1.
IEEE Rev Biomed Eng ; 16: 439-455, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34543205

RESUMO

Conventional medical instruments are not capable of passing through tortuous anatomy as required for natural orifice transluminal endoscopic surgery due to their rigid shaft designs. Nevertheless, developments in minimally invasive surgery are pushing medical devices to become more dexterous. Amongst devices with controllable flexibility, so-called Follow-The-Leader (FTL) devices possess motion capabilities to pass through confined spaces without interacting with anatomical structures. The goal of this literature study is to provide a comprehensive overview of medical devices with FTL motion. A scientific and patent literature search was performed in five databases (Scopus, PubMed, Web of Science, IEEExplore, Espacenet). Keywords were used to isolate FTL behavior in devices with medical applications. Ultimately, 35 unique devices were reviewed and categorized. Devices were allocated according to their design strategies to obtain the three fundamental sub-functions of FTL motion: steering, (controlling the leader/end-effector orientation), propagation, (advancing the device along a specific path), and conservation (memorizing the shape of the path taken by the device). A comparative analysis of the devices was carried out, showing the commonly used design choices for each sub-function and the different combinations. The advantages and disadvantages of the design aspects and an overview of their performance were provided. Devices that were initially assessed as ineligible were considered in a possible medical context or presented with FTL potential, broadening the classification. This review could aid in the development of a new generation of FTL devices by providing a comprehensive overview of the current solutions and stimulating the search for new ones.


Assuntos
Equipamentos e Provisões , Desenho de Equipamento , Humanos , Movimento (Física)
2.
PLoS One ; 17(9): e0274063, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36070302

RESUMO

Prostate cancer diagnosis and focal laser ablation treatment both require the insertion of a needle for biopsy and optical fibre positioning. Needle insertion in soft tissues may cause tissue motion and deformation, which can, in turn, result in tissue damage and needle positioning errors. In this study, we present a prototype system making use of a wasp-inspired (bioinspired) self-propelled needle, which is able to move forward with zero external push force, thereby avoiding large tissue motion and deformation. Additionally, the actuation system solely consists of 3D printed parts and is therefore safe to use inside a magnetic resonance imaging (MRI) system. The needle consists of six parallel 0.25-mm diameter Nitinol rods driven by the actuation system. In the prototype, the self-propelled motion is achieved by advancing one needle segment while retracting the others. The advancing needle segment has to overcome a cutting and friction force while the retracting needle segments experience a friction force in the opposite direction. The needle self-propels through the tissue when the friction force of the five retracting needle segments overcomes the sum of the friction and cutting forces of the advancing needle segment. We tested the performance of the prototype in ex vivo human prostate tissue inside a preclinical MRI system in terms of the slip ratio of the needle with respect to the prostate tissue. The results showed that the needle was visible in MR images and that the needle was able to self-propel through the tissue with a slip ratio in the range of 0.78-0.95. The prototype is a step toward self-propelled needles for MRI-guided transperineal laser ablation as a method to treat prostate cancer.


Assuntos
Próstata , Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Agulhas , Pelve/patologia , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/patologia
3.
Surg Endosc ; 34(11): 5083-5091, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31811456

RESUMO

BACKGROUND: Three-dimensional (3-D) high-definition (HD) stereovision and two-dimensional (2-D) ultra-high-resolution (4K) monitors have recently become available for laparoscopic surgery. The aim of this study was to compare laparoscopic performance between inexperienced participants using 3-D/HD and 2-D/4K monitors and those using conventional 2-D/HD monitors. METHODS: The study enrolled 66 participants with no previous surgical experience or medical training. They were randomly divided into three equal groups, each using a different type of monitor (2-D/HD, 2-D/4K, or 3-D/HD), to perform three phantom tasks using a laparoscopic simulator: Task 1, touching markers on a non-flat surface; Task 2, bimanual peg transfer; and Task 3, passing a straight rod through a loop. Each task was performed three times. The performance scores (operative time, path length of the forceps, and technical errors) were compared for each monitor type and by age group (< 30 vs. > 30 years). RESULTS: For all three tasks, scores using the 3-D monitor were significantly better than those using either 2-D monitor, with no difference between the 2-D/4K and 2-D/HD monitors. Using the 2-D monitors, the performance of Task 3 by the participants > 30 years was worse than that by the younger participants; however, there was no difference between the age groups when using the 3-D monitor. CONCLUSION: Participants with no prior experience using a 3-D monitor showed better laparoscopic performance than those using 2-D monitors, even with 4K resolution. This improvement was more marked in older participants, suggesting a greater loss of depth perception in a 2-D environment.


Assuntos
Competência Clínica , Avaliação Momentânea Ecológica , Imageamento Tridimensional/métodos , Laparoscopia/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Duração da Cirurgia , Imagens de Fantasmas , Estudos Prospectivos , Instrumentos Cirúrgicos , Análise e Desempenho de Tarefas , Adulto Jovem
4.
Int J Comput Assist Radiol Surg ; 14(9): 1475-1484, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31030387

RESUMO

PURPOSE: Electromagnetic tracking is a core platform technology in the navigation and visualisation of image-guided procedures. The technology provides high tracking accuracy in non-line-of-sight environments, allowing instrument navigation in locations where optical tracking is not feasible. EMT can be beneficial in applications such as percutaneous radiofrequency ablation for the treatment of hepatic lesions where the needle tip may be obscured due to difficult liver environments (e.g subcutaneous fat or ablation artefacts). Advances in the field of EMT include novel methods of improving tracking system accuracy, precision and error compensation capabilities, though such system-level improvements cannot be readily incorporated in current therapy applications due to the 'blackbox' nature of commercial tracking solving algorithms. METHODS: This paper defines a software framework to allow novel EMT designs, and improvements become part of the global design process for image-guided interventions. An exemplary framework is implemented in the Python programming language and demonstrated with the open-source Anser EMT system. The framework is applied in the preclinical setting though targeted liver ablation therapy on an animal model. RESULTS: The developed framework was tested with the Anser EMT electromagnetic tracking platform. Liver tumour targeting was performed using the tracking framework with the CustusX navigation platform using commercially available electromagnetically tracked needles. Ablation of two tumours was performed with a commercially available ablation system. Necropsy of the tumours indicated ablations within 5 mm of the tumours. CONCLUSIONS: An open-source framework for electromagnetic tracking was presented and effectively demonstrated in the preclinical setting. We believe that this framework provides a structure for future advancement in EMT system in and customised instrument design.


Assuntos
Ablação por Cateter/métodos , Fenômenos Eletromagnéticos , Neoplasias Hepáticas/cirurgia , Cirurgia Assistida por Computador/métodos , Algoritmos , Animais , Biópsia por Agulha , Desenho de Equipamento , Feminino , Fígado/cirurgia , Agulhas , Reprodutibilidade dos Testes , Software , Suínos
5.
IEEE Trans Biomed Eng ; 66(6): 1723-1729, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30387716

RESUMO

OBJECTIVE: The goal of this study was to demonstrate the technical feasibility of automated balloon pressure management during resuscitative endovascular balloon occlusion of the aorta (REBOA) in the pre-clinical setting. METHODS: This paper presents an intelligent balloon management device which automates the balloon inflation process, preventing the possibility of balloon over or under inflation, optimizes inflation pressure, and if indicated, deflates automating partial REBOA to allow the distal organ perfusion. Edwards TruWave pressure transducers are used to monitor the blood pressure proximal and distal to the balloon, as well as the internal balloon pressure. A faux PID controller, implemented on an Arduino platform, is used in a feedback control loop to allow a user-defined mean arterial pressure setpoint to be reached, via a syringe driver which allows intelligent inflation and deflation of the catheter balloon. RESULTS: Ex vivo testing on a vascular perfusion simulator provided the characteristic behavior of a fully occluded aorta, namely the decrease of distal pressure to zero. In vivo testing on live porcine models indicated that automated partial REBOA is achievable and by enabling partial occlusion may offer improved medical outcomes compared to the manual control. CONCLUSION: Automated balloon pressure management of endovascular occlusion is feasible and can be successfully implemented without changes on current clinical workflows. SIGNIFICANCE: With further development, automated balloon management may significantly improve clinical outcomes in REBOA.


Assuntos
Aorta/cirurgia , Oclusão com Balão , Procedimentos Endovasculares , Ressuscitação/instrumentação , Animais , Automação/instrumentação , Oclusão com Balão/instrumentação , Oclusão com Balão/métodos , Pressão Sanguínea/fisiologia , Cuidados Críticos , Modelos Animais de Doenças , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Desenho de Equipamento , Retroalimentação , Feminino , Hemorragia/cirurgia , Humanos , Modelos Cardiovasculares , Suínos
6.
Minim Invasive Ther Allied Technol ; 28(6): 363-372, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30428748

RESUMO

Objectives: The goal was to demonstrate the utility of open-source tracking and visualisation tools in the targeting of lung cancer.Material and methods: The study demonstrates the first deployment of the Anser electromagnetic (EM) tracking system with the CustusX image-guided interventional research platform to navigate using an endobronchial catheter to injected tumour targets. Live animal investigations validated the deployment and targeting of peripheral tumour models using an innovative tumour marking routine.Results: Novel tumour model deployment was successfully achieved at all eight target sites across two live animal investigations without pneumothorax. Virtual bronchoscopy with tracking successfully guided the tracked catheter to 2-12 mm from the target tumour site. Deployment of a novel marker was achieved at all eight sites providing a reliable measure of targeting accuracy. Targeting accuracy within 10 mm was achieved in 7/8 sites and in all cases, the virtual target distance at marker deployment was within the range subsequently measured with x-ray.Conclusions: Endobronchial targeting of peripheral airway targets is feasible using existing open-source technology. Notwithstanding the shortcomings of current commercial platforms, technological improvements in EM tracking and registration accuracy fostered by open-source technology may provide the impetus for widespread clinical uptake of electromagnetic navigation in bronchoscopy.


Assuntos
Broncoscopia/métodos , Fenômenos Eletromagnéticos , Neoplasias Pulmonares/diagnóstico , Animais , Feminino , Suínos
7.
Int J Comput Assist Radiol Surg ; 12(6): 1059-1067, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28357627

RESUMO

PURPOSE: Electromagnetic tracking is the gold standard for instrument tracking and navigation in the clinical setting without line of sight. Whilst clinical platforms exist for interventional bronchoscopy and neurosurgical navigation, the limited flexibility and high costs of electromagnetic tracking (EMT) systems for research investigations mitigate against a better understanding of the technology's characterisation and limitations. The Anser project provides an open-source implementation for EMT with particular application to image-guided interventions. METHODS: This work provides implementation schematics for our previously reported EMT system which relies on low-cost acquisition and demodulation techniques using both National Instruments and Arduino hardware alongside MATLAB support code. The system performance is objectively compared to other commercial tracking platforms using the Hummel assessment protocol. RESULTS: Positional accuracy of 1.14 mm and angular rotation accuracy of [Formula: see text] are reported. Like other EMT platforms, Anser is susceptible to tracking errors due to eddy current and ferromagnetic distortion. The system is compatible with commercially available EMT sensors as well as the Open Network Interface for image-guided therapy (OpenIGTLink) for easy communication with visualisation and medical imaging toolkits such as MITK and 3D Slicer. CONCLUSIONS: By providing an open-source platform for research investigations, we believe that novel and collaborative approaches can overcome the limitations of current EMT technology.


Assuntos
Fenômenos Eletromagnéticos , Cirurgia Assistida por Computador/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS