Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pediatr Pulmonol ; 53(5): 599-604, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29542874

RESUMO

OBJECTIVE: The Cystic Fibrosis Foundation (CFF) recommends routine nebulizer disinfection for patients but compliance is challenging due to the heavy burden of home care. SoClean® is a user friendly ozone based home disinfection device currently for home respiratory equipment. The objective of this study was to determine whether SoClean® has potential as a disinfection device for families with CF by killing CF associated bacteria without altering nebulizer output. HYPOTHESIS: Ozone based disinfection effectively kills bacterial pathogens inoculated to home nebulizer equipment without gross changes in nebulizer function. STUDY DESIGN: Common bacterial pathogens associated with CF were inoculated onto the PariLC® jet nebulizer and bacterial recovery compared with or without varied ozone exposure. In separate experiments, nebulizer output was estimated after repeated ozone exposure by weighing the nebulizer. RESULTS: Ozone disinfection was time dependent with a 5 min infusion time and 120 min dwell time effectively killing >99.99% bacteria tested including Pseudomonas aeruginosa and Staphylococcus aureus. Over 250 h of repeat ozone exposure did not alter nebulizer output. This suggests SoClean® has potential as a user-friendly disinfection technique for home respiratory equipment.


Assuntos
Desinfetantes , Desinfecção/instrumentação , Nebulizadores e Vaporizadores , Ozônio , Carga Bacteriana , Fibrose Cística/microbiologia , Desinfecção/métodos
2.
J Glob Antimicrob Resist ; 7: 114-118, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27750157

RESUMO

Enterobacter spp. have emerged as an important group of pathogens linked to outbreaks in neonatal intensive care units (NICUs), usually involving strains expressing extended-spectrum ß-lactamases (ESBLs). The aim of this study was to describe the first nosocomial bloodstream infection outbreak caused by Enterobacter ludwigii co-harbouring CTX-M-8, SHV-12 and TEM-15 in a NICU in a Venezuelan hospital. Initial bacterial identification was achieved by VITEK®2 system and matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (VITEK® MS) and was subsequently confirmed by nucleotide sequencing of the 16S rDNA gene and hsp60 genotyping. Antimicrobial susceptibility testing was determined by AST-GN-299 VITEK®2 system cards and Etest strips. Isolates were typed by repetitive element sequence-based PCR (rep-PCR). Detection of blaESBL genes was carried out by molecular methods. Plasmid analysis included Southern blot and restriction pattern analysis, with transferability of resistance genes being assessed by conjugation. ESBL-producing E. ludwigii isolates were recovered from three neonates with bloodstream infection from the NICU in a 21-day period. rep-PCR fingerprints were indistinguishable among all of the isolates, strongly suggesting spread of a clonal strain. All isolates carried an ca. 56kb conjugative plasmid harbouring the blaCTX-M-8, blaSHV-12 and blaTEM-15 genes. Considering that isolation of ESBL-producing E. ludwigii remains an unusual phenomenon, not previously reported in Venezuela, the results of this study reveal the potential role of E. ludwigii as an emerging pathogen and highlight the importance of microbiological surveillance and judicious antibiotic use as measures to curb the emergence and spread of ESBL-producing bacteria.


Assuntos
Infecção Hospitalar/microbiologia , Surtos de Doenças , Enterobacter/genética , Unidades de Terapia Intensiva Neonatal , beta-Lactamases/genética , Técnicas de Tipagem Bacteriana , Infecção Hospitalar/epidemiologia , Eletroforese em Gel de Campo Pulsado , Enterobacter/enzimologia , Infecções por Enterobacteriaceae/epidemiologia , Infecções por Enterobacteriaceae/microbiologia , Humanos , Recém-Nascido , Testes de Sensibilidade Microbiana , Venezuela/epidemiologia
3.
Infect Control Hosp Epidemiol ; 37(6): 667-72, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27004524

RESUMO

OBJECTIVE To evaluate ultraviolet C (UV-C) irradiance, UV-C dosage, and antimicrobial effect achieved by a mobile continuous UV-C device. DESIGN Prospective observational study. METHODS We used 6 UV light sensors to determine UV-C irradiance (W/cm2) and UV-C dosage (µWsec/cm2) at various distances from and orientations relative to the UV-C device during 5-minute and 15-minute cycles in an ICU room and a surgical ward room. In both rooms, stainless-steel disks inoculated with methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), and Clostridium difficile spores were placed next to sensors, and UV-C dosages and log10 reductions of target organisms achieved during 5-minute and 15-minute cycles were determined. Mean irradiance and dosage readings were compared using ANOVA. RESULTS Mean UV-C irradiance was nearly 1.0E-03 W/cm2 in direct sight at a distance of 1.3 m (4 ft) from the device but was 1.12E-05 W/cm2 on a horizontal surface in a shaded area 3.3 m (10 ft) from the device (P4 to 1-3 for MRSA, >4 to 1-2 for VRE and >4 to 0 log10 for C. difficile spores, depending on the distance from, and orientation relative to, the device with 5-minute and 15-minute cycles. CONCLUSION UV-C irradiance, dosage, and antimicrobial effect received from a mobile UV-C device varied substantially based on location in a room relative to the UV-C device. Infect Control Hosp Epidemiol 2016;37:667-672.


Assuntos
Desinfecção/métodos , Quartos de Pacientes , Raios Ultravioleta , Clostridioides difficile/efeitos da radiação , Relação Dose-Resposta à Radiação , Staphylococcus aureus Resistente à Meticilina/efeitos da radiação , Estudos Prospectivos , Enterococos Resistentes à Vancomicina/efeitos da radiação
4.
Ann Am Thorac Soc ; 12(6): 859-63, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25849332

RESUMO

RATIONALE: Preventing pulmonary complications during mechanical ventilation via tracheotomy is a high priority. OBJECTIVES: To investigate if the Blom tracheotomy tube with suction-above-the-cuff inner cannula reduced the quantity of normal flora and pathogens in supra- versus subglottic spaces. METHODS: We enrolled 20 consecutive medical ICU adults requiring tracheostomy for mechanical ventilation in this proof-of-concept, prospective, single-center study. All participants received a Blom tracheotomy tube with suction-above-the-cuff inner cannula to decontaminate microorganisms from the supra- and subglottic spaces. Supra- and subglottic sputum samples were obtained for microbiologic analysis while an endotracheal tube was in place before tracheotomy and once per week for up to 4 weeks of mechanical ventilation after tracheotomy. MEASUREMENTS AND MAIN RESULTS: Demographics, duration of endotracheal tube intubation, and duration of mechanical ventilation post-tracheotomy were recorded. There was a significant reduction for supraglottic (2.86 ± 1.11 [mean ± SD]) versus subglottic suction samples (2.48 ± 1.07) (paired t test, P = 0.048; Wilcoxon test, P = 0.045) when all data pairs for normal flora and pathogens were combined across times. There was a significant reduction of normal flora pooled across times in 19 data pairs for supraglottic (3.00 ± 1.05) versus subglottic suction samples (2.00 ± 0.94) (paired t test, P = 0.0004; Wilcoxon test, P = 0.0007). There was no significant reduction of pathogens pooled across times in 25 data pairs for supraglottic (2.76 ± 1.16) versus subglottic suction samples (2.84 ± 1.03) (paired t test, P = 0.75; Wilcoxon test, P = 0.83). CONCLUSIONS: Proof-of-concept was confirmed. The Blom tracheotomy tube with disposable suction-above-the-cuff inner cannula decontaminated microorganisms from the subglottic space when normal flora and pathogens were combined. Future research should investigate if decreased quantity of normal flora and pathogens in the subglottic space reduces the incidence of ventilator-associated pulmonary complications in critically ill patients requiring ongoing mechanical ventilation via tracheotomy.


Assuntos
Controle de Infecções , Laringe/microbiologia , Pneumonia Associada à Ventilação Mecânica , Respiração Artificial/efeitos adversos , Sucção , Traqueotomia/métodos , Adulto , Idoso , Connecticut , Feminino , Humanos , Incidência , Controle de Infecções/métodos , Controle de Infecções/normas , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Pneumonia Associada à Ventilação Mecânica/epidemiologia , Pneumonia Associada à Ventilação Mecânica/etiologia , Pneumonia Associada à Ventilação Mecânica/microbiologia , Pneumonia Associada à Ventilação Mecânica/prevenção & controle , Melhoria de Qualidade , Sucção/instrumentação , Sucção/métodos , Fatores de Tempo
5.
J Clin Microbiol ; 53(1): 113-7, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25355767

RESUMO

Outbreaks and pseudo-outbreaks of infection related to bronchoscopy typically involve Gram-negative bacteria, Mycobacterium species or Legionella species. We report an unusual bronchoscopy-related pseudo-outbreak due to Actinomyces graevenitzii. Extensive epidemiological and microbiological investigation failed to identify a common source. Strain typing revealed that the cluster was comprised of heterogeneous strains of A. graevenitzii. A change in laboratory procedures for Actinomyces cultures was coincident with the emergence of the pseudo-outbreak, and we determined that A. graevenitzii isolates more readily adopted a white, dry, molar tooth appearance on anaerobic colistin nalidixic acid (CNA) agar which likely facilitated its detection and identification in bronchoscopic specimens. This unusual pseudo-outbreak was related to frequent requests of bronchoscopists for Actinomyces cultures combined with a change in microbiology laboratory practices.


Assuntos
Actinomyces/classificação , Actinomicose/epidemiologia , Actinomicose/microbiologia , Broncoscopia/efeitos adversos , Infecção Hospitalar , Contaminação de Equipamentos , Actinomyces/genética , Carga Bacteriana , Estudos de Casos e Controles , Surtos de Doenças , Humanos , Reação em Cadeia da Polimerase , Centros de Atenção Terciária
6.
J Cyst Fibros ; 12(5): 512-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23267773

RESUMO

BACKGROUND: Contaminated nebulizers are a potential source of bacterial infection but no single method is universally accepted for disinfection. We hypothesized that baby-bottle steam sterilizers effectively disinfect home nebulizers. METHODS: Home nebulizers were inoculated with the common CF respiratory pathogens methicillin resistant Staphylococcus aureus, Burkholderia cepacia, Haemophilus influenzae, mucoid and non mucoid Pseudomonas aeruginosa, and Stenotrophomonas maltophilia. The nebulizers were swabbed for bacterial growth, treated with either the AVENT (Philips), the NUK Quick & Ready (Gerber) or DRY-POD (Camera Baby) baby bottle steam sterilizer and reswabbed for bacterial growth. RESULTS: All steam sterilizers were effective at disinfecting all home nebulizers. Viable bacteria were not recovered from any inoculated site after steam treatment, under any conditions tested. CONCLUSIONS: Steam treatment is an effective disinfection method. Additional studies are needed to confirm whether these results are applicable to the clinical setting.


Assuntos
Bactérias , Desinfecção/instrumentação , Equipamentos para Lactente/microbiologia , Nebulizadores e Vaporizadores , Vapor , Esterilização/instrumentação , Alimentação com Mamadeira/instrumentação , Fibrose Cística/microbiologia , Humanos , Lactente , Sistema Respiratório/microbiologia
7.
Conn Med ; 72(3): 139-42, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18426179

RESUMO

A 55-year-old man presented to his primary care provider after a two-week history of worsening cough. He was admitted to the hospital and treated for community acquired pneumonia due to progression of symptoms and an abnormal chest radiograph. Chest computerized tomography demonstrated a large consolidation in the right upper lobe with areas of cavitation consistent with necrosis. Blood and sputum cultures were obtained, and the patient was subsequently diagnosed with pulmonary Salmonella typhimurium infection. The organism was isolated from a sputum specimen only. The patient had a history of chronic alcoholism, bronchitis, and esophageal dysmotility but no evidence of severe immunosuppression or malignancy. The patient responded well to antibiotic therapy with both symptomatic and radiologic improvement. As pulmonary Salmonella infection is exceedingly rare in the immunocompetent patient, a review of the literature is presented.


Assuntos
Infecções Comunitárias Adquiridas/microbiologia , Pneumonia Bacteriana/microbiologia , Infecções por Salmonella/microbiologia , Salmonella typhimurium/isolamento & purificação , Combinação Amoxicilina e Clavulanato de Potássio/uso terapêutico , Antibacterianos/uso terapêutico , Infecções Comunitárias Adquiridas/tratamento farmacológico , Infecções Comunitárias Adquiridas/imunologia , Humanos , Imunocompetência , Masculino , Pessoa de Meia-Idade , Pneumonia Bacteriana/tratamento farmacológico , Pneumonia Bacteriana/imunologia , Infecções por Salmonella/tratamento farmacológico , Infecções por Salmonella/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...