Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 103(18): e37997, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38701272

RESUMO

Very few studies worldwide have assessed the estimated glomerular filtration rate (eGFR) using serum cystatin C (ScysC) in comparison to the gold standard measured glomerular filtration rate (mGFR) with a gamma camera technique using 99m-Technetium-Diethylene Triaminepentoacetic Acid (99mTc-DTPA). To determine the eGFR formula with the most accurate estimate of glomerular filtration rate when compared with mGFR in a healthy population in Vietnam. We conducted a cross-sectional descriptive study of more than 100 adults without hypertension. The study subjects were examined for general characteristics and blood biochemistry tests to assess eGFR, and the glomerular filtration rate was measured using 99mTc-DTPA with the Gates technique to record mGFR. The estimated values of the eGFR formula were evaluated and compared with the actual mGFR using 99mTechnetium-DTPA. Serum creatinine (Scr) concentration showed a significant difference between males and females: 0.9 ±â€…0.1 versus 0.8 ±â€…0.1 (P < .001), while ScysC concentration did not show this difference. The mGFR in the age groups < 40, 40 to 59, and ≥ 60: 105.0 ±â€…9.9, 94.8 ±â€…8.6, and 93.4 ±â€…10.6, respectively (P < .001). The eGFR-CKD-EPI-cystatin C 2012 formula showed the highest positive correlation with mGFR (ΔGFR = -1.6, R = 0.68, P < .001). eGFR calculated using cystatin C does not require sex adjustment, whereas, for creatinine, sex adjustment is necessary. The eGFR-CKD-Epi-CysC formula showed the lowest difference and a strong correlation with mGFR.


Assuntos
Creatinina , Cistatina C , Taxa de Filtração Glomerular , Humanos , Cistatina C/sangue , Feminino , Masculino , Creatinina/sangue , Pessoa de Meia-Idade , Adulto , Estudos Transversais , Vietnã , Pentetato de Tecnécio Tc 99m , Idoso , Biomarcadores/sangue , Compostos Radiofarmacêuticos , População do Sudeste Asiático
2.
Artigo em Inglês | MEDLINE | ID: mdl-38275031

RESUMO

BACKGROUND: Studies have shown the combination treatment effectiveness of using rosuvastatin and ezetimibe in patients with chronic coronary artery disease. Our study aim to evaluate the effectiveness of dyslipidemia treatment with the combination of rosuvastatin and ezetimibe 10mg in patients with chronic coronary artery disease compared with 20 mg rosuvastatin. OBJECTIVES: To evaluate the effectiveness of dyslipidemia treatment with the target of LDL-c < 1.4 mmol/L between combination therapy with rosuvastatin 10 mg and ezetimibe 10 mg in patients with chronic coronary artery disease compared with monotherapy increasing the dose of rosuvastatin 20 mg in Vietnam. METHODS: A randomized controlled clinical trial, single-blind, parallel-group with a 1:1 randomized ratio in 103 outpatients with chronic coronary syndromes treated with rosuvastatin 10mg daily. Group A received the combination therapy with rosuvastatin 10 mg plus ezetimibe 10 mg daily, and group B received rosuvastatin 20 mg daily. The primary outcome was to assess the efficacy of low-density lipoprotein - cholesterol (LDL-c) control between rosuvastatin 10 mg plus ezetimibe 10 mg versus rosuvastatin 20 mg after 4 weeks and 8 weeks. RESULTS: After 8 weeks of intervention, the proportion of archived treatment target patients with LDL-c < 1.4 mmol/L in groups A and B was 69.2% and 44.2%, respectively (Risk ratio (RR) = 1.57, p < 0.01), 50% LDL reduction was 27.9% and 55.8%, respectively (RR = 2.00, p < 0.01), and archived both targets were 51.9% and 25.6% (RR = 2.03, p < 0.01). CONCLUSION: Group A's LDL-c reduction effect and target achievement proportion (Rosuvastatin 10mg + Ezetimibe 10 mg) were significantly higher than Group B's (Rosuvastatin 20 mg). Both medication therapies were safe in patients, and the increased dose of monotherapy showed more side effects than the combination therapy.

3.
Int J Cardiol Cardiovasc Risk Prev ; 19: 200222, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37920809

RESUMO

Background: CYP2C19 gene polymorphism combination with inflammatory cell ratios was significant in the prognosis of coronary heart disease. Materials and methods: A cross-sectional analysis study, with 6 months follow-up on 142 patients with acute coronary syndrome. Patients were analyzed for CYP2C19 gene polymorphisms by real-time polymerase chain reaction (PCR) and complete blood count to determine inflammatory cell ratios and recorded cardiovascular events (CEs) after following up to 6 months. Results: For 90-day CEs, CYP2C19 gene polymorphism (Hazard Ratio (HR): 1.965, 95 % Confidence Interval (CI): 1.012-3.814), the combination of a neutrophil and lymphocyte ratio (NLR) ≥ 2.982 (HR: 13.001, 95 % CI: 1.37-97.304) or a platelet to lymphocyte ratio (PLR) ≥ 162.42 (HR: 2.878, 95 % CI: 1.212-6.835) was independent predictors of CEs. For 180-day CEs, CYP2C19 gene polymorphism combination with NLR ≥3.02 (HR: 13.946, 95 % CI: 1.833-106.121) or PLR ≥160.38 (HR: 5.349, 95 % CI: 1.379-20.745) or monocyte to lymphocyte ratio (MLR) ≥ 0.3 (HR: 4.699, 95 % CI: 1.032-31.393) were independent predictors of CEs. Conclusion: NLR, PLR or MLR combined with CYP2C19 gene polymorphism were stronger independent predictors of cardiovascular events in patients with acute coronary syndromes compared to CYP2C19 gene polymorphism and inflammatory cell ratios separately. CYP2C19 polymorphism and high NLR was the strongest predictor of both CEs at 90 days and 180 days.

4.
Glob Cardiol Sci Pract ; 2023(4): e202326, 2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-38623555

RESUMO

Background: Mitral regurgitation (MR) is a common heart valve disease, causing many serious complications in several organ systems, especially the cardiovascular system. The 2D speckle tracking echocardiography (STE) is a new technique for detecting potential cardiac dysfunction when only tissue function abnormalities are present. The study aimed to assess left ventricular (LV) systolic function early by STE in patients with primary MR through global LV deformity along the global longitudinal strain (GLS). Methods: An analytical cross-sectional study was performed on 46 patients with moderate to severe primary MR as recommended by the American Society of Echocardiography (ASE) 2017. Results: The prevalence of patients with GLS reduction with ejection fraction (EF) >60%, New York Heart Association (NYHA) I, and left ventricular internal diameter systolic (LVIDs) <40 mm was 38.1%, 35.7%, and 39.5%, respectively. 100% of patients with EF<60% and LVIDs ≥40 mm had reduced GLS (<16%). The GLS index strongly correlates with the NYHA classification, degree of MR, EF, and echocardiographic parameters. Conclusion: GLS index gives a significant sign in the early detection of cardiac function abnormalities before symptoms or other echocardiographic parameters in patients with MR.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...