 29(3): 973-8, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24085595

RESUMO

Thermal relaxation times were introduced into modern skin-laser science with the inception of selective photothermolysis. As a result, laser pulsewidths were determined according to the thermal relaxation times of the tissue targets. The Arrhenius Damage Integral shows that this approach is incorrect. The important parameter is the time required to induce irreversible protein denaturation within the target. This time is determined by the tissue's intrinsic structure, not its physical dimensions. This report explains why thermal relaxation times should not be considered when treating many skin conditions with lasers or IPL systems.


Assuntos
Hipertermia Induzida , Fototerapia , Temperatura , Vasos Sanguíneos/efeitos da radiação , Humanos , Lasers , Pele/efeitos da radiação , Fatores de Tempo
2.
Invest Ophthalmol Vis Sci ; 34(2): 349-54, 1993 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8440588

RESUMO

PURPOSE: The purpose of this study was to measure the transmittance of electromagnetic radiation, particularly visible light, through the ocular media of living and whole rabbit eyes. Previous determinations have been carried out on excised cadaver eyes. METHODS: A specially designed fiberoptic probe (outer diameter, 0.9 mm) was placed in the vitreous in front of the retina using a microsurgical technique. In eight living albino rabbits (under general anesthesia), ocular transmittance was determined in the wavelength range 350 to 1100 nm using a reversed beam path (from vitreous to cornea). RESULTS: A maximum optical transmittance of 94% to 96% (standard deviation, 2%-3%) was found between 630 and 730 nm (reflection losses in the cornea-air interface excluded). In the blue portion of the spectrum, transmittance decreased rapidly for shorter wavelengths, and was 50% at 400 nm and less than 1% at 380 nm. In the infrared part of the spectrum, transmittance was close to 90% up to 900 nm but declined at longer wavelengths, coinciding with the absorption in pure water. Calibration recordings showed a 1% to 2% accuracy of the method. CONCLUSIONS: This experimental technique using an intraocular fiberoptic probe yields a high accuracy and indicates that light transmittance is very high in vivo and superior to that reported from cadaver eyes.


Assuntos
Fenômenos Fisiológicos Oculares , Animais , Humor Aquoso/fisiologia , Córnea/fisiologia , Tecnologia de Fibra Óptica , Raios Infravermelhos , Cristalino/fisiologia , Luz , Coelhos , Espalhamento de Radiação , Raios Ultravioleta , Corpo Vítreo/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...